Kansas Framing Contractor Exam (ICC KGJ, 2018 IBC/IRC)

Kansas  ·  Pearson Vue

Verified, not estimated. Every figure below is drawn from the official exam structure we maintain — question counts, passing standard and topic weighting. Practice questions are grounded in the source law with statute citations. We omit any figure we can't verify rather than guess at it.
Total questions
50
Passing score
75%
Exam time
150 min
Administered by
Pearson Vue
Format
Reference materials allowed

Kansas State Portion 50 questions

General Trade Knowledge 13 Q · 26%
Scope and applicability of IRC vs. IBC (dwelling types, story limits, accessory structures)Key code definitions for structural and framing terms (dead load, live load, braced wall line, diaphragm, light-frame construction)Building official authority, duties, and permit administrationClimatic and geographic design criteria (wind speed, seismic design category, snow load, flood hazard area)Minimum live and dead load requirements for floors, roofs, and structural membersStructural design methods and load combinations (ASD, LRFD, strength design)Risk category classification and its effect on design requirementsAlternative materials, engineered design, and referenced standards applicabilityScope and AdministrationDefinitionsBuilding PlanningStructural Design
Foundation and Floor Framing 11 Q · 22%
Footing size, depth, and frost protection requirements (IRC/IBC)Foundation wall types and prescriptive design (concrete and masonry)Foundation anchorage and sill plate attachmentFloor joist span tables, species, grades, and spacingGirder and header spans for floor framingFloor sheathing (lumber and wood structural panel) allowable spans and installationJoist notching, boring, and hole limitationsSoil classification and presumptive load-bearing valuesWoodFoundationsSoils and FoundationsFloors
Wall Framing 16 Q · 32%
Stud size, height, and spacing requirements for bearing and nonbearing wallsHeader and girder spans for exterior and interior bearing wallsTop plate and bottom plate requirements, including double top plate splicingDrilling and notching limitations for studs and top platesWall bracing methods, braced wall panel construction, and required bracing lengthsFastening schedules for wall framing connectionsCripple wall framing and bracing requirementsCold-formed steel wall framing member sizes, fastening, and web hole limitationsWall ConstructionWood
Roof Framing 10 Q · 20%
Rafter span tables and slope requirements (IBC/IRC conventional light-frame)Ceiling joist span tables and attic live load conditionsRoof framing member connections and nailing requirements (ridge, hip, valley, collar tie, rafter ties)Wood truss design requirements, truss design drawings, and truss member restraint/bracingRoof sheathing materials, allowable spans, and installation (lumber and wood structural panels)Roof load types and combinations (dead, live, snow, wind, rain/ponding) per IBC Chapter 16Rafter and truss uplift connection forces and wind tie-down requirementsMinimum slope requirements and framing details for ridge board, hip, valley, and purlin bracingWoodStructural DesignRoof-Ceiling Construction

Key Distinctions

Townhouse common wall WITH automatic residential sprinklers (P2904)vsTownhouse common wall WITHOUT sprinklers

IRC R302.2.2 Item 1 allows a 1-hour fire-resistance-rated assembly where a P2904 sprinkler system is provided, while Item 2 requires not less than a 2-hour rated assembly where it is not.

IRC 2018 Page 59
CarportvsGarage

Per IRC R309.2 a carport must be open on not less than two sides; a vehicle shelter not open on two or more sides is considered a garage and must meet the garage provisions including the R302.6 separation.

IRC 2018 Section R309.2
Prescriptive story height — wood wall framingvsPrescriptive story height — masonry walls

IRC R301.3 Item 1 limits wood wall framing story height to 11 feet 7 inches and, separately, to the laterally unsupported bearing wall stud height permitted by Table R602.3(5) (the two are not added); Item 3's 13 feet 7 inches applies to masonry walls (with bearing wall clear height not more than 12 feet). Where these limits are exceeded, the wind and seismic design must follow the IBC.

IRC 2018 Section R301.3
Crawl space access opening through a perimeter wallvsCrawl space access opening through the floor

IRC R408.4 requires through-wall access openings to be not less than 16 inches by 24 inches, while access through the floor shall be not smaller than 18 inches by 24 inches (a below-grade through-wall access also needs an areaway at least 16 by 24 inches).

IRC 2018 Section R408.4
Braced wall line 16 feet or less — two panelsvsBraced wall line 16 feet or less — single panel

IRC R602.10.2.3 allows braced wall lines 16 feet or less to have not less than two braced wall panels of any length, or alternatively one braced wall panel equal to 48 inches or more.

