Kansas General Building Contractor (A) Exam (ICC 550, 2015 IBC)
Kansas · Pearson Vue
Kansas State Portion 90 questions
Key Distinctions
A mark is an identification applied by the manufacturer showing only the manufacturer's name and the product's function, while a label additionally carries performance characteristics and the identification of an approved agency (a manufacturer's designation indicates compliance with a specified standard or set of rules).
IBC 2015 Chapter 2 — Definitions of 'Mark,' 'Label' and 'Manufacturer's Designation'A 'facility' is all or any portion of buildings, structures, site improvements, elements and pedestrian or vehicular routes located on a site, whereas a 'lot' is a portion or parcel of land considered as a unit, a 'structure' is that which is built or constructed, and a 'building' is any structure used or intended for supporting or sheltering any use or occupancy.
IBC 2015 Chapter 2 — Definitions of 'Facility,' 'Lot,' 'Structure' and 'Building'An incinerator room requires both a 2-hour separation AND an automatic sprinkler system, while furnace rooms and refrigerant machinery rooms require 1 hour OR sprinklers.
IBC 2015 Chapter 5 — Table 509 Incidental UsesOccupant load for fixed seating without dividing arms is not less than one person per 18 inches of seating length; for booths it is one person per 24 inches of booth seat length measured at the backrest.
IBC 2015 Chapter 10 — Section 1004.4 Fixed SeatingPrescriptive rafter tables with a ceiling attached use a deflection limit of L/Δ = 240, tables with ceiling not attached use L/Δ = 180, and floor joist span tables (30 psf sleeping and 40 psf living live loads) use L/Δ = 360.
IBC 2015 Chapter 23 — Section 2308.7.2 and Tables 2308.7.2(1) through 2308.7.2(6)Joists or structural floors closer than 18 inches to exposed ground must be naturally durable or preservative-treated, while girders trigger that requirement only when closer than 12 inches to exposed ground.
IBC 2015 Section 2304.12.1.1 (Chapter 23)Combustible framing must be not less than 2 inches from flues, chimneys and fireplaces, but 6 inches away from flue openings specifically.
IBC 2015 Section 2304.5 (Chapter 23)0.3 inch per occupant is the general stairway capacity factor, and the reduced 0.2-inch factor applies only to buildings (other than Groups H and I-2) equipped throughout with both an automatic sprinkler system and an emergency voice/alarm communication system.
IBC 2015 Chapter 10 — Section 1005.3.1 StairwaysDead ends are limited to 20 feet where more than one exit or exit access doorway is required, but up to 50 feet is permitted in Groups B, E, F, I-1, M, R-1, R-2, R-4, S and U where the building is sprinklered throughout per Section 903.3.1.1.
IBC 2015 Chapter 10 — Section 1020.4 Corridors, Dead EndsHandrail height above stair tread nosings or ramp finish surface must be uniform at not less than 34 and not more than 38 inches; the 30-to-34-inch range applies only to alternating tread devices and ships ladders.
IBC 2015 Chapter 10 — Section 1014.2 Handrails, HeightType I noncircular handrails have a perimeter of not less than 4 inches and not greater than 6-1/4 inches, while a perimeter greater than 6-1/4 inches makes it Type II and requires a graspable finger recess on both sides of the profile.
IBC 2015 Chapter 10 — Section 1014.3.2 Handrail Graspability, Type IIType V sulfate-resistant cement should be used where concrete is exposed to severe sulfate soils or solutions, and Type II in moderate sulfate exposures (Type III is high-early-strength, not sulfate-resisting).
Concrete Manual (2015 IBC / ACI 318-14), Chapter 4 — Section 4.2 (Deficiencies of the Concrete Itself)Where a general requirement conflicts with a specific requirement for the same condition, the specific requirement governs; the 'most restrictive governs' rule applies instead where different sections specify different materials, methods of construction or other requirements for the same case.
IBC 2015 Chapter 1 — Section 102.1 GeneralBefore use, fire-retardant-treated wood must be dried to 19% or less moisture content for lumber and 15% or less for wood structural panels.
IBC 2015 Section 2303.2Key Terms
Formulas to Know
Width = occupant load × 0.3 inch per occupant; worked example: 300 occupants × 0.3 = 90 inches (Group B, nonsprinklered). Use 0.2 inch per occupant only for buildings other than Groups H and I-2 equipped throughout with an automatic sprinkler system AND an emergency voice/alarm communication system. The 44-inch minimum stairway width of §1011.2 does not override a larger required capacity.(actual number of dwelling units ÷ 4) + (ratio for the other occupancy) shall not exceed one.One 30-inch by 48-inch wheelchair space per 200 occupants or portion thereof, based on the occupant load of the area of refuge and the areas it serves.Fixed seating without dividing arms: not less than one person per 18 inches of seating length. Seating booths: one person per 24 inches of booth seat length measured at the backrest.W/C (by weight) × 94 lb per bag ÷ 8.33 lb per gallon = gallons per bag; worked example: 0.44 × 94 = 41.4 lb ÷ 8.33 ≈ 5.0 gal per bag.Taking the standard 6-by-12-inch cylinder (L/D = 2.0) as 100 percent, a 6-inch-diameter specimen 9 inches long indicates about 104 percent of that strength; correction factors for L/D less than 2.0 are applied for direct comparison (ASTM C39 and C42).Resistance = cohesion × contact area, but in no case shall it exceed one-half the dead load.Force = not less than 16 psf × area of the structure projected on a plane normal to the assumed wind direction; design net wind pressure for components and cladding shall be not less than 16 psf acting in either direction normal to the surface.f2 = 0.7 for roof configurations (such as saw tooth) that do not shed snow off the structure and 0.2 for other roof configurations; f1 = 0.5 for ordinary live loads and 1 for public assembly live loads over 100 psf and parking garages.Combustible exterior wall coverings shall not exceed 10 percent of the exterior wall surface area where the fire separation distance is 5 feet or less; worked example: a 4-foot fire separation distance on a Type II building falls under the 10 percent limit.