Verified, not estimated. Every figure below is drawn from the official exam structure we maintain — question counts, passing standard and topic weighting. Practice questions are grounded in the source law with statute citations. We omit any figure we can't verify rather than guess at it.
Total questions
40
Passing score
73%
Exam time
120 min
Administered by
Prov
Format
Reference materials allowed
Tennessee State Portion
40 questions
General Knowledge3 Q · 8%
IPC definitions and plumbing code terminologyIPC scope, permit requirements, and inspection proceduresTypes, properties, and applications of plastic pipe (ABS, PVC, CPVC, PEX, PE, PB)Plastic pipe sizing, labeling, schedules, and SDR ratingsReading and interpreting construction drawings (floor plans, riser diagrams, isometric sketches, plumbing symbols)Model plumbing codes (the IPC): structure, purpose, and chapter organizationCode development, revision, and adoption process for model and local codesCompressed-air system components, installation, and safety
Plumbing Math2 Q · 5%
Arithmetic operations and formula solving for plumbing applicationsUnit conversions and measurement systems (English and metric)Geometric shapes, area, and volume calculationsPythagorean theorem and right triangle solutionsPipe offset, diagonal, rise, and run calculations using angle constantsWater pressure, head, and force calculationsPipe capacity, weight of water, and volume-to-gallon conversions for cylindrical and rectangular containersRatio of pipe capacities and pipe sizing using units of flowTemperature conversion between Fahrenheit and CelsiusDecimal, fraction, and percentage conversions including inches-to-decimal-foot equivalents3-4-5 ratio and square corner layout using the Pythagorean theorem
Code Requirements4 Q · 10%
AdministrativeStructuralBackflowMaterials and SupportsJoints and ConnectionsTestingPermits and permit exemptionsInspections (underground, rough-in, and final)Violations, stop work orders, and enforcement authorityMeans of appeals and board of appealsReferenced standards and their applicationFlood hazard area requirements+1 more
Water Supply and Distribution4 Q · 10%
Potable water protection and cross-connection controlBackflow prevention devices and assembliesPipe materials, fittings, and joining methods for water service and distributionWater pressure requirements, pressure-reducing valves, and booster systemsHot water supply system requirements and thermal expansion controlWater piping system sizing using fixture units and segmented loss methodWater heater installation, safety devices, and relief valve discharge pipingWater volume, pressure, and capacity calculations
Water Heaters2 Q · 5%
Water HeatersSafety devices for water heaters including relief valves and discharge pipingWater heater installation requirements including access, location, and connectionsHot water supply system requirements including temperature limits and recirculationTypes of water heaters including gas, electric, tankless, heat pump, and indirectWater heater selection criteria including capacity, fuel type, recovery rate, and durabilityThermal expansion protection including expansion tanks and closed systemsGas water heater venting requirements and flue installationWater heater safety hazards including electrical, gas, and steam risksAntisiphon devices, vacuum relief valves, and drain valvesParallel and series water heater connections for multi-unit installationsFlammable vapor ignition resistant (FVIR) water heater requirements
Drain, Waste, and Vent Systems10 Q · 25%
Indirect WasteSpecial WasteDrainage fixture unit (DFU) values and system sizingHorizontal drainage pipe slope and installation requirementsCleanout placement, sizing, and access requirementsTrap requirements, prohibited trap types, and trap seal protectionVent types, sizing, and terminal requirementsGrease interceptors and other interceptors and separatorsSumps, ejectors, and below-grade drainage systemsPipe materials, fittings, and joint methods for drainage and vent systems
Fixtures & Fittings2 Q · 5%
