Exam Cheat Sheet · Quick Reference

ICC F18 Residential Electrician Exam (2014 NEC)

National  ·  Pearson Vue

Verified, not estimated. Every figure below is drawn from the official exam structure we maintain — question counts, passing standard and topic weighting. Practice questions are grounded in the source law with statute citations. We omit any figure we can't verify rather than guess at it.
Total questions
60
Passing score
70%
Exam time
180 min
Administered by
Pearson Vue
Format
Reference materials allowed

National State Portion 60 questions

General Knowledge 7 Q · 12%
Electrical Theory and General Electrical Load CalculationsCode Definitions and TermsNEC Purpose, Scope, and Code ArrangementEquipment Approval, Listing, and Labeling RequirementsGeneral Installation Requirements (Article 110)Working Space and Clearances Around Electrical EquipmentConductor Materials, Sizes, and Temperature RatingsElectrical Symbols and Wiring DiagramsField Terms Versus NEC TermsUnits of Measurement, Conversions, and Basic Math for ElectriciansArticle 110 - Requirements for Electrical InstallationsArticle 100 - Definitions
Services and Service Equipment 13 Q · 22%
Service Load CalculationsService Equipment & Service ConductorsSystem Grounding and BondingService disconnect requirements and ratingsOverhead and underground service conductor installationGrounding electrode system and electrode typesEquipment grounding conductors — types, sizing, and identificationBonding methods at service equipment and piping systemsDemand factors for dwelling unit appliances and cooking equipmentOptional load calculation methods for dwelling unitsArticle 250 - Grounding and BondingArticle 230 - Services
Feeders 8 Q · 13%
Load CalculationsEquipment GroundingFeeder conductor ampacity and minimum sizing (NEC Article 215)Overcurrent protection for feedersFeeder neutral load calculations and permitted reductionsGround-fault protection of equipment on feeders rated 1000A or moreOutside feeder installation requirements (clearances, wiring methods, disconnecting means)Demand factors for dwelling unit appliance loads (dryers, ranges, cooking equipment)Feeder conductor identification (grounded, ungrounded, and equipment grounding conductors)Article 215 - FeedersArticle 225 - Outside Branch Circuits and Feeders
Branch Circuits and Conductors 15 Q · 25%
Branch Circuit CalculationsRequired Outlets & GFCI/AFCI ProtectionOvercurrent ProtectionEquipment GroundingConductorsVoltage Drop Calculations and Conductor SizingConductor Ampacity Tables and Temperature RatingsAmpacity Correction and Adjustment FactorsConductor Insulation Types and ApplicationsGrounded Conductor Identification and UseMultiwire Branch CircuitsBranch-Circuit Voltage Limitations +4 more
Wiring Methods and Materials 8 Q · 13%
Raceway InstallationsBoxes and EnclosuresFlexible Cords and CablesCable Wiring Methods (NM, MC, SE, UF, and Type UF underground installations)Conductor Protection Against Physical Damage (nail plates, clearances, framing members)Underground Installation Requirements and Burial DepthsConduit Fill Calculations and Conductor Count LimitsConduit Bending Techniques (90° stubs, offsets, saddle bends, back-to-back)Securing and Supporting Requirements for Cables and RacewaysCorrosion Protection for Raceways and EnclosuresProtection of Conductors in Vertical RacewaysArticle 348 - Flexible Metal Conduit: Type FMC +3 more
Equipment and Devices 5 Q · 8%
LuminairesReceptacles, Switches and Other DevicesAppliances and Other EquipmentLuminaire location requirements (wet, damp, closets, bathtub/shower zones)Recessed luminaire installation (Type IC vs. non-IC, thermal protection, clearances)Lighting track installation and construction requirementsLow-voltage lighting system requirements (Article 411)Switch ratings, types, and installation requirementsNEMA receptacle and attachment plug configurationsDisconnecting means for appliancesGFCI protection requirements for appliancesArticle 410 - Luminaires, Lampholders, and Lamps +1 more
Special Occupancies, Equipment, and Conditions 4 Q · 7%
Swimming Pools and Similar InstallationsLow Voltage Circuits, Alarm & Similar SystemsFire Alarm Circuit Classifications (NPLFA vs. PLFA) and Power Source RequirementsFire Alarm Cable Types and Installation by Location (FPLP, FPLR, FPL, NPLFP, NPLFR, NPLF)Class 1, Class 2, and Class 3 Circuit Definitions and Power Source LimitationsSeparation and Mixing Rules for Class 2/3 Circuits with Other Circuit TypesCommunications Circuit Wiring Methods, Cable Types (CMP, CMR, CM, CMX), and Installation by LocationPrimary Protector Requirements and Grounding/Bonding for Communications SystemsRadio and Television Antenna Systems: Grounding, Clearances, and Discharge UnitsArticle 680 - Swimming Pools, Fountains, and Similar Installations

