Exam Cheat Sheet · Quick Reference

Idaho Manufactured Housing Installer

Idaho  ·  PSI Services Contractor

Verified, not estimated. Every figure below is drawn from the official exam structure we maintain — question counts, passing standard and topic weighting. Practice questions are grounded in the source law with statute citations. We omit any figure we can't verify rather than guess at it.
Total questions
50
Passing score
70%
Exam time
150 min
Administered by
PSI Services Contractor
Format
Reference materials allowed

Idaho State Portion 50 questions

Idaho Manufactured Home Installation Standard Manual 50 Q · 100%
GeneralAccessory Buildings and StructuresDefinitions and AcronymsPermits and InspectionsGeneral Installation StandardsStandard Set Installation StandardsPermanent Foundation Installation StandardsElectrical ConnectionsPlumbing ConnectionsMechanical ConnectionsUnderfloors, Access and Egress

Key Distinctions

Accessory buildingvsAccessory structure

Accessory buildings include ramadas, storage sheds, and garages, while accessory structures include awnings, carports, decks, steps, and ramps.

Idaho Manufactured Home Installation Standard Manual, Definitions, Item 02 (Page 62)
Installation - "Construction"vsInstallation - "Siting"

Construction is work performed inside the home after it leaves the factory (affecting arrangements/methods of construction, fire and life safety, and electrical, plumbing and mechanical systems), while siting is work performed outside the home to place it on its site, expressly including support and tie-down systems, utility connections, skirting, and steps.

Idaho Manufactured Home Installation Standard Manual, Definitions, Item 32 (Page 64)
Utilities inspection items (204.03)vsInstallation inspection items (204.02)

The utilities inspection covers plumbing connections, fuel gas piping, electrical service, air conditioning, after-market electrical or plumbing equipment, and mechanical equipment, while duct crossovers, flue/chimney/vents, and dryer exhaust ducted through skirting or foundation fall under the installation inspection.

Idaho Manufactured Home Installation Standard Manual, Chapter 2, Subsections 204.02-204.03 (Pages 16-17)
Standard set main frame footing placement (403.01.c)vsPermanent foundation main frame footing placement (503.01.c)

On a standard set, footings and pier stands under the main frame are placed not more than 12 inches from the ends of the frames, while on a permanent foundation set they are placed not more than 30 inches from the ends; both then continue at 6 feet on center.

Idaho Manufactured Home Installation Standard Manual, Chapter 5, Subsection 503.01 (Page 36)
Standard set poured concrete pad footing (402.01.b)vsPermanent foundation poured concrete pad footing (502.01.a)

The minimum poured-in-place individual pad is 4 inches for standard set installations and nominal 8 inches or thicker for permanent foundation installations.

Idaho Manufactured Home Installation Standard Manual, Chapter 5, Subsection 502.01 (Page 34)
Marriage line pier footing, permanent foundation set (503.03.a)vsRidge beam support column footing on a converted standard set home (504.02.d)

The entire marriage line of a permanent foundation set home is supported by minimum 256 square inch poured-in-place footings and piers, while ridge beam support columns on a home converted from standard set to permanent foundation require footings of at least 512 square inches.

Idaho Manufactured Home Installation Standard Manual, Chapter 5, Subsection 503.03 (Page 37)
Single stack concrete block piervsDouble stacked interlocking concrete block pier

Single stack block piers are used for loads not to exceed 5,000 pounds and double stack block piers for loads not to exceed 16,000 pounds; double and single piers may be combined for higher loads.

Idaho Manufactured Home Installation Standard Manual, Chapter 4, Subsection 402.02 (Page 26)
Single stacking height under main frame or marriage linevsSingle stacking height under perimeter walls

Block piers may be single stacked up to 36 inches high under the main frame or marriage line but up to 48 inches high under the perimeter walls; above those heights piers must be double stacked with interlocking blocks.

Idaho Manufactured Home Installation Standard Manual, Chapter 4, Subsection 402.02 (Page 26)
Anchoring equipment allowable working loadvsAnchoring equipment overload test value

Anchors, straps and tension devices must resist an allowable working load equal to or exceeding 3,150 pounds and must withstand a 50% overload of 4,725 pounds without failure of the equipment or attachment point.

Idaho Manufactured Home Installation Standard Manual, Chapter 5, Section 505 (Pages 43-44)
Poured concrete stem wall anchor bolt (504.01.a(3))vsPressure treated wood stem wall bottom plate bolt (504.01.c(1))

A 1/2" x 10" anchor bolt attaches the 2x4 sill plate to a poured concrete stem wall, while a 1/2" x 7" bolt secures the bottom plate of a pressure treated wood stem wall to its footing.

Idaho Manufactured Home Installation Standard Manual, Chapter 5, Subsection 504.01 (Page 39)
Foundation SetvsStandard Set

A Foundation Set is installed on footings and piers with the perimeter enclosed by a supporting permanent foundation footing and stem wall extending below the frost line, while a Standard Set is on footings and piers with the perimeter enclosed by above-ground skirting or fascia.