Minimum number of required plumbing fixtures by occupancy classificationFixture installation requirements and clearancesFaucets and fixture fittings including shower valves and temperature limiting devicesBackflow protection for plumbing fixtures and appliancesFixture-specific standards and waste outlet requirementsFixture materials and construction standards (vitreous china, porcelain enamel, cast iron, stainless steel, fiberglass/GRP, acrylic plastic)Water closet types, flushing mechanisms, and water conservation requirementsUrinal types, flushing devices, and substitution limits for water closetsADA and accessibility requirements for fixture installation and clearancesShower compartment construction, lining materials, and waste outlet requirementsAppliance connections (dishwashers, food waste disposers, washing machines, refrigerator ice makers)Whirlpool bathtub installation requirements including pump access and suction fittings+1 more
Isometrics7 Q · 18%
Center-to-center and end-to-end pipe length calculationsFitting allowances for threaded, copper, PVC, and welded fittings45-degree offset calculations using diagonal and rise/run constantsOffset calculations for other fitting angles (60°, 22½°, 11¼°, 72°) using trigonometric constantsThree-pipe diagonal assembly layout and pipe length determinationRolling offsets and true offset calculationsParallel offset spacing and equal spacing calculationsReading and applying pipe fitting data tables from appendix references
Fuel Gas Systems4 Q · 10%
Gas AppliancesGas PipingGas piping materials and fittings (metallic pipe, copper tubing, CSST, polyethylene plastic)Pipe sizing methods (longest length, branch length, hybrid pressure)Pressure testing and leak checks of gas piping systemsCombustion air requirements for gas appliances (indoor, outdoor, and combination methods)Venting systems for gas appliances (vent types, connectors, termination, sizing)Appliance location, clearances, and installation requirementsSpecific gas appliance requirements (furnaces, unit heaters, unvented room heaters, clothes dryers, water heaters)
OSHA Safety2 Q · 5%
Employer accident prevention responsibilities and safety programsPersonal protective equipment (PPE) selection, provision, and paymentFall protection systems — guardrails, safety nets, and personal fall arrestExcavation safety — cave-in protection, sloping, shoring, and competent person inspectionsConfined space entry procedures and permit-required confined spacesFire protection and prevention — extinguishers, flammable liquid storage, and fire prevention plansHazardous substances exposure limits and asbestos handling requirementsWelding and cutting — compressed gas cylinder handling and storage
Full-open valves are required at locations such as near the curb, at the meter discharge, at the building entrance and at each water heater, while shutoff valves are what is required on the supply to each sillcock, each appliance and each fixture supply (a lavatory fixture supply in a one-family dwelling needs a shutoff valve, not a full-open valve).
Equal spacing makes the center-to-center lengths equal, but because each fitting type has its own fitting allowance, assemblies using different fittings (90° ell vs 45° ell) have different end-to-end cut lengths.
Mathematics for Plumbers and Pipefitters (8th ed.), Chapter 1 — Equal Spacing
Water service pipe installed underground and outside the structurevsHot water distribution pipe and tubing
Water service pipe/tubing must have a working pressure rating of not less than 160 psi at 73.4°F (IPC 605.3), while hot water distribution pipe must be rated not less than 100 psi at 180°F (IPC 605.4).
An approved ASSE 1003 pressure-reducing valve with strainer is required where static water pressure in the building exceeds 80 psi (reducing distribution pressure to not greater than 80 psi static), whereas a booster pump's low-pressure cutoff must act when a positive pressure of 10 psi or less occurs on the pump suction side.
IPC 2021 Section 604.8
Urinal substitution in assembly and educational occupanciesvsUrinal substitution in all other occupancies
Per IPC 424.2 urinals shall not be substituted for more than 67 percent of required water closets in assembly and educational occupancies, versus a 50-percent limit in all other occupancies.
IPC 2021 Section 424.2 — Urinals, Substitution for water closets
Drainage and vent system water test in sections (IPC 312.2)vsWater supply system air test on non-plastic piping (IPC 312.5)
Each tested section of drainage/vent must hold not less than a 10-foot head of water for not less than 15 minutes, while the water supply system (piping other than plastic) may be tested with air at not less than 50 psi held for not less than 15 minutes.