Key Distinctions

Service dropvsService lateral / overhead service conductors

A service drop is the overhead conductors between the utility electric supply system and the service point, overhead service conductors run between the service point and the first point of connection to the service-entrance conductors, and a service lateral is the underground equivalent of a service drop.

NEC 2014 Article 100 (Definition: Service Drop)
Exposed (as applied to wiring methods)vsConcealed

Exposed means on or attached to the surface or behind panels designed to allow access, while concealed means rendered inaccessible by the structure or finish of the building.

NEC 2014 Article 100 (Definition: Exposed — as applied to wiring methods)
Wet locationvsDamp location / dry location

Wet locations include installations underground, in concrete slabs or masonry in direct contact with the earth, locations subject to saturation and unprotected locations exposed to weather; roofed open porches and basements with moderate moisture are damp, and a building under construction is a dry location temporarily subject to dampness.

NEC 2014 Article 100 (Definitions: Location, Wet; Location, Damp; Location, Dry)
Single receptaclevsMultiple receptacle

A single receptacle is a single contact device with no other contact device on the same yoke; a multiple receptacle has two or more contact devices on the same yoke (box count, ampere rating and supply circuit are irrelevant to the definition).

NEC 2014 Article 100 (Definition: Receptacle)
Multifamily dwellingvsTwo-family dwelling

A multifamily dwelling is a building containing three or more dwelling units; a building with exactly two units is a two-family dwelling.

NEC 2014 Article 100 (Definition: Dwelling, Multifamily)
AmpacityvsInterrupting rating / short-circuit current rating / demand factor

Ampacity is the maximum current a conductor can carry continuously without exceeding its temperature rating, interrupting rating is the highest current at rated voltage a device is identified to interrupt, short-circuit current rating is the prospective symmetrical fault current an apparatus can be connected to without damage, and demand factor is the ratio of maximum demand to total connected load.

NEC 2014 Article 100 (Definition: Ampacity)
Type 2 SPDvsType 1 / Type 3 / Type 4 SPD

Type 2 SPDs are permanently connected on the load side of the service disconnect overcurrent device (including at a branch panel), Type 1 is on the line side of the service disconnect, Type 3 is at the point of utilization, and Type 4 are component SPDs.

NEC 2014 Article 100 (Definition: Surge-Protective Device)
Multiwire branch circuitvsIndividual / general-purpose / appliance branch circuit

A multiwire branch circuit has two or more ungrounded conductors with voltage between them plus a grounded conductor with equal voltage to each and connected to the system neutral, while an individual branch circuit supplies only one utilization equipment, a general-purpose branch circuit supplies two or more receptacles or outlets for lighting and appliances, and an appliance branch circuit supplies appliance outlets with no permanently connected luminaires.

NEC 2014 Article 100 (Definition: Branch Circuit, Multiwire)
60°C termination rating (circuits 100 A or less)vs75°C conductors for design letter B, C, or D motors

Terminations for equipment on circuits rated 100 amperes or less (or marked for 14 AWG through 1 AWG) use conductors rated 60°C or higher-rated conductors whose ampacity is taken at the 60°C value unless listed/identified otherwise, but for motors marked design letter B, C, or D conductors insulated 75°C (167°F) or higher are permitted provided ampacity does not exceed the 75°C value.

