Arkansas State Portion 30 questions
Key Distinctions
A dead load is the total weight of the building including the structural frame and anything permanently attached such as wall coverings, while a live load is weight that is not permanently attached (furniture, people) and is determined based on the use of the building.
Carpentry and Building Construction, Section 14.1 Framing Systems & Structural Design, Page 383Hip and valley rafters should be 2 inches wider in nominal dimension than the common rafters in the same roof (e.g., 2×8 hips with 2×6 commons) to give full bearing for the ends of intersecting jack rafters.
Carpentry and Building Construction, Chapter 18, Page 504A common rafter's unit run is 12 inches, while a hip rafter's unit run is the hypotenuse of a right triangle with two 12-inch sides, 16.97 inches (often rounded up to 17 inches).
Carpentry and Building Construction, Section 18.1, Page 506The ridge board is nominal 2" lumber made slightly wider than the rafter stock it supports (e.g., 2×10 ridge with 2×8 rafters) so the angled rafter end cuts bear fully on it.
Carpentry and Building Construction, Section 19.1, Page 530Per IRC 2015 R802.3, rafters framed to a ridge board may be offset not more than 1-1/2 inches from the opposing rafter; alternatively they are framed directly opposite each other with a gusset plate used as a tie.
IRC 2015 Section R802.3The number in front of the slash is the maximum spacing of supports in inches for roof sheathing use; the number after the slash is the maximum support spacing for subflooring use.
Carpentry and Building Construction, Section 19.5, Pages 562-563Per 2015 IRC R303.1, habitable rooms need an aggregate glazing area of not less than 8 percent of floor area, while the openable area for natural ventilation must be not less than 4 percent of floor area.
IRC 2015 Section R303.1A shear wall is a wall designed to resist lateral (sideways) forces, created in part by a specific sheathing nail spacing, while a hold-down anchor is a steel bracket at each corner of the house (or as local codes require) that keeps walls from tipping over during seismic events.
Carpentry and Building Construction, Section 14.1, Page 14-11 (Book Page 378)Holes/punchouts in the web are permitted for utility routing, but a hole must never be punched in the flange of a stud, joist, or track because it reduces structural strength.
Carpentry and Building Construction, Section 29.3, Builder's Tip - PunchoutsIn a unit-cost estimate, interior partition walls are typically measured in lineal feet (LF), while floors and roofs are measured in square feet (SF).
Carpentry and Building Construction, Section 2.4, Pages 61-62Window and door schedules are charts in the plans giving rough-opening sizes used for wall layout, while a room-finish schedule identifies the materials and finishes for floors, walls, and ceilings in each room including hallways.
Carpentry and Building Construction, Section 16.2, Page 440Per OSHA §1926.35(e)(3), employers with 10 or fewer employees may communicate the emergency action plan orally and need not maintain a written plan; otherwise a written plan is maintained.
OSHA 1926 CFR 29, §1926.35(e)(3)Key Terms
Formulas to Know
Board feet per piece = (nominal thickness × nominal width × length in feet) ÷ 12; multiply by number of pieces. Example: (2 × 10 × 22) ÷ 12 = 36.67 bf per piece × 24 pieces ≈ 880 board feet.Add the required clearance to each side of the house dimensions, multiply length × width × depth for cubic feet, then divide by 27 (27 cu ft = 1 cu yd). Example: (40+2+2) × (26+2+2) × 7 = 9,240 cu ft ÷ 27 ≈ 342 cubic yards.Excavated area (sq ft) × 0.259 cu yd per sq ft (standard factor for a 7-foot depth). Example: 44 ft × 30 ft = 1,320 sq ft × 0.259 = 341.88 ≈ 342 cubic yards.Glazing area = not less than 8% of floor area; openable ventilation area = not less than 4% of floor area. Example: 300 sq ft × 0.08 = 24 sq ft glazing; × 0.04 = 12 sq ft openable.Divide total roof area by 32 sq ft per panel, then add 5 percent for trim and waste. Example: 72.19 × 0.05 = 3.6; 72.19 + 3.6 = 75.79, rounded up to 76 sheets.(Roof surface area ÷ 100) × table factor for the member size and spacing. Example: 2×6 rafters at 16" OC = 102 bf per 100 sq ft; 2,100 ÷ 100 = 21; 21 × 102 = 2,142 board feet (includes common rafters, hip and valley rafters, ridge boards, and collar ties).Step 1: Floor area = length × width for each level (example: 20' × 40' = 800 sq ft); then apply the board-feet-per-100-sq-ft factor from Table 15-4 and multiply by the cost per board foot.Measure 3 feet along one layout line and 4 feet along the other; the diagonal must read exactly 5 feet for a 90-degree corner. If it reads otherwise (e.g., 5 ft 1 in.), adjust a layout line until the diagonal is exactly 5 feet.√(12² + 12²) = √(144 + 144) = 16.97 inches (often rounded up to 17 inches), where 12 inches is the common rafter unit run.When cripple walls use the same method and tabulated length as the wall above, multiply the required bracing length by 1.15; any adjustment for omitting gypsum wall board on the inside face is taken in addition to this 1.15 increase.