Arkansas Remodeling, Renovations, Restoration, Alterations - Commercial Exam
Arkansas · PSI Services Contractor
Arkansas State Portion 30 questions
Key Distinctions
Detached one- and two-family dwellings and townhouses (each unit from foundation to roof with a separate means of egress) not more than three stories above grade plane, plus accessory structures not more than three stories, may be built under the IRC instead of the building code.
IBC 2015 Chapter 1 — Section 101.2 ScopeBearing support length shall be not less than 1-1/2 inches at exterior wall supports but not less than 3-1/2 inches at interior wall supports.
IRC 2015 Section R505.3.2Glazing area shall be not less than 8 percent of floor area, while the openable area for natural ventilation shall be not less than 4 percent of floor area.
IRC 2015 Section R303.1The 70-percent-of-flat-web-width trigger for replacing or engineering a framing member applies to load-bearing cold-formed steel studs, while the 65-percent figure belongs to reinforcing gable endwall stud holes.
IRC 2015 Section R603.2.6.3Minimum net ventilation opening area is 1 square foot per 150 square feet of under-floor area without a retarder, but may be reduced to 1/1,500 of the under-floor area where an approved Class I vapor retarder covers the ground.
IRC Section R408.2F3 permits a maximum w/cm of 0.40 with minimum 5,000 psi; W1 permits a maximum w/cm of 0.50 with minimum 4,000 psi; S2 permits a maximum w/cm of 0.45 with minimum 4,500 psi.
Contractor's Guide to Quality Concrete Construction (4th ed.), Page 24 (Table 2.5)Under IBC 1803.5.3 the plasticity index must be not less than 15 (ASTM D4318), while 20 is the expansion index threshold under Item 4 and 10 percent is the passing-sieve/particle-size criterion.
IBC 2015 Chapter 18 — Section 1803.5.3 Expansive SoilAISC 360 governs design, fabrication and erection of structural steel elements generally, while AISC 341 governs seismic design and detailing of structures assigned to Seismic Design Category D, E or F.
IBC 2015 Section 2205.1ICC 400 is the standard for design and construction of log structures; AISC 360 applies to structural steel, AISI S100 to cold-formed steel, and AWC WFCM is a separate permitted method for wood-frame construction.
IBC 2015 Section 2302.1Panels permanently exposed in outdoor applications shall be exterior type; the only exception is roof sheathing exposed to the outdoors on the underside, which is permitted to be Exposure 1 type.
IBC 2015 Section 2303.1.5Rafters framed to a ridge board shall be offset not more than 1-1/2 inches from each other; otherwise they must be framed directly opposite each other with a gusset plate used as a tie.
IRC 2015 Section R802.3For employers with 10 or fewer employees the plan may be communicated orally and no written plan need be maintained.
OSHA 1926 CFR 29, §1926.35(e)(3)Basement walls, foundation walls and exterior walls exposed to weather in those R-2/R-3 buildings require f'c not less than 3,000 psi, while nonstructural concrete in Class F0 requires a minimum f'c of 2,500 psi.
IBC 2015 Section 1904.1Fire-resistance-rated assemblies must have joints and fasteners treated, except where the gypsum board receives a decorative finish such as wood paneling, battens or acoustical finishes equivalent to joint treatment.
IBC 2015 Section 2508.5Key Terms
Formulas to Know
Glazing area = floor area x 8% (not less than); worked example: 300 sq ft x 0.08 = 24 sq ft. Openable area for natural ventilation = floor area x 4% (not less than); 300 sq ft x 0.04 = 12 sq ft.Net vent area = 1 sq ft per 150 sq ft of under-floor area (minimum); reduced to 1/1,500 of under-floor area where an approved Class I vapor retarder covers the ground.Resistance = cohesion x contact area, but shall in no case exceed 1/2 x dead load.Required bracing length = tabulated length required for the wall above x 1.15; any adjustment for omitting gypsum wall board on the inside face is taken in addition to this 1.15 increase.Replace or design per accepted engineering practice where hole depth across the web exceeds 70% of the flat width of the web, or hole length exceeds 10 inches or the web depth, whichever is greater.Concealed space area shall not exceed 1,000 sq ft, divided into approximately equal areas.Slope pipe to the outlet or drywell at 1/8 in. per foot (10 mm/m).20 or fewer employees = 1 facility (minimum).Minimum width = 12 in. (300 mm); minimum thickness = 6 in. (150 mm).Formwork = 35 to 60 percent of the total cost of a concrete structure; lateral form pressure is governed by concrete temperature, rate of placement, and weight of concrete.