NEC 2014 Section 110.14(C)(1)(a)
Guarding live parts by elevation, 50–300 voltsvsGuarding live parts by elevation, 301–600 volts

Elevation alone requires a minimum of 2.5 m (8 ft) above the floor or working surface for 50 to 300 volts, but 2.6 m (8-1/2 ft) for 301 to 600 volts.

NEC 2014 Section 110.27(A)(4)
Working space depth, 0–150 volts to groundvsWorking space depth, 151–600 volts to ground

For nominal voltage to ground of 0–150 volts the minimum clear working depth is 914 mm (3 ft) for Condition 1, 2, or 3, while the 3 ft 6 in. and 4 ft values belong to the 151–600 volt row.

NEC 2014 Table 110.26(A)(1)
Service equipment in other than dwelling unitsvsDwelling-unit service equipment

Service equipment in other than dwelling units must be legibly field marked with the maximum available fault current and the date of the calculation; dwelling-unit service equipment is not required to carry this marking.

NEC 2014 Section 110.24(A)
Copper conductor constant K = 12.9vsAluminum conductor constant K = 21.2

Aluminum has roughly 1.6 times the resistance of copper, so its voltage-drop K value is 21.2 versus 12.9 for copper.

Key Terms

In Sight From (Within Sight From, Within Sight) NEC 2014 Article 100 (Definition: In Sight From)
Equipment that is visible from and not more than 15 m (50 ft) distant from the other equipment — both conditions must be met.
Continuous Load NEC 2014 Article 100 (Definition: Continuous Load)
A load where the maximum current is expected to continue for 3 hours or more.
Copper-Clad Aluminum Conductors NEC 2014 Article 100 (Definition: Copper-Clad Aluminum Conductors)
Conductors drawn from a copper-clad aluminum rod with copper metallurgically bonded to an aluminum core, the copper forming a minimum of 10 percent of the cross-sectional area of a solid conductor or each strand.
Overcurrent Protective Device, Branch-Circuit NEC 2014 Article 100 (Definition: Overcurrent Protective Device, Branch-Circuit)
A device provided with an interrupting rating appropriate for the intended use but in no case less than 5000 amperes.
Ground-Fault Circuit Interrupter (Class A) NEC 2014 Article 100 (Definition: Ground-Fault Circuit Interrupter)
A device that trips when the current to ground is 6 mA or higher and does not trip when the current to ground is less than 4 mA.
Volatile Flammable Liquid NEC 2014 Article 100 (Definition: Volatile Flammable Liquid)
A flammable liquid with a flash point below 38°C (100°F), a flammable liquid whose temperature is above its flash point, or certain Class II combustible liquids above their flash point.
Separately Derived System NEC 2014 Article 100 (Definition: Separately Derived System)
An electrical source, other than a service, having no direct connection to circuit conductors of any other electrical source other than those established by grounding and bonding connections.
Ampacity NEC 2014 Article 100 (Definition: Ampacity)
The maximum current, in amperes, a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
Concrete-encased electrode (bare copper type) NEC 2014 Section 250.52(A)(3)
At least 20 ft of bare copper conductor not smaller than 4 AWG encased by at least 2 in. of concrete in a footing or foundation in direct contact with the earth.
Rod and pipe electrode NEC 2014 Section 250.52(A)(5)
A grounding electrode not less than 2.44 m (8 ft) in length; rod-type electrodes of stainless steel and copper- or zinc-coated steel must also be at least 5/8 in. in diameter unless listed.
Dedicated electrical space (indoor panelboard) NEC 2014 Section 110.26(E)(1)(a)
The space equal to the width and depth of the equipment extending from the floor to a height of 1.8 m (6 ft) above the equipment or to the structural ceiling, whichever is lower, in which no piping, ducts, or other foreign equipment may be located.
Working space width NEC 2014 Section 110.26(A)(2)
The width of working space in front of electrical equipment must be the width of the equipment or 762 mm (30 in.), whichever is greater, and must permit at least a 90-degree opening of equipment doors or hinged panels.
Interrupting rating requirement (NEC 110.9) NEC 2014 Section 110.9
Equipment intended to interrupt current at fault levels must have an interrupting rating at nominal circuit voltage sufficient for the current available at the line terminals; equipment interrupting at other than fault levels must be rated for the current that must be interrupted.
Lockable disconnecting means NEC 2014 Section 110.25
Where a disconnecting means is required to be lockable open, it must be capable of being locked in the open position and the locking provisions must remain in place with or without the lock installed (cord-and-plug connection locking provisions are excepted).
High leg (4-wire delta, midpoint grounded) NEC 2014 Section 110.15
The conductor or busbar having the higher phase voltage to ground, which must be durably and permanently marked by an orange outer finish or other effective means at each point of connection where the grounded conductor is also present.
THHN insulation designation Conductor insulation type letters (THHN)
T = thermoplastic insulation, HH = high heat resistance (90°C dry), and N = a nylon outer jacket adding abrasion and gasoline/oil resistance.
Branch-circuit ratings (other than individual branch circuits) NEC 2014 Section 210.3
Rated per the maximum permitted rating or setting of the overcurrent device as 15, 20, 30, 40, and 50 amperes (25 amperes is not a recognized rating for these circuits).

