Arkansas State Portion 30 questions
Key Distinctions
A dead load is the total weight of the building including the structural frame and anything permanently attached such as wall coverings, while a live load is weight that is not permanently attached (furniture, people) and is determined by the building's use.
Carpentry and Building Construction, Section 14.1 Framing Systems & Structural Design, Page 383Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories above grade plane with a separate means of egress, and their accessory structures not more than three stories, may comply with the IRC instead of the building code.
IBC 2015 Chapter 1 — Section 101.2 ScopePer 2015 IBC Chapter 2, a mark is an identification applied by the manufacturer showing the manufacturer's name and the function of the product, while a label additionally carries performance characteristics and the identification of an approved agency (a manufacturer's designation indicates compliance with a specified standard or set of rules).
IBC 2015 Chapter 2 — Definitions of 'Mark,' 'Label' and 'Manufacturer's Designation'Tables 2308.7.2(2), (5) and (6) for a ceiling attached to the rafters are based on L/Δ = 240, while the tables for a ceiling not attached to the rafters are based on L/Δ = 180.
IBC 2015 Chapter 23 — Section 2308.7.2 and Tables 2308.7.2(1) through 2308.7.2(6)Floor joist Tables 2308.4.2.1(1) and (2) — covering both the 30 psf sleeping-area and 40 psf living-area live loads — are published at L/Δ = 360, while ceiling joist Tables 2308.7.1(1) and (2) for uninhabitable attics (without storage and with limited storage) are published at L/Δ = 240.
IBC 2015 Chapter 23 — Section 2308.4.2.1 and Tables 2308.4.2.1(1), 2308.4.2.1(2)Per 2015 IBC 1005.3.1 stairway capacity is 0.3 inch per occupant; the reduced 0.2-inch factor applies only to buildings (other than Groups H and I-2) equipped throughout with an automatic sprinkler system AND an emergency voice/alarm communication system.
IBC 2015 Chapter 10 — Section 1005.3.1 StairwaysThe 44-inch minimum stairway width does not override a larger width required by the occupant-load capacity calculation.
IBC 2015 Chapter 10 — Section 1005.3.1 StairwaysOn a stamp such as "32/16," the first number is the maximum spacing of supports in inches for roof sheathing use and the second number is the maximum support spacing for subflooring use.
Carpentry and Building Construction, Section 19.5, Pages 562-563Hip and valley rafters should be 2 inches wider in nominal dimension than the common rafters in the same roof (2×8 hips with 2×6 commons) to give full bearing to intersecting jack rafters.
Carpentry and Building Construction, Chapter 18, Page 504The hip rafter's unit run is the hypotenuse of a right triangle whose two shorter sides each equal the common rafter's 12-inch unit run, giving 16.97 inches (often rounded up to 17 inches).
Carpentry and Building Construction, Section 18.1, Page 506Web holes/punchouts are permitted for utility routing, but a hole must never be punched in the flange because it reduces the member's structural strength.
Carpentry and Building Construction, Section 29.3, Builder's Tip - PunchoutsInterior partition walls are measured in lineal feet (LF), with the cost per lineal foot covering everything from framing to finish, while floors and roofs are measured in square feet (SF).
Carpentry and Building Construction, Section 2.4, Pages 61-62A room-finish schedule lists the materials and finishes for floors, walls and ceilings in each room, while window and door schedules are charts giving rough-opening sizes used for layout and estimating.
Carpentry and Building Construction, Section 2.3, Page 57Key Terms
Formulas to Know
Board feet per piece = (nominal thickness × nominal width × length in feet) ÷ 12; example: 2×10×22' = (2 × 10 × 22) ÷ 12 = 36.67 BF per piece, × 24 pieces ≈ 880 board feetVolume (cu ft) = length × width × depth, then ÷ 27 cu ft per cu yd; example: (40+2+2) × (26+2+2) × 7 = 9,240 cu ft ÷ 27 = 342.2 ≈ 342 cu ydArea of excavation (sq ft) × 0.259 cu yd per sq ft for a 7-foot depth; example: 44' × 30' = 1,320 sq ft × 0.259 = 341.88 ≈ 342 cu yd (excavation adds 2 ft clearance on each side)Required width = occupant load × 0.3 inch per occupant; example: 300 occupants × 0.3 = 90 inches (the 0.2-inch factor applies only to buildings other than Groups H and I-2 with both an automatic sprinkler system and an emergency voice/alarm communication system)Panels = roof area ÷ 32 sq ft per panel, then add 5 percent for trim and waste; example: 72.19 × 0.05 = 3.6; 72.19 + 3.6 = 75.79, rounded up to 76 sheets(Roof surface area ÷ 100) × board feet per 100 sq ft from the table; example: 2,100 ÷ 100 = 21, × 102 BF per 100 sq ft for 2×6 rafters at 16" OC = 2,142 board feetStep 1: Area of floor = length × width for each level (example: 20' × 40' = 800 sq ft); then apply the board-feet-per-100-sq-ft factor from Table 15-4 and the cost per board footMeasure 3 feet along one leg and 4 feet along the other; the diagonal must read exactly 5 feet — if not (e.g., 5'-1"), adjust one layout line until it does before marking remaining exterior walls√(12² + 12²) = √(144 + 144) = 16.97 inches (often rounded up to 17 inches)(1) Determine live load category (e.g., 40 psf); (2) locate species/group column; (3) identify grade column; (4) follow the row right to the required span; (5) follow that column up to the on-center spacing; (6) read lumber dimensions in the row above