Verificado, no estimado. Cada cifra a continuación proviene de la estructura oficial del examen que mantenemos: número de preguntas, puntaje de aprobación y ponderación de temas. Las preguntas de práctica están fundamentadas en la ley fuente con citas de estatutos. Omitimos cualquier cifra que no podamos verificar en lugar de adivinarla.
Total de preguntas
110
Puntaje de aprobación
75%
Tiempo del examen
300 min
Administrado por
PROV
Formato
Se permiten materiales de referencia
Porción Estatal de Alabama
110 preguntas
Organización Empresarial1 Q · 1%
Business legal structures (sole proprietorship, partnership, corporation, LLC) — characteristics, advantages, and disadvantagesLiability exposure by business structure typeTaxation differences among business entity typesFormation documents required for each business structure (DBA filing, partnership agreement, articles of incorporation, operating agreement)Joint ventures — formation, management, and licensing considerationsBusiness naming, fictitious names/DBA registration, and trademark basicsBusiness plan elements and purpose (planning, loan/investor, benchmarking tool)New business startup checklist — organizational steps and professional advisors
Gestión de Riesgos2 Q · 2%
Risk assessment fundamentals and probability of lossTypes of property insurance for contractors (builder's risk, inland marine, equipment floater)Commercial general liability (CGL) insurance coverage and exclusionsSurety bonds: types, qualifying requirements, and bond languageEmployment-related insurance (workers' compensation, unemployment, Social Security)Insurance coverage requirements for subcontractorsMiller Act and Little Miller Acts bonding requirements for federal projectsCoverage gaps, overlaps, and business owner's policies (BOPs)
Gestión de Proyectos2 Q · 2%
Scheduling methods: calendar, bar chart, and critical path method (CPM)Scheduling process elements: sequence of tasks, activity duration, contingency time, and float timeScheduling and cash flow managementProject manager and supervisory team roles (superintendent, foreman, materials expediter)Budget tracking and cost overrun controlsMaterials management: just-in-time delivery, purchase orders, and receivingCustomer communication, change order handling, and negotiation basicsSubcontractor selection, site rules, and employee vs. independent contractor classification
Estimación de Costos4 Q · 4%
Bid documents and bid package componentsEthics in bidding (bid shopping, bid peddling, bid rigging)Estimate planning and site visit considerationsEstimating framework and quantity take-off methodDetermining direct costs (labor, materials, equipment)Labor burden and overhead calculationsMarkup, profit margin, and cost-based pricingJob cost recording system and estimating technology tools
Seguridad y Medio Ambiente2 Q · 2%
OSHA standards and recordkeeping requirements (Forms 300, 300A, 301)OSHA penalty types and violation classificationsEmergency action plan requirementsSafety Data Sheets (SDS) and Hazard Communication StandardUnderground utility and overhead power line safetyEnvironmental laws and EPA regulatory frameworkAsbestos and lead-based paint regulations and renovation requirementsHazardous and non-hazardous solid waste identification and disposal
Leyes Laborales3 Q · 3%
Alabama Workers' Compensation coverage requirements and employer exemptionsSecuring workers' compensation payment: insurance vs. self-insurance optionsEmployer reporting obligations for injuries and compensation settlementsDrug-free workplace program requirements and workers' compensation premium discountsFair Labor Standards Act: minimum wage, overtime, and recordkeeping requirementsHiring minors: working hour restrictions and prohibited hazardous tasks in constructionEmployment eligibility verification: Form I-9 requirements and documentationAnti-discrimination laws: ADA, Title VII, ADEA, and Equal Pay Act applicability
Nómina e Impuestos de Empleo4 Q · 4%
Federal Employer Identification Number (EIN) requirements and applicationSocial Security and Medicare taxes (FICA) — calculation and employer/employee withholdingFederal income tax withholding — W-4 and W-2 formsFederal Unemployment Tax (FUTA) — rates, thresholds, deposit schedules, and Form 940Alabama Unemployment Compensation (UC) employer liability and registration — Form SR-2Alabama UC taxable wage base, contribution rates, and experience ratingAlabama quarterly contribution and wage report filing — Form UC-CR4, deadlines, penalties, and interestAlabama new-hire reporting requirements and procedures
Gestión Financiera4 Q · 4%