Formulas to Know

Single-phase voltage dropVD = (2 × K × I × L) / CM, where K = 12.9 for copper and 21.2 for aluminum, L = one-way length in ft, CM = circular mils; the factor 2 accounts for the out-and-back length of both conductors. Example: (2 × 12.9 × 16 A × 60 ft) / 6,530 cmil = 3.79 V.
Maximum one-way circuit length for a given voltage drop limitAllowable VD = source voltage × percent limit; L = (VD × CM) / (2 × K × I). Example: 240 V × 0.03 = 7.2 V; (7.2 × 16,510) / (2 × 12.9 × 40) = 115 ft one-way.
Minimum conductor size (circular mils) for a voltage drop limitCM = (2 × K × I × L) / VD, then select the smallest standard size with at least that many circular mils. Example: 120 V × 0.03 = 3.6 V; (2 × 12.9 × 20 × 80) / 3.6 = 11,466 cmil → 8 AWG (16,510 cmil).
Percentage voltage drop% VD = voltage drop / source voltage. Example: 8.4 V / 240 V = 3.5 percent (exceeds the 3 percent recommended for a branch circuit alone).
Minimum feeder conductor ampacity (before adjustment/correction factors)Noncontinuous load + 125% of continuous load. Example: 50 A + (30 A × 1.25) = 87.5 A.
Dwelling general load components (Article 220)General lighting = area (sq ft) × 3 VA/sq ft; each small-appliance circuit = 1,500 VA; each laundry circuit = 1,500 VA; sum for total. Example: 2,000 sq ft × 3 = 6,000 VA + (2 × 1,500) + 1,500 = 10,500 VA; per-unit totals are multiplied by the number of units before demand factors (4 × 8,100 VA = 32,400 VA).
Total ampacity of parallel conductor setsPer-conductor table ampacity × number of parallel sets. Example: 350 kcmil copper at 90°C = 350 A; two sets = 700 A.
EMT offset bend marks and shrinkDistance between the two bend marks = multiplier × offset depth (multiplier 1.4 for 45°, e.g., 1.4 × 4 in. = 5-5/8 in.); shrink = shrink-per-inch × offset depth (1/4 in. per in. for the 4-in. offset = 1 in.; 1/2 in. per in. for the 9-in. offset = 4-1/2 in.), and marks move toward the far end by the shrink amount (30 in. + 1 in. = 31 in.).
EMT 90° stub-up bend markMark = stub height − take-up (take-up 5 in. for 1/2" EMT, 6 in. for 3/4" EMT). Examples: 18 − 5 = 13 in.; 12 − 6 = 6 in.
EMT 3-point saddle bendSide marks = 2.5 × obstruction height on each side of the center mark (2.5 × 6 in. = 15 in.); center bent 45°, sides bent 22-1/2°; shrink = 3/16 × obstruction height (3/16 × 6 = 1-1/8 in.).