IRC 2018 Section R602.10.2.3
1,800-pound hold-down (SDC D0–D2 panel-offset exception)vs800-pound hold-down (continuously sheathed corner-return condition)

IRC R602.10.2.2.1 Exception Item 2 requires an 1,800-pound hold-down at the panel end nearest the corner when Method WSP/BV-WSP/continuous-sheathing panels begin not more than 10 feet from each end of a braced wall line in SDC D0–D2; the 800-pound device belongs to the corner-return/hold-down condition for continuously sheathed wall line ends.

IRC 2018 Section R602.10.2.2.1
Collector (drag strut)vsDiaphragm chord

IBC Section 202 defines a collector as the horizontal diaphragm element parallel and in line with the applied force that transfers diaphragm shear to the vertical lateral force-resisting elements, while a diaphragm chord is the boundary element perpendicular to the applied load that takes axial stresses from the diaphragm moment.

IBC 2018 Page 18
Guard opening limits on the open side of stairsvsGeneral guard opening and the riser/tread/bottom-rail triangle

IRC R312.1.3 Exception 2 permits guards on the open side of stairs to have openings that will not pass a 4 3/8-inch sphere, whereas the general guard limit is a 4-inch sphere and the triangular opening at the riser, tread and bottom rail is limited to a 6-inch sphere (Exception 1).

IRC 2018 Page 74
Crawl space ventilation with exposed ground (no vapor retarder)vsCrawl space ventilation with ground covered by Class I vapor retarder

IRC R408.1 requires not less than 1 square foot of net ventilation area per 150 square feet of under-floor area where the ground is uncovered; the 1-per-1,500 ratio applies only where a Class I vapor retarder covers the ground.

IRC 2018 Section R408.1
Smoke alarm clearance from a permanently installed cooking appliance — ionization typesvsSmoke alarm clearance from a permanently installed cooking appliance — photoelectric

IRC R314.3.1 requires plain ionization alarms to be not less than 20 feet horizontally and ionization alarms with an alarm-silencing switch not less than 10 feet horizontally from the appliance, while photoelectric alarms require 6 feet; the 3-foot dimension in R314.3 Item 4 applies to bathroom door openings instead.

IRC 2018 Section R314.3.1
IRC permit extension (issued permit)vsIBC permit application extension (permit not yet issued)

IRC R105.5 makes a permit invalid if work is not commenced within 180 days or more than 180 days pass between inspections, with written extensions of not more than 180 days each; IBC 105.3.2 deems an application abandoned 180 days after filing, with written extensions not exceeding 90 days each.

IRC 2018 Section R105.5
Load-bearing wood or metal stud wallvsLoad-bearing masonry or concrete wall

IBC Section 202 'WALL, LOAD-BEARING' classifies a metal or wood stud wall as load bearing when it supports more than 100 pounds per linear foot of vertical load in addition to its own weight, while the 200-pounds-per-linear-foot threshold applies to masonry or concrete walls.

IBC 2018 Page 42

Key Terms

Cripple wall IRC 2018 Section R202 — Cripple wall
A framed stud wall extending from the top of the foundation to the underside of the floor framing of the first story above grade plane (IBC: of the lowest occupied floor level).
Story above grade plane IRC 2018 Section R202 — Story above grade plane
Any story in which the finished surface of the floor next above is more than 6 feet above grade plane, or more than 12 feet above the finished ground level at any point.
Grade plane IRC 2018 Section R202 — Grade plane
The reference plane established by the lowest points of finished ground level between the building and the lot line, or, where the lot line is more than 6 feet from the building, between the structure and a point 6 feet from the building where the ground slopes away from the exterior walls.
Grade floor opening IBC 2018 Page 27
A window or other opening located such that the sill height is not more than 44 inches above or below the finished ground level adjacent to the opening (IBC Section 202).
Collector (drag strut) IBC 2018 Page 18
A horizontal diaphragm element parallel and in line with the applied force that collects and transfers diaphragm shear forces to the vertical elements of the lateral force-resisting system.
Diaphragm chord IBC 2018 Section 202 — Diaphragm
A diaphragm boundary element oriented perpendicular to the applied load that is assumed to take axial stresses due to the diaphragm moment.
Rigid diaphragm IBC 2018 Section 1604.4
For distribution of story shear and torsional moment, a diaphragm whose lateral deformation is not more than (less than or equal to) two times the average story drift (IBC 1604.4).
Foundation pier (Chapter 21) IBC 2018 Section 202 — Foundation pier
An isolated vertical foundation member whose horizontal dimension measured at right angles to its thickness does not exceed three times its thickness and whose height is equal to or less than four times its thickness.
Steep slope IBC 2018 Section 202 — Steep slope
A roof slope greater than two units vertical in 12 units horizontal (17-percent slope) per IBC Section 202.
Susceptible bay IBC 2018 Section 202 — Susceptible bay
A roof or portion thereof with a slope less than 1/4 inch per foot, or on which water is impounded when the primary drainage is blocked.
Windborne debris region IBC 2018 Section 202 — Windborne debris region
Areas within hurricane-prone regions within 1 mile of the coastal mean high-water line where the basic design wind speed V is 130 mph or greater, or areas where the basic design wind speed is 140 mph or greater regardless of distance from the coast.
Cross-laminated timber IBC 2018 Page 19
A prefabricated engineered wood product of not less than three layers of solid-sawn lumber or structural composite lumber with adjacent layers cross oriented and bonded with structural adhesive to form a solid wood element.
Parallel strand lumber (PSL) IBC 2018 Pages 39 to 40
Structural composite lumber made of wood strand elements with fibers oriented along the member length, the least dimension of the strands being 0.25 inch or less and average lengths not less than 300 times the least dimension.
H (design load notation) IBC 2018 Section 1602.1
The load due to lateral earth pressures, ground water pressure or pressure of bulk materials (IBC 1602.1); F is fluid load, T is self-straining loads, R is rain load.
Uninhabitable attic with storage IBC 2018 Table 1607.1, Footnotes i and j
Per Table 1607.1 footnote j, an attic where the maximum clear height between joists and rafters is 42 inches or greater, or where two or more adjacent trusses have webs that can accommodate an assumed rectangle of at least 42 inches high by 24 inches wide within the plane of the trusses.
Sunroom Category V IRC 2018 Section R301.2.1.1.1
Per IRC R301.2.1.1.1, a sunroom with enclosed walls that is heated or cooled and open to the main structure — habitable and conditioned space.

