Exam Cheat Sheet · Quick Reference
ICC F13 Residential Building Contractor (C) Exam (2015 IRC)
National · Pearson Vue
National State Portion 80 questions
Key Distinctions
Both are interlocking metal sheets used as roof covering, but a metal roof panel has an installed weather exposure of not less than 3 square feet per sheet while a metal roof shingle has an installed weather exposure of less than 3 square feet per sheet.
IRC 2015 Section R202 (METAL ROOF PANEL; METAL ROOF SHINGLE)Habitable rooms relying on natural light need an aggregate glazing area of not less than 8 percent of floor area, while the openable area for natural ventilation must be not less than 4 percent of floor area.
IRC 2015 Section R303.1Where a fire sprinkler system per Section P2904 is provided the common wall shall be not less than a 1-hour fire-resistance-rated assembly (ASTM E 119 or UL 263); where no sprinkler system is provided a 2-hour assembly is required.
IRC 2015 Section R302.2Access through the floor to under-floor space shall be a minimum of 18 inches by 24 inches, while an opening through a perimeter wall shall be not less than 16 inches by 24 inches (with a below-grade areaway of the same minimum size).
IRC 2015 Section R408.4Bearing support length shall be not less than 1-1/2 inches at exterior wall supports and not less than 3-1/2 inches at interior wall supports.
IRC 2015 Section R505.3.2Cripple walls braced with the same method and tabulated length as the wall above multiply the required bracing length by 1.15; in addition, in Seismic Design Categories D0 and D1 (and townhouses in Seismic Design Category C), where braced wall lines at interior walls are not supported on a continuous foundation below, the adjacent parallel cripple walls must be braced with Method WSP or CS-WSP with the Table R602.10.3(3) length multiplied by 1.5.
IRC 2015 Section R602.10.11At and below the permitted handrail height the clear width shall be not less than 31-1/2 inches with a handrail on one side and not less than 27 inches with handrails on both sides (36 inches minimum above handrail height; 26 inches is the spiral stairway minimum).
IRC 2015 Section R311.7.1An ionization alarm without a silencing switch shall not be installed less than 20 feet horizontally from a permanently installed cooking appliance, while the distance is 10 feet for an ionization alarm with a silencing switch and 6 feet for a photoelectric alarm.
IRC 2015 Section R314.3.1The general guard limit prohibits passage of a 4-inch sphere, while guards on the open side of stairs may have openings that do not allow passage of a 4-3/8-inch sphere, and the triangular opening formed by riser, tread and bottom rail is limited to a 6-inch sphere.
IRC 2015 Section R312.1.3An addition is an extension or increase in floor area OR height of a building (so adding a second story is an addition), while an alteration is construction other than repair or addition and a repair is renewal of part of a building for maintenance or to correct damage.
IRC 2015 Section R202 (Addition)Labeled means a label, seal, symbol or mark of a nationally recognized testing laboratory or inspection agency that maintains periodic inspection of production has been affixed; listed means inclusion in a published list, and approved means acceptable to the building official.
IRC 2015 Section R202 (Labeled)Where the door swings outward over the landing, the landing or finished floor shall be not more than 1-1/2 inches lower than the top of the threshold; the 7-3/4-inch allowance applies only where the door does not swing over the landing or floor.
IRC 2015 Section R311.3.1A load-bearing steel framing member must be replaced or designed by accepted engineering practice where the hole depth across the web exceeds 70 percent of the flat width of the web (Section R603.2.6.3), while the 65-percent figure applies to reinforcing gable endwall stud holes under Section R603.2.6.2.
IRC 2015 Section R603.2.6.3Key Terms
Formulas to Know
Glazing area = floor area x 0.08 (not less than 8%); worked example: 300 sq ft x 0.08 = 24 sq ftOpenable area = floor area x 0.04 (not less than 4%); worked example: 300 sq ft x 0.04 = 12 sq ftRequired length = tabulated length for the wall above x 1.15; any adjustment for omitting gypsum wall board on the inside face is taken in addition to the 1.15 increaseRequired length = length from Table R602.10.3(3) x 1.5, using Method WSP or CS-WSP (applies only in SDC D0/D1 and townhouses in SDC C)Replace or design by accepted engineering practice where hole depth across web > 70% of the flat width of the web, or the hole length exceeds 10 inches or the web depth, whichever is greaterSlope exceeding 21 units vertical in 12 units horizontal (= 175-percent slope); otherwise not less than 4 fasteners per strip shingle or 2 per individual shingleCapacity not exceeding 5,000 gallons AND ratio of height to diameter or width not exceeding 2 to 1Height measured from bottom of footing to top of wall not over 4 feet, and not supporting a surchargePermit invalid unless work commenced within 180 days of issuance (or suspended/abandoned 180 days after commencement); application deemed abandoned 180 days after filing unless pursued in good faith; building official may grant written extensions of not more than 180 days eachGuard required where the surface is more than 30 inches vertically above the floor or grade below at any point within 36 inches horizontally to the edge of the open side