IPC 2021 Section 312.2
Stack ventvsVent stack
A stack vent is the vent extension of the drainage stack itself (sized from Table 906.1, e.g., 1½ in permitted for a 3 in stack with 21 DFU up to 32 ft developed length), while the vent stack is a separate vertical vent pipe that circulates air through the drainage system, connecting near the base of the soil stack and rejoining the stack vent above the highest fixture.
IPC 2021 Table 906.1
Trench overexcavation for soft soil (IPC 306.2.3)vsBackfill cover over the pipe crown (IPC 306.3)
Where soft, poor load-bearing material is found at the trench bottom, overexcavate not less than two pipe diameters and backfill to grade with fine gravel, crushed stone or concrete; separately, loose earth backfill is placed in 6-inch layers and tamped until the pipe crown is covered by 12 inches of tamped earth before the remaining backfill is placed.
Per IPC 504.6 item 10, the discharge pipe shall terminate not more than 6 inches above the floor or flood level rim of the waste receptor (maximum) and not less than two times the discharge pipe diameter above it (minimum).
One miter cut across the pipe produces a bend of twice the cut angle, so the miter angle is always one-half of the desired fitting angle.
Mathematics for Plumbers and Pipefitters (8th ed.), Chapter 2 — Miter Cuts—Welded Pipe
Cast iron bend fractionsvsDegrees of bend
A ¼ bend is 90°, a ⅕ bend is 72°, a ⅛ bend is 45° and a 1/16 bend is 22½°; these match the angles of threaded fittings so the same offset constants apply.
Mathematics for Plumbers and Pipefitters (8th ed.), Chapter 2 — Cast Iron Assemblies with Various Bends
Lead monitoring result notification (29 CFR 1926.62(d)(8)(i))vsLead exposure record retention (29 CFR 1926.62(n)(1)(iii))
Affected employees must be notified of monitoring results as soon as possible but no later than 5 working days after receipt (in writing or by posting), while the monitoring/exposure assessment records themselves must be kept at least 30 years.
A vertical length of stack of 8 feet or more between the connections of horizontal branches (IPC 2021 Section 202).
Vent stack IPC 2021 Section 202
A separate vertical vent pipe installed to circulate air through the drainage system, connecting near the base of the soil stack and rejoining the stack vent above the highest fixture.
Vent stack connection to the building drain (IPC 904.4) IPC 2021 Section 904.4
Where a vent stack connects to the building drain instead of the drainage stack, the connection must be downstream of the drainage stack and within a distance of 10 times the diameter of the drainage stack.
A vent installed within two pipe diameters of the trap weir is a prohibited crown vent, so a 2-inch trap requires the vent connection at not less than 4 inches (2 × 2) from the trap weir.
An individual vent is sized at not less than half the diameter of the fixture drain it serves but never smaller than 1¼ inches, and any vent exceeding 40 feet of developed length is increased one nominal pipe size for its entire length.
Tempered water (IPC 419.5) IPC 2021 Section 419.5
Water in the 85°F to 110°F range that must be delivered from public hand-washing lavatories through a device conforming to ASSE 1070/ASME A112.1070/CSA B125.70.
Asbestos-containing material (ACM) 29 CFR 1926, §1926.1101(b)
Per 29 CFR 1926.1101(b), any material containing more than one percent asbestos.
Shower compartment (IPC 421.4 and 421.4.1) IPC 2021 Section 421.4
A compartment having not less than 900 square inches of interior cross-sectional area with a minimum least dimension of 30 inches measured from the finished interior dimension, with wall materials extending not less than 6 feet above the room floor level and not less than 70 inches above the drain of the tub or shower.
The shower pan liner must turn up on all sides not less than 2 inches above the finished threshold level and be pitched one-fourth unit vertical in 12 units horizontal toward the drain.
A fitting explicitly listed as a prohibited joint/connection in both water supply systems (IPC 605.9) and sanitary drainage systems (IPC 707.1).