Bookkeeping practices and the accounting cycleFinancial statements (balance sheet, income statement, statement of cash flows)Financial ratio analysis (liquidity, quick, activity, debt, profitability, return on assets)Cash and accrual methods of accountingContract accounting methods (completed contract, percentage of completion, cost comparison)Cash flow management, accounts receivable collection, and progress paymentsEquipment depreciation methods (straight-line and accelerated/MACRS)Payroll accounting (gross pay, deductions, net pay, payroll journal)
Contratos3 Q · 3%
Required elements of a binding contract (offer, acceptance, consideration, competent parties, legal purpose)Types of construction contracts (lump-sum, unit-price, cost-plus, turnkey, fast-track)Contracting methods (single prime, multiple prime, design/build, construction management, partnering)Contract provisions (payment terms, progress payments, retainage, final payment, obligations of parties)Breach of contract (material vs. immaterial breach, liquidated damages, statute of limitations)Change orders and contract modificationsAlternative dispute resolution (negotiation, mediation, collaborative law, arbitration)Subcontractor agreements and employee vs. independent contractor classification
Leyes de Gravámenes1 Q · 1%
Who qualifies for a mechanic's or materialman's lien (eligible claimants and covered work)Filing requirements for verified lien statement (contents, form, and probate court recordation)Deadlines for filing lien statements by claimant type (original contractor, day laborer, other persons)Priority of mechanic and materialman liens relative to prior mortgages and subsequent encumbrancesNotice requirements for subcontractors and materialmen before filing a lien statementTime limitations for enforcement actions and consequences of failure to actTransfer of lien from real property to alternate security (bond or money deposit)Lien satisfaction, acknowledgment of release, and penalties for failure to release
Leyes de Licencias4 Q · 4%
Alabama Board of Electrical Contractors composition, appointment, and termsQualifications and experience requirements for electrical contractor licensureQualifications and experience requirements for journeyman electrician licensureLicense application, examination administration, and passing standardsLicense fees, renewal, late renewal, and reinstatement proceduresInactive status certification requirements and reinstatement to active licenseLicense exemptions from state electrical licensing requirementsContinuing education requirements, approved providers, and contact hour computation
Conocimientos Generales de Electricidad10 Q · 9%
Ohm's Law and basic DC circuit calculations (voltage, current, resistance, power)Series, parallel, and combination circuit types and current/voltage distributionAC fundamentals: sine waves, frequency, electrical degrees, and phase relationshipsElectrical units and definitions (ampere, volt, ohm, watt, impedance, capacitance, inductance)NEC definitions and terminology for wiring systems (branch circuit, feeder, service, bonding, grounding)General installation requirements of NEC Article 110 (approval, listing, examination, terminations, deteriorating agents)Voltage drop and single-phase / three-phase power calculations
Puesta a Tierra y Unión9 Q · 8%
Grounding electrode system types and selection (NEC 250.52)Grounding electrode conductor sizing using Table 250.66Equipment grounding conductor types, sizing, and identification (NEC 250.118–250.122)Main bonding jumper and system bonding jumper requirementsBonding of services, piping systems, and structural metal (NEC 250.92–250.104)Grounding of separately derived systems and generatorsEffective ground-fault current path requirements for grounded and ungrounded systemsGrounding electrode installation methods and connection requirements (NEC 250.53–250.70)
Conductores y Cables10 Q · 9%
Conductor insulation types, temperature ratings, and type designations (e.g., THHN, XHHW, RHW, TW)Ampacity tables and correction/adjustment factors for conductors rated 0–2000 voltsConductor material, size, and stranding requirements (copper, aluminum, copper-clad aluminum; AWG and kcmil)Grounded conductor identification methods and color codingUses permitted and uses not permitted for specific cable types (NM, NMC, MC, AC, MI, SE, USE, UF, TC, ITC, FC, FCC, IGS, Type P)Securing, supporting, and bending radius requirements for cable assembliesFlexible cords and fixture wires — types, ampacities, permitted uses, and marking requirementsConductor marking requirements and conductor properties (Chapter 9 Table 8)
Canalizaciones y Cajas8 Q · 7%
Conduit fill calculations and conductor count limits (NEC Chapter 9 Tables)Raceway and conduit selection by wiring method type (RMC, IMC, EMT, FMC, LFMC, PVC, ENT, RTRC, LFNC)Securing and supporting requirements for conduits, tubing, and racewaysBox fill calculations and volume allowances (Article 314)Pull box and junction box sizing for conductors 4 AWG and largerUnderground installation requirements and minimum cover depths for racewaysWireway and auxiliary gutter conductor fill, splices, and ampacity rulesCable tray installation, fill requirements, and permitted wiring methods
