Exam Cheat Sheet · Quick Reference
Arkansas Residential Builder Exam
Arkansas · PSI Services Contractor
Arkansas State Portion 30 questions
Key Distinctions
The thickened slab area acts like a footing but is formed by a trench dug into the subgrade (strengthened with rebar) rather than by formwork.
Carpentry and Building Construction, Section 11.1, Page 295On architectural drawings HDR abbreviates Header, while HDW is a separate abbreviation meaning Hardware.
Carpentry and Building Construction, Ready Reference Appendix, Page 1024The single-side-cut condition uses a shortening allowance of one-half the 45° thickness of the ridge board, while the double-side-cut condition uses one-half the 45° thickness of a common rafter.
Carpentry and Building Construction, Chapter 18, Page 509Hip and valley rafters should be 2 inches wider in nominal dimension than the common rafters (e.g., 2×8 hips with 2×6 commons) to give full bearing to intersecting jack rafters.
Carpentry and Building Construction, Chapter 18, Page 504Grade SW (Severe Weathering) is highly frost-resistant for brick exposed to freezing weather such as foundation courses and retaining walls; Grade MW is for moderate exposure and Grade NW is for interior backup masonry.
Modern Masonry (9th ed.), Page 116Common bond is a running-bond variation with full-length header courses generally every fifth to seventh course; Flemish alternates headers and stretchers within every course, English alternates full header and stretcher courses, and stack bond is purely a pattern bond with no overlapping.
Modern Masonry (9th ed.), Pages 129-130Class A fires involve wood, paper, cloth, and plastic, while Class B fires involve grease, oil, and chemicals (Class C is electrical equipment and Class D is combustible metals).
Carpentry and Building Construction, Construction Safety & Health, Page 81The number in front of the slash is the maximum support spacing in inches for roof sheathing use; the number after the slash is the maximum spacing for subflooring use.
Carpentry and Building Construction, Section 19.5, Pages 562-563Five bags of cement per cubic yard is the minimum generally acceptable for most work, while six-bag mix is commonly specified where high strength is needed or where steel reinforcement is used.
Carpentry and Building Construction, Section 8.2, Page 226Interior partition walls are typically measured in lineal feet (LF), while floors and roofs are measured in square feet (SF).
Carpentry and Building Construction, Section 2.4, Pages 61-62A theodolite is a transit that reads horizontal and vertical angles electronically on an LCD screen for extremely accurate work, while the builder's level is the least expensive instrument, typically accurate to ±1/4" at 75'.
Carpentry and Building Construction, Chapter 9 — Types of InstrumentsA room-finish schedule lists materials and finishes for floors, walls, and ceilings in each room, while window and door schedules are charts giving rough-opening sizes used during wall layout.
Carpentry and Building Construction, Section 2.3, Page 57Key Terms
Formulas to Know
Excavation length = building length + the specified clearance on each side; width = building width + the same clearance each side; volume = area × 0.259 cu yd per sq ft (factor for a 7-ft depth). Example with 2' clearance: (40+2+2)=44' × (26+2+2)=30' = 1,320 sq ft; 1,320 × 0.259 = 341.88 ≈ 342 cu yd.Board feet = (nominal thickness × nominal width × length in feet) ÷ 12, where one board foot = 1" × 12" × 12". Example: (2 × 10 × 22) ÷ 12 = 36.67 bf per piece; 24 pieces × 36.67 = 880 board feet.One 2×6 board 12 feet long = 12 board feet; 50 boards × 12 bf = 600 board feet.Step 1: floor area = length × width for each level (example: 20' × 40' = 800 sq ft); then apply the board-feet-per-100-sq-ft factor from Table 15-4 and the cost per board foot.(Roof surface area ÷ 100) × 102 bf per 100 sq ft. Example: 2,100 ÷ 100 = 21; 21 × 102 = 2,142 board feet (includes common rafters, hip and valley rafters, ridge boards, and collar ties).Panels = roof area ÷ 32 sq ft per panel, then add 5 percent for trim and waste. Example: 72.19 × 0.05 = 3.6; 72.19 + 3.6 = 75.79, rounded up to 76 sheets.Measure 3 feet along one layout line and 4 feet along the other; the diagonal must read exactly 5 feet for a 90° corner — if not (e.g., 5'-1"), adjust one layout line until it measures 5 feet.Hypotenuse of a right triangle with both short sides = 12" (the common rafter unit run): √(144 + 144) = 16.97 inches, often rounded up to 17 inches.When cripple walls use the same method and tabulated length required for the wall above, multiply the required bracing length by 1.15; any adjustment for omitting gypsum wall board on the inside face is taken in addition to this 1.15 increase.When Hc/Hr (height of ceiling joists or rafter ties to height of roof ridge, both measured vertically above the top of the rafter support walls) = 1/3, multiply the tabulated rafter span by 0.67.