Key Distinctions
A dwelling unit has complete independent living facilities with permanent provisions for living, sleeping, eating, cooking AND sanitation, while a sleeping unit may have living, eating and either sanitation or kitchen facilities but not both.
IBC 2018 Chapter 2 (Definitions), 'Dwelling Unit' and 'Sleeping Unit'NFPA 13R is permitted in Group R occupancies only up to and including four stories and not exceeding 60 feet above grade plane, whereas allowable-area computations with a full NFPA 13 system cap Sa at three stories (four stories only for NFPA 13R per Section 903.3.1.2).
IBC 2018 Page 222Under the double-wall option each townhouse is separated by two 1-hour fire-resistance-rated wall assemblies (ASTM E119, UL 263 or IBC 703.3), while the 1-hour and 2-hour single-wall ratings belong to the common wall option.
IRC 2018 Chapter 3 — Section R302.2.1 (Double walls)A mark is applied by the manufacturer and gives only the manufacturer's name and the product's function; a label additionally carries performance characteristics and the name/identification of an approved agency (and a manufacturer's designation indicates compliance with a specified standard or set of rules).
IBC 2018 Chapter 2 (Definitions), 'Mark'An approved source is an independent person, firm or corporation approved by the building official, competent and experienced in applying engineering principles to materials, methods or systems analyses; an approved agency is one regularly engaged in conducting tests, furnishing inspection services or product certification.
IBC 2018 Chapter 2 (Definitions), 'Approved Source'Labeled means an identifying mark of a nationally recognized testing laboratory or approved agency is affixed and that organization maintains periodic inspection of production; listed means inclusion in a published list, and approved means acceptable to the building official.
IRC 2018 Chapter 2 — Definitions (Labeled, Listed, Approved)Occupant load for fixed seating without dividing arms is not less than one person per 18 inches of seating length, while booths are computed at one person per 24 inches of booth seat length measured at the backrest.
IBC 2018 Page 259Type III can have nearly the same setting times as Type I but develops strength much faster once set — reaching Type I's normal 7-day strength in about 3 days and its normal 28-day strength in about 7 days, with rapid heat of hydration.
Concrete Manual (2015 IBC / ACI 318-14), Chapter 1 — Section 1.2 (The Hydration Reaction)For concrete exposed to sulfate soils or solutions, Type V sulfate-resistant cement should be specified in severe exposures and Type II in moderate exposures (Type III is high-early-strength, not sulfate-resisting).
Concrete Manual (2015 IBC / ACI 318-14), Chapter 4 — Section 4.2 (Deficiencies of the Concrete Itself)The volumetric meter measures air from the change in water column height after agitation, needs no knowledge of batch materials or proportions and may be used in lightweight concrete; the gravimetric method requires specific gravities and batch proportions, and the Chace meter is only an approximation.
Concrete Manual (2015 IBC / ACI 318-14), Chapter 2 — Section 2.8 (Air Content)Controlled-cured cylinders are made to determine compliance with the specifications (ACI 318 26.12.3), while field-cured cylinders are made to determine the time for removal of shoring or forms or when the structure can be placed in service (ACI 318 26.5.3.2).
Concrete Manual (2015 IBC / ACI 318-14), Chapter 3 — Section 3.8 (Job-Molded Specimens)Where a 2-inch minimum nominal sill plate is used, it must provide a minimum nominal bearing area of 48 square inches; direct bearing on masonry or concrete requires not less than 3 inches of bearing.
IRC 2018 Section R802.6A change of occupancy is a change of occupancy classification, a change between groups within a classification, or any change in use within a group that changes the application of code requirements; an increase in floor area is an addition, and a change of ownership alone is neither.
IBC 2018 Chapter 2 (Definitions), 'Change of Occupancy'Key Terms
Formulas to Know
W/C 0.44 by weight × 94 lb/bag = 41.4 lb water; 41.4 lb ÷ 8.33 lb/gal ≈ 5.0 gallons per bag (manual's stated example: W/C = 0.44 = 5 gal/bag)Spacing shall not exceed 30 × slab thickness in both directions, for well-proportioned concrete with aggregates of normal shrinkage, unless reliable data justify wider spacing; panels as nearly square as practical (Concrete Manual 16.2)MSA shall not exceed 1/3 the depth of a slab, 3/4 of the minimum clear spacing between reinforcing bars or between bars and forms, or 1/5 of the narrowest dimension between sides of forms — whichever applies (Concrete Manual 12.3)About 8 pounds (1 gallon) of water per cubic yard for each 10°F rise in concrete temperature (Concrete Manual 19.1)Slump decreases roughly 1/2 to 1 inch for each 10°F rise in concrete temperature (Concrete Manual 2.2)If = [F/P – 0.25] × W/30, applicable only where not less than 25 percent of the building perimeter is on a public way or open space (IBC 506.3.1, Equation 5-5)Sa = actual number of stories above grade plane, not to exceed three for NFPA 13 sprinklered buildings (not to exceed four only for NFPA 13R per 903.3.1.2); no individual story may exceed the area determined using Sa = 1 (IBC 506.2.3, Equation 5-2)Tabulated bracing length (same method as wall above) × 1.15; any gypsum-board-omission adjustment is applied in addition to the 1.15 increase (IRC R602.10.10)Standard 6 × 12 in. cylinder (L/D = 2.0) = 100 percent; a 6-in.-diameter specimen 9 in. long indicates about 104 percent; correction factors for L/D less than 2.0 are applied for direct comparison (Concrete Manual 3.3; ASTM C39, C42)Tensile strength indicated by the splitting tensile test may be as much as 150 percent of the direct tensile strength (Concrete Manual 3.5)