Ocupaciones Especiales y Equipos4 Q · 4%
Hazardous location classification (Classes I, II, and III; Divisions 1 and 2)Wiring methods and sealing requirements for hazardous locationsHealth care facility essential electrical systems (Type 1 and Type 2 EES)Patient care space grounding, bonding, and receptacle requirementsSwimming pools, spas, and fountains — GFCI protection, bonding, and underwater luminairesSolar PV systems — circuit sizing, overcurrent protection, rapid shutdown, and arc-fault protectionElectric vehicle power transfer system (EVSE) installation and overcurrent protectionFire pump power sources, disconnecting means, and continuity of power requirements
Potencia Eléctrica3 Q · 3%
Transformer installation requirements and NEC Article 450 complianceTransformer overcurrent protection (primary and secondary, 1000 V and below)Transformer types, cooling methods, and insulation classesEmergency system power sources and automatic transfer equipment (NEC Article 700)Generator installation, marking, overcurrent protection, and disconnecting means (NEC Article 445)Legally required standby systems and critical operations power systems (NEC Articles 701 and 708)Energy storage systems and stationary standby batteries (NEC Articles 706 and 480)Interconnected electric power production sources and parallel operation requirements (NEC Article 705)
Motores6 Q · 5%
Motor branch-circuit conductor sizing and ampacity requirementsMotor overload protection selection and settingsBranch-circuit short-circuit and ground-fault protective device ratingsMotor controller types, ratings, and enclosure classificationsDisconnecting means requirements for motors and controllersAC motor types and operating characteristics (squirrel-cage, wound-rotor, synchronous)DC motor types, speed control methods, and starting requirementsHermetic refrigerant motor-compressor circuit requirements
Baja Tensión2 Q · 2%
Class 1, Class 2, and Class 3 circuit classifications and power source limitationsSeparation requirements between low-voltage and power/light circuitsCable types and substitution hierarchy for power-limited circuits (CL2, CL3, CMP, CMR, PLTC, etc.)Installation of communications cables by building location (plenum, riser, general-purpose, dwelling)Grounding and bonding of communications systems, cable shields, and primary protectorsAntenna system installation, clearances, and grounding requirementsNetwork-powered and premises-powered broadband communications systems (Articles 830 and 840)Class 4 fault-managed power systems and energy management system controls
Iluminación3 Q · 3%
Luminaire installation requirements by location (wet, damp, corrosive, closets, bathtub/shower zones)Luminaire support methods and outlet box requirementsLuminaire grounding and wiring requirementsRecessed luminaire requirements (thermal protection, clearances, insulation contact, IC vs non-IC)Lighting track installation and restrictionsBallasts and auxiliary equipment for fluorescent and HID luminaires (thermal protection, disconnecting means)Low-voltage lighting systems (voltage limitations, secondary circuit isolation, branch circuit requirements)Lamp and light source types (incandescent, fluorescent, HID, LED) and their operating characteristics
Letreros Iluminados2 Q · 2%
Branch circuit requirements for signs (rating, dedicated circuit, and wiring methods)Disconnecting means location and lockout requirementsGrounding and bonding of sign equipment and metal partsListing, labeling, and marking requirements for signs and retrofit kitsTransformers and electronic power supplies (ratings, secondary voltage, ground-fault protection)Neon secondary-circuit wiring (≤1000V and >1000V methods, conductor types, spacing)Location restrictions (height above vehicles, combustible materials, wet location drain requirements)Portable and mobile sign requirements (cord types, GFCI, support)
Sistemas de Detección de Incendios y Alarmas2 Q · 2%
Power-limited fire alarm (PLFA) circuit wiring methods and cable types (FPL, FPLR, FPLP)Non-power-limited fire alarm (NPLFA) circuit power source and overcurrent protection requirementsBranch circuit requirements and disconnecting means identification for fire alarm systemsSeparation of PLFA conductors from power, Class 1, and NPLFA circuit conductorsFire alarm cable applications in plenums, risers, and general building locationsCircuit integrity (CI) cable and fire-resistive cable system installation requirementsAbandoned fire alarm cable removal and circuit identification requirementsNPLFA and PLFA conductor materials, sizes, and insulation requirements
Información de Seguridad5 Q · 5%