Trough urinal (IPC 401.2) IPC 2021 Section 401.2
A urinal type that is outright prohibited by the code regardless of compliance with any other standard.
Temperature and pressure (T&P) relief valve (IPC 504.5) IPC 2021 Section 504.5
A water heater relief valve having a temperature setting of not more than 210°F and a pressure setting not exceeding the tank manufacturer's rated working pressure or 150 psi, whichever is less.
Water heater pan (IPC 504.7 and 504.7.1) IPC 2021 Sections 504.7 and 504.7.1
Where required, the pan shall be not less than 1½ inches deep and drained by an indirect waste pipe having a diameter of not less than ¾ inch.
Condensate drain line (IPC 314.2.1 and 314.2.2) IPC 2021 Section 314.2.2
Waste/drain piping of not less than ¾-inch pipe size that shall not decrease in size from the drain pan connection to the point of disposal, sloped in the direction of discharge not less than one-eighth unit vertical in 12 units horizontal (1-percent slope).
Water service pipe (IPC 603.1) IPC 2021 Section 603.1
The building water service shall be not less than ¾ inch in diameter regardless of the fixture unit demand calculation.
Vitreous china Plumbing Basics (4th ed.), Chapter 8 — Vitreous China section
Fixture material for water closets, urinals and bidets made primarily from a fine clay called kaolin, which may also include quartz, feldspar, silica and other materials.
Formulas to Know
End-to-end cut length of pipe between fittingse-e = c-c − total fitting allowances (one allowance per pipe end); example: 10 in − (½ in for the 90° ell + ¼ in for the 45° ell) = 9¼ in; six ends example: 2 × 13/16 in (90° ells) + 4 × 7/16 in (45° ells) = 3-3/8 in total allowance
45° offset constantsdiagonal = 1.414 × offset; offset = 0.707 × diagonal (e.g., 0.707 × 14 in = 9.90 in; 0.707 × 20 in = 14-1/8 in); run = 1.000 × offset (e.g., 1.000 × 8 in = 8 in)
30°, 60° and 22½° offset constants30° offset: diagonal = 2.000 × offset; 60° offset: diagonal = 1.155 × offset (1.155 × 30 in = 34-5/8 in) and run = 0.577 (0.5774) × offset (0.5774 × 24 in ≈ 13.9 in; 0.577 × 18 in = 10-3/8 in); 22½° offset: diagonal = 2.613 × offset
Fall of horizontal drain piping at ¼ inch per footFall (in) = length (ft) × 0.25; e.g., 188 ft × 0.25 = 47 in; 6.5 ft trap arm × 0.25 = 1.625 in (1-5/8 in), which must not exceed the trap arm diameter so the vent stays above the trap weir
Equivalent length of water piping where the figure prints a 50-percent fitting allowanceEquivalent length = developed length × 1.5 when the problem prints a 50% allowance for fittings; e.g., (30 + 16 + 30 + 22) = 98 ft developed × 1.5 = 147 ft
Pressure available for friction loss to an outletAvailable pressure = static pressure at main − meter loss − (elevation in ft × 0.433) − required flow pressure at the outlet; e.g., 55 − 5 − (27 × 0.433 = 11.7) − 20 = 18.3 psi; the outlet left with the least pressure governs the design
Allowable friction loss per 100 feet of pipepsi per 100 ft = available pressure ÷ equivalent length × 100; e.g., 39.6 psi ÷ 160.5 ft × 100 = 24.7 psi per 100 ft, the value taken to the friction-loss chart
Drainage fixture units from a known gpm discharge1 gpm = 2 DFU (IPC 709.3); e.g., 8 gpm × 2 = 16 DFU
Listed corrugated metallic chimney liner capacity in a masonry chimneySize from Type B vent Table 504.2(1) or 504.2(2) with maximum capacity × 0.80 (reduce 20 percent), which includes an allowance for one long-radius 90-degree turn at the bottom of the liner