Idaho Manufactured Home Installation Standard Manual, Definitions, Items 24 and 63 (Pages 63, 67)
Stabilizing devicesvsSupport system / Foundation system / Load bearing device

Stabilizing devices covers ALL components of both the anchoring and support systems (piers, footings, foundations, ties, anchoring equipment, ground anchors), whereas support system covers only foundations, footings, piers, caps and shims, foundation system means a perimeter footing and stem wall support, and a load bearing device is an individual support component.

Idaho Manufactured Home Installation Standard Manual, Definitions, Item 62 (Page 67)
TagvsLabeled

A Tag is a label or insignia issued by the Division and applied to manufactured homes to indicate compliance with federal or state laws, rules and regulations, while Labeled refers to the identifying mark of a nationally recognized testing laboratory or inspection agency on equipment and materials.

Idaho Manufactured Home Installation Standard Manual, Definitions, Items 34, 44 and 65 (Pages 64-67)
RamadavsCarport / Awning

A ramada is a stationary structure with a roof extending over the manufactured home (and possibly a patio or parking space) used principally for protection from snow, sun or rain, while a carport or awning is a roof with its supports and not more than one wall.

Idaho Manufactured Home Installation Standard Manual, Definitions, Item 52 (Page 66)
Installation permit requiredvsInstallation permit not required

Permits are required before installing a home on a building site or in a park, including display homes in parks, subdivisions and residential lots and homes occupied on a sales lot, but are NOT required for unoccupied manufactured homes temporarily displayed on a sales lot or in storage.

Idaho Manufactured Home Installation Standard Manual, Chapter 2, Subsection 201.01 (Page 15)

Key Terms

Approved (Definition 04) Idaho Manufactured Home Installation Standard Manual, Definitions, Items 04 and 17 (Pages 62-63)
Approved, licensed, or certified by the Division of Building Safety or its designee.
Division (Definition 17) Idaho Manufactured Home Installation Standard Manual, Definitions, Items 04 and 17 (Pages 62-63)
The State of Idaho Division of Building Safety.
Testing Laboratory or Testing Agency (Definition 66) Idaho Manufactured Home Installation Standard Manual, Definitions, Items 17 and 66 (Pages 63, 67)
An organization that tests equipment and systems, is qualified to perform testing to approved standards, is independent of any single manufacturer, publishes test reports, and whose methods and standards have been approved by the Division.
Tag (Definition 65) Idaho Manufactured Home Installation Standard Manual, Definitions, Items 34, 44 and 65 (Pages 64-67)
A label or insignia issued by the Division and applied to manufactured homes to indicate compliance with federal or state laws, rules, and regulations.
New Home (Definition 46) Idaho Manufactured Home Installation Standard Manual, Definitions, Item 46 (Page 66)
A manufactured home that has not been titled or converted to real property and/or has not been approved for occupancy by the jurisdiction having authority to do so.
Option (Definition 48) Idaho Manufactured Home Installation Standard Manual, Definitions, Item 48 (Page 66)
A provision made during manufacture of a home to facilitate the future installation of an appliance or other equipment, such as an air conditioner, wet bar, or dishwasher.
Model (Definition 41) Idaho Manufactured Home Installation Standard Manual, Definitions, Item 48 (Page 66)
An individual home designated by the manufacturer with a specific floor plan and equipment per DAPIA-approved plans.
Ground Level Installation (Definition 31) Idaho Manufactured Home Installation Standard Manual, Definitions, Items 24, 31 and 63 (Pages 63-66)
A manufactured home with a below-grade foundation system and a perimeter retaining wall or foundation which has earth backfilled against it.
Foundation Set (Definition 24) Idaho Manufactured Home Installation Standard Manual, Definitions, Items 24, 31 and 63 (Pages 63-66)
A home installed on footings and piers with the perimeter enclosed by a supporting permanent foundation footing and stem wall extending below the frost line.
Standard Set (Definition 63) Idaho Manufactured Home Installation Standard Manual, Definitions, Items 24 and 63 (Pages 63, 67)
A manufactured home installed on footings and piers which has a perimeter enclosed by an above-ground skirting or fascia.
Foundation System (Definition 23) Idaho Manufactured Home Installation Standard Manual, Definitions, Items 23, 24, 62 and 64 (Pages 63, 67)
A perimeter footing and stem wall support system.
Support System (Definition 64) Idaho Manufactured Home Installation Standard Manual, Definitions, Items 23, 24, 62 and 64 (Pages 63, 67)
The combination of foundations, footings, piers, caps, and shims that supports the weight of the home.
Stabilizing Devices (Definition 62) Idaho Manufactured Home Installation Standard Manual, Definitions, Item 62 (Page 67)
All components of the anchoring system and support systems such as piers, footings, foundations, ties, anchoring equipment, ground anchors, and other equipment that supports the home and secures it to the ground.
Load Bearing Device (Definition 36) Idaho Manufactured Home Installation Standard Manual, Definitions, Item 62 (Page 67)
Equipment used in support of the home, limited to footings, piers, caps, and shims.
Tie-Down (Definition 68) Idaho Manufactured Home Installation Standard Manual, Definitions, Item 62 (Page 67)
A single anchoring device.
Recessed Porch (Definition 53) Idaho Manufactured Home Installation Standard Manual, Definitions, Item 53 (Page 66)
An open floor area supported by the main frame which is located outside the exterior walls of the manufactured home.
Ramada (Definition 52) Idaho Manufactured Home Installation Standard Manual, Definitions, Item 52 (Page 66)
A stationary structure having a roof extending over a manufactured home, which may also extend over a patio or parking space, used principally for protection from snow, sun, or rain.
Carport (Definition 12) Idaho Manufactured Home Installation Standard Manual, Definitions, Items 07, 12 and 50 (Pages 62-66)
A stationary structure consisting of a roof with its supports and not more than one wall, used for sheltering a motor vehicle.
Feeder Assembly (Definition 21) Idaho Manufactured Home Installation Standard Manual, Definitions, Items 21 and 58 (Pages 63, 66)
The overhead or under-chassis feeder conductors, including the grounding conductor, together with necessary fittings and equipment, or an approved power supply cord, designed to deliver energy from the electrical supply source to the distribution panelboard in the home.
RME / Responsible Managing Employee (Definition 57) Idaho Manufactured Home Installation Standard Manual, Definitions, Items 39 and 57 (Pages 65-66)
The person designated by the retailer, installer, manufacturer, or resale broker to supervise other employees, either personally or through others.
IDAPA 07.03.12.020 Idaho Manufactured Home Installation Standard Manual, Chapter 2, Subsection 203.01 (Page 15)
The rule for compliance with which local jurisdictions that have adopted a building code (and the Division where none is adopted) issue permits and inspect all manufactured/mobile home installations.