Electrical Safety Program (ESP) components and requirementsLockout/tagout (LOTO) procedures and electrically safe work conditions (ESWC)Arc flash risk assessment and PPE selection methodsShock risk assessment and approach boundaries (limited and restricted)Personal protective equipment (PPE) selection, use, and inspectionQualified vs. unqualified person requirements and safety trainingArc flash hazard warning labels and equipment markings (NEC 110.16)Working space and guarding requirements for electrical equipment (NEC 110.26, 110.27)
Protección contra Sobrecorriente6 Q · 5%
Types and classifications of fuses (plug, cartridge, Class H/J/K/L/R/T)Circuit breaker types and operating principles (thermal, magnetic, thermal-magnetic, electronic)Standard ampere ratings for fuses and circuit breakers (NEC Table 240.6(A))Overcurrent device location requirements and tap conductor rules (NEC 240.21)Ground-fault protection of equipment (GFPE) for services and feeders (230.95, 240.13)Arc energy reduction (NEC 240.87) and current-limiting overcurrent devicesInterrupting ratings and short-circuit current calculationsOvercurrent device installation requirements (accessibility, enclosures, prohibited locations)
Servicio, Alimentadores y Circuitos Ramales10 Q · 9%
Branch-circuit ratings, conductor sizing, and overcurrent protection requirementsGFCI and AFCI protection requirements by location and occupancy typeDwelling unit receptacle outlet placement and required branch circuitsService entrance conductor sizing, wiring methods, and clearancesService disconnecting means requirements, ratings, and locationFeeder conductor sizing, overcurrent protection, and identificationPanelboard, switchboard, and switchgear installation and overcurrent protectionSurge-protective device (SPD) types, installation, and connection requirements
Distinciones Clave
AnexosvsModificaciones
Las adendas son cambios que se introducen en un contrato de obra antes de la adjudicación del mismo, mientras que las modificaciones son cambios que se introducen después de la firma y la formalización del contrato.
NASCLA Contractors Guide, Contract Management chapter — Making Changes to the Contract section
ArbitrajevsMediación
En el arbitraje, un árbitro independiente dicta una resolución jurídicamente vinculante para todas las partes, mientras que en la mediación el mediador se limita a facilitar el diálogo y son las propias partes las que establecen las condiciones.
Seguro a todo riesgo para constructoresvsSeguro de riesgos de constructores con riesgos especificados
Las pólizas «a todo riesgo» cubren las pérdidas directas derivadas de cualquier riesgo que no se haya excluido expresamente, mientras que las pólizas de riesgos especificados tienen una cobertura más limitada y solo enumeran los riesgos concretos que cubren (por ejemplo, incendio y rayos).
Método de cálculo del precio unitariovsMétodo de cálculo de presupuestos basado en el levantamiento de medidas
El método del precio unitario agrupa todos los factores de coste (mano de obra, materiales, equipamiento, subcontratistas) en un único precio por tarea, mientras que el método de cálculo de cantidades estima cada componente por separado.
NASCLA Contractors Guide, Bidding and Estimating chapter — Other Methods of Estimating section
Gastos generales del proyectovsGastos generales de la empresa
Los gastos generales de proyecto están directamente vinculados a una obra concreta (por ejemplo, almacenamiento temporal, fianzas, contenedores de escombros), mientras que los gastos generales de la empresa son gastos generales de la actividad empresarial (por ejemplo, alquiler de oficinas, honorarios de contabilidad, honorarios jurídicos).
Relleno de la canaleta del ascensor (artículo 620.33)vsRelleno estándar para canaletas (Capítulo 9, Tabla 1)
En las instalaciones de ascensores, el llenado de los conductos se limita al 50 % de la sección transversal interior, mientras que en el cableado general se aplican los porcentajes de llenado establecidos en la Tabla 1 del Capítulo 9 de la norma, que difieren de esta disposición especial.
Article 620.33
Cubierta para cables de enterramiento directo (general)vsCubierta para conductos metálicos rígidos (general)
Los cables enterrados directamente requieren una profundidad mínima de 600 mm (24 pulgadas) en todos los lugares no especificados, mientras que los conductos metálicos rígidos o los conductos IMC solo requieren 150 mm (6 pulgadas) en esos mismos lugares no especificados.
NEC Table 300.5(A)
Cable para enterrar directamente bajo la entrada de un garaje residencialvsConducto metálico rígido bajo la entrada de un aparcamiento residencial
Tanto los cables enterrados directamente como los conductos metálicos rígidos situados bajo las entradas de vehículos de viviendas unifamiliares y bifamiliares (uso exclusivamente residencial) requieren la misