Key Distinctions
Materials may be evaluated by either method, but life-cycle cost analysis is the approach that considers the total cost of an assembly throughout its useful life rather than just initial construction cost.
Gypsum Construction Handbook (7th ed.), Chapter 10 — Selection of MaterialsSTC rates a partition's ability to attenuate sound passing through it, while IIC is a numerical evaluation of a floor-ceiling assembly's effectiveness in retarding impact sound (ASTM E492 testing, ASTM E989 rating).
Gypsum Construction Handbook (7th ed.), Chapter 10 — Fire and Sound TestsNRC measures sound absorption, while CAC applies to ceilings between adjacent spaces.
Gypsum Construction Handbook (7th ed.), Chapter 10 — Fire and Sound TestsASTM E119 (also ANSI/UL 263 and NFPA 251) governs fire resistance testing of building construction and materials, while E90 is sound transmission testing, E413 is STC rating, and E492 is impact sound testing.
Gypsum Construction Handbook (7th ed.), Chapter 10 — Fire and Sound TestsU305 uses a single layer of 5/8" Firecode core panels each side of wood 2x4 studs 16" o.c. with 1-7/8" cement-coated nails at 7" o.c. (insulation optional), while U301 uses two layers each side with base-layer nails 6" o.c. and face-layer 2-3/8" nails 8" o.c., face joints staggered over base joints.
Gypsum Construction Handbook (7th ed.), Chapter 10 — One-Hour Rating, UL Design U305In a 1,850°F fire comparison test the regular 5/8" core failed in 10 to 15 minutes, Type X lasted 45 to 60 minutes, and Type C lasted over 2 hours.
Gypsum Construction Handbook (7th ed.), Chapter 15 — Fire Resistance and Gypsum Panels section5/8" is recommended for the finest single-layer construction with increased fire and sound transmission resistance, while 3/8" is recommended for repair and remodeling over existing surfaces.
Gypsum Construction Handbook (7th ed.), Chapter 2 Framing, Maximum Frame Spacing—Drywall Construction table, footnote (1)1-1/4" Type W screws attach resilient channels to wood studs (nails not recommended), while 1-1/4" Type S oval head screws (or 8d nails) attach steel runners to wood framing and No. 6 Type S bugle head screws attach panels to drywall suspension systems.
Gypsum Construction Handbook (7th ed.), Chapter 2 Framing, Resilient Channel Partitions sectionSteel runners are secured to wood framing with 1-1/4" Type S oval head screws or 8d nails, while runners are attached to concrete and masonry with stub nails or power-driven fasteners.
Gypsum Construction Handbook (7th ed.), Chapter 2 Framing, Runner Installation sectionMix only what can be used within the time on the bag — usually 1 hour for 90 and 2 hours for 210.
Gypsum Construction Handbook (7th ed.), Cladding chapter, Mixing—USG Sheetrock Brand Setting-Type Compounds sectionSuspended acoustical ceiling installation specifies 18 ga. hanger wire for residential work and 12 ga. for commercial work.
Gypsum Construction Handbook (7th ed.), Chapter 9 — Step-By-Step Installation sectionWith perimeter relief, control joints are required when ceiling dimensions exceed 50' in either direction; without perimeter relief, control joints are required when dimensions exceed 30' (maximum 30' intervals).
Gypsum Construction Handbook (7th ed.), Chapter 15 — Building Sciences, Control Joints sectionFor employers with 10 or fewer employees the emergency action plan may be communicated orally and no written plan need be maintained.
OSHA 1926 CFR 29, §1926.35(e)(3)Key Terms
Formulas to Know
Total board SF = partition wall area x 2 (one face each side); example: 12,000 SF of partition x 2 = 24,000 SF of 5/8" boardApproximately 1,000 screws (Type W for wood, Type S or S-12 for steel) per 1,000 SF of gypsum boardWith perimeter relief: control joints where ceiling dimension exceeds 50 ft in either direction; without perimeter relief: control joints at maximum 30 ft intervalsNo. 6 Type S bugle head screws at 8" o.c. at panel periphery and 12" o.c. in the fieldCut one leg and the web of top and bottom steel runners at 2" intervals for the length of the arc, leaving 12" of uncut runner at each end20 or fewer employees = 1 facility minimum (Table D-1)8-hour duration = 90 dBA slow response maximum (Table D-2)