Formulas to Know

Perimeter sidewall footing/pier spacing on a standard set, by roof load (403.02.c)30-40 psf = 8' o.c. max; over 40 up to 60 psf = 6' o.c. max; over 60 up to 80 psf = 4' o.c. max (example: 50 psf → 6' o.c.)
Marriage line rim joist support spacing, STANDARD set with a bearing wall above the marriage line (403.03.d(3))30-40 psf = 8' o.c. max; 41-60 psf = 6' o.c. max; 61-80 psf = 4' o.c. max; over 80 up to 100 psf = 3' o.c. max (example: 90 psf → 3')
Marriage line rim joist support spacing, PERMANENT foundation set with a bearing wall above the marriage line (503.03.d(3))30-40 psf = 8' o.c. max; over 40 up to 60 psf = 6' o.c. max; over 60 up to 80 psf = 4' o.c. max; over 80 up to 100 psf = 3' o.c. max; over 100 psf = 2' o.c. max (example: 75 psf → 4')
Main frame footing/pier stand layoutStandard set: first footing not more than 12" from end of frame, then 6' on center for full frame length (6" variance allowed to clear obstructions); permanent foundation set: not more than 30" from ends, then 6' on center
Anchoring device test load (404.04)Test to 1.5 × horizontal wind load of 15 psf, in combination with 9 psf roof uplift, using ASTM D-3953 procedures
Anchoring equipment capacity (505.02)Allowable working load ≥ 3,150 lbs; must also withstand a 50% overload = 4,725 lbs without failure of equipment or attachment point
Minimum pier support footing area, standard set (402.01)Minimum 256 square inches and not less than the width of the pier supported (equals the nominal 16" x 16" precast pad)
Foundation vent placement (504.01.f)Vent within 3' of each corner and at 20' maximum spacing
Sill plate anchor bolt layout on poured concrete stem wall (504.01.a(3))1/2" x 10" anchor bolts at 6' on center and within 12" of each corner
Stem wall reinforcing (504.01.a(2) and 504.01.b(1))Poured wall: one horizontal #3 bar per 18" of height; stem walls over 30" high also require vertical #3 bar at 32" o.c. tying footing to wall. Block wall: vertical bar in footing within 12" of the ends and at 32" o.c., extending to within 2" of the top of the top course
Basement perimeter wall reinforcing (504.03.b)8" thick concrete wall, minimum 8' and maximum 10' high, reinforced vertically and horizontally every 18" with #4 rebar
Site drain piping grade (704.01/705)1/4" per foot; may be reduced to 1/8" per foot where a full-size cleanout is installed at the upper end
Pier height over 36" limit, permanent foundation (503.05)No more than 25% of main frame pier supports may exceed 36" in height without prior approval of the local authority having jurisdiction (unless the home is set on a basement)
Concrete curing and strength (303.01.b)Poured-in-place concrete shall cure at least 4 days before installing the home and reach compressive strength of not less than 2,500 psi in 28 days