Exam Cheat Sheet · Quick Reference
ICC G25 Journeyman Plumber Exam (2018 IPC)
National · Pearson Vue
National State Portion 70 questions
Key Distinctions
A stack vent is the extension of a soil or waste stack above the highest horizontal drain connected to that stack, while a vent stack is a vertical vent pipe installed primarily to provide circulation of air to and from the drainage system.
IPC 2018 Chapter 2 — Section 202, definitions of Stack Vent and Vent StackA horizontal pipe or fitting makes an angle of less than 45 degrees with the horizontal plane; a vertical pipe or fitting makes an angle of 45 degrees or more with the horizontal (so piping at 40 degrees is horizontal pipe).
IPC 2018 Chapter 2 — Section 202, definitions of Horizontal Pipe and Vertical PipeA plumbing appurtenance is an adjunct device that demands no additional water supply and adds no discharge load to a fixture or the drainage system, whereas devices dependent on energized components are plumbing appliances.
IPC 2018 Chapter 2 — Section 202, definitions of Plumbing Appurtenance and Plumbing ApplianceBoth are prohibited traps, but the S-trap is prohibited with no exception, while drum traps have an exception permitting their use as solids interceptors and for chemical waste systems.
IPC 2018 Section 1002.3Full-open valves are required at locations such as the discharge side of every water meter, the water supply pipe to every water heater, the entrance to the structure, and the base of every water riser pipe (in occupancies other than multiple-family residential two stories or less and one- and two-family dwellings); shutoff valves — not full-open valves — are required at fixture supplies.
IPC 2018 Sections 606.1 and 606.2Urinals shall not be substituted for more than 67 percent of required water closets in assembly and educational occupancies, but not more than 50 percent in all other occupancies.
IPC 2018 Section 424.2The general exception threshold is an occupant load of 15, while Exception 4 waives separate facilities in business occupancies with a maximum occupant load of 25 or fewer; at an occupant load of 30 neither exception applies and separate facilities for each sex are required.
IPC 2018 Section 403.2 Exception 4Potable water-supplied trap seal primer valves conform to ASSE 1018 (1002.4.1.1), waste water-supplied trap primer devices conform to ASSE 1044 (1002.4.1.3), and barrier-type trap seal protection devices conform to ASSE 1072 (1002.4.1.4).
IPC 2018 Section 1002.4.1.1Tempered water has a temperature range between 85°F and 110°F; water at 110°F or greater is defined as hot water.
IPC 2018 Section 202 — definition of 'Tempered Water' (Chapter 2 Definitions)The general minimum floor drain outlet is 2 inches, but rooms containing automatic clothes washers in public coin-operated laundries and central washing facilities of multiple-family dwellings require floor drains with an outlet of not less than 3 inches in diameter.
IPC 2018 Chapter 4 — Section 413.4 Public Laundries and Central Washing FacilitiesPot sinks, prerinse sinks, and floor drains into which kettles are drained are required to discharge through a grease interceptor (1003.3.1), but a food waste disposer shall not discharge to a grease interceptor (1003.3.2).
IPC 2018 Section 1003.3.2Underground exterior water service pipe must have a working pressure rating of not less than 160 psi at 73.4°F, while hot water distribution pipe must have a pressure rating of not less than 100 psi at 180°F.
IPC 2018 Section 605.3Tests required where there is insufficient evidence of product compliance are performed by an approved agency at no expense to the jurisdiction, whereas the permit holder makes the plumbing system tests required by 312/107.4.
IPC 2018 Chapter 1 — Sections 105.3 and 105.3.2 Required Testing/Testing AgencyKey Terms
Formulas to Know
Capacity = 6 cubic feet for the first 100 sq ft of area drained + 1 cubic foot for each additional 100 sq ft. Worked examples: 500 sq ft → 6 + (4 × 1) = 10 cu ft; 400 sq ft → 6 + 3 = 9 cu ft.Assembly and educational occupancies: max urinals = 67% × required water closets (all other occupancies: 50%). Worked example: 6 required WCs × 0.67 = 4.02 → maximum of 4 may be replaced by urinals.Female occupant load = total occupant load ÷ 2; then required WCs = female load ÷ 75 (restaurant ratio 1 per 75 for females). Worked example: 150 ÷ 2 = 75; 75 ÷ 75 = 1 water closet.Fractional numbers from fixture ratios are rounded up to the next whole number; for multiple occupancies, sum the fractional numbers for each occupancy first, then round up.Extend the greater of: 18 inches from the wall surface at each side, OR (outermost front lip projection + 6 inches) measured from the finished backwall surface. Worked example: 14 in lip + 6 = 20 in > 18 in, so 20 inches.For total flow-through ratings greater than 100 gpm, grease retention capacity in pounds = 2 × flow-through rating (the 30-minute multiplier applies instead to sizing gravity grease interceptors under Section 1003.3.7).Low head backpressure ≤ 4.33 psi (29.88 kPa) = pressure exerted by a 10-foot column of water.Threaded CPVC pressure rating = rated pressure reduced by 50 percent; pipe wall thickness must be not less than Schedule 80.Minimum bend radius = not less than 30 pipe diameters, or the minimum coil radius, whichever is greater.Each section tested with not less than a 10-foot head of water, including not less than the upper 10 feet of the next preceding section, so no joint or pipe except the uppermost 10 feet is tested with less than a 10-foot head; hold pressure not less than 15 minutes.