Exam Cheat Sheet · Quick Reference
ICC F46 Framing Contractor Exam (2015 IBC/IRC)
National · Pearson Vue
National State Portion 50 questions
Key Distinctions
Under IBC 2015 conventional light-frame rules, each joist end needs not less than 1 1/2 inches of bearing on wood or metal, but not less than 3 inches of bearing on masonry.
IBC 2015 Chapter 23 — Section 2308.4.2.2Joists framing from opposite sides of a beam, girder or partition must either be lapped at least 3 inches or the opposing joists tied together in an approved manner.
IBC 2015 Chapter 23 Wood — Section 2308.4.2.3 (Framing Details)Joists or structural floors closer than 18 inches to exposed ground, and girders closer than 12 inches to exposed ground, must be naturally durable or preservative-treated wood.
IBC 2015 Section 2304.12.1.1 (Chapter 23)Before use, fire-retardant-treated wood must be dried to a moisture content of 19 percent or less for lumber and 15 percent or less for wood structural panels.
IBC 2015 Section 2303.2Panels permanently exposed in outdoor applications must be Exterior type, except that wood structural panel roof sheathing exposed to the outdoors on the underside is permitted to be Exposure 1.
IBC 2015 Section 2303.1.5An abandoned permit application may receive one or more written extensions not exceeding 90 days each, while an issued permit may receive written extensions of not more than 180 days each.
IBC 2015 Chapter 1 — Section 105.3.2 Time Limitation of ApplicationA mark is the manufacturer's identification giving the manufacturer's name and the product's function, while a label additionally carries performance characteristics and the identification of an approved agency.
IBC 2015 Chapter 2 — Definitions of 'Mark,' 'Label' and 'Manufacturer's Designation'An approved source is an independent person, firm or corporation approved by the building official and experienced in applying engineering principles to materials, methods or systems analyses, whereas an approved agency is regularly engaged in conducting tests or furnishing inspection services.
IBC 2015 Chapter 2 — Definitions of 'Approved Source' and 'Approved Agency'Lr designates a roof live load of 20 psf or less, while L designates roof live load greater than 20 psf and floor live load.
IBC 2015 Chapter 16 — Section 1602.1 NotationsIBC rafter span tables are based on a deflection limit of L/Δ = 240 where the ceiling is attached to the rafters and L/Δ = 180 where it is not; floor joist span tables use L/Δ = 360.
IBC 2015 Chapter 23 — Section 2308.7.2 and Tables 2308.7.2(1) through 2308.7.2(6)Cripple walls braced with the method and tabulated length of the wall above use a 1.15 multiplier (IRC R602.10.11), while the 1.5 factor applies only to interior cripple walls under unsupported braced wall lines in R602.10.11.1.
IRC 2015 Section R602.10.11Hollow masonry piers are limited to a nominal height of four times the nominal thickness, but where the hollow units are solidly filled with concrete or grout the permitted nominal height is ten times the nominal thickness.
IRC 2015 Section R404.1.9Combustible framing must be not less than 2 inches from flues, chimneys and fireplaces, but 6 inches away from flue openings specifically.
IBC 2015 Section 2304.5 (Chapter 23)Vented under-floor space requires not less than 1 square foot of net ventilation opening per 150 square feet of under-floor area, reduced to 1 square foot per 1,500 square feet where the ground surface is covered with a Class 1 vapor retarder material.
IRC 2015 Sections R408.1 and R408.2Key Terms
Formulas to Know
Value = cost to repair to predamaged condition + cost of other proposed work; compare to more than 50% of predamage market value. Worked example: $70,000 repair + $60,000 addition = $130,000 vs. $240,000 market value → substantial improvement.Area ÷ 150 (no ground cover), or Area ÷ 1,500 where ground is covered with a Class 1 vapor retarder. Worked example: 1,800 sq ft ÷ 1,500 = 1.2 sq ft (vs. 1,800 ÷ 150 = 12 sq ft without the retarder).Height = 4 × nominal thickness (hollow/ungrouted); Height = 10 × nominal thickness where cells are solidly filled with concrete or grout. Worked example: 8-in. nominal grouted pier → 10 × 8 = 80 in. (ungrouted would be 4 × 8 = 32 in.).Required length = tabulated length for the wall above × 1.15; any adjustment for omitting gypsum wall board on the inside face is taken in addition to the 1.15 increase.Length of wood structural panel bracing provided = 1.5 × length required by Table 2308.6.1.Hole diameter permitted up to 40 percent of the stud width; edge of bored hole shall be not nearer than 5/8 inch to the edge of the stud, and holes shall not be at the same section as a cut or notch.Embed bolts not less than 7 inches into concrete or masonry; space not more than 6 feet on center; at least two bolts per piece, located not more than 12 inches and not less than 4 inches from each end.Average dead load 15 psf; floor live load 40 psf; ground snow load shall not exceed 50 psf — exceeding these requires engineered design.Struts not less than 2x4; unbraced strut length shall not exceed 8 feet; strut slope not less than 45 degrees from horizontal; 2x4 purlins span a maximum of 4 feet and 2x6 purlins a maximum of 6 feet.Bearing shall be direct, or provide a sill plate of 2-inch minimum nominal thickness with a minimum nominal bearing area of 48 square inches.