Formulas to Know

Natural light and ventilation for habitable rooms (IRC R303.1)Aggregate glazing area ≥ 8% of floor area; openable area to outdoors ≥ 4% of floor area ventilated. Example: 300 sq ft room → 300 × 0.08 = 24 sq ft glazing and 300 × 0.04 = 12 sq ft openable.
Minimum number of stair risers (IRC R311.7.5.1, max riser 7 3/4 in.)Risers = total rise ÷ 7.75, rounded up to the next whole number. Example: 112 in. ÷ 7.75 = 14.45 → 15 risers (≈7 7/16 in. each); 14 risers would give 8 in. and would not comply.
Under-floor (crawl space) ventilation net area (IRC R408.1)Exposed ground, no Class I vapor retarder: 1 sq ft net area per 150 sq ft of under-floor area. Example: 1,800 ÷ 150 = 12 sq ft. Where a Class I vapor retarder covers the ground, the 1-per-1,500 ratio applies (1,800 ÷ 1,500 = 1.2 sq ft).
Masonry-unit footing dimensions (IBC 1809.9.1, prescriptive)Width ≥ wall thickness + 8 in.; depth ≥ 2 × projection beyond the wall. Example: 12-in. wall → 12 + 8 = 20 in. wide; projection = 4 in. each side → depth = 2 × 4 = 8 in. Mortar must be Type M or S.
Roof live load area reduction factor R1 (IBC 1607.13.2.1)R1 = 1 for At ≤ 200 sq ft; R1 = 1.2 − 0.001At for 200 < At < 600 sq ft; R1 = 0.6 for At ≥ 600 sq ft.
Roof live load slope factor R2 and the factor F (IBC 1607.13.2.1)For a sloped roof, F = number of inches of rise per foot; R2 = 1.2 − 0.05F. (For an arch or dome, F is the rise-to-span ratio multiplied by 32; the percentage slope form is used only in the SI conversion.)
Reduced roof live load Lr (IBC 1607.13.2.1) — worked exampleLr = Lo × R1 × R2, but not less than 12 psf. Example: At = 500 sq ft, F = 8 in./ft, Lo = 20 psf → R1 = 1.2 − 0.001(500) = 0.70; R2 = 1.2 − 0.05(8) = 0.80; Lr = 20(0.70)(0.80) = 11.2 psf → use 12 psf.
Foundation cripple wall bracing length (IRC R602.10.10)Use the same bracing method and table length as the wall above, then multiply the required bracing length by 1.15; adjustments for omitting interior gypsum board are taken in addition to this increase.
Cripple walls at interior braced wall lines without continuous foundation (IRC R602.10.10.1)Brace adjacent parallel cripple walls with Method WSP or CS-WSP and multiply the Table R602.10.3(3) bracing length by 1.5; where length is still insufficient, reduce panel edge fastener spacing to 4 in. o.c. and adjust the required bracing length by 0.70; if still insufficient, design per accepted engineering practice.
Application of roof live loads on sloping surfaces (IBC 1607.13)Live loads on a sloping surface are assumed to act vertically on the horizontal projection of that surface, so rafter spans and roof live loads are evaluated on the horizontal run rather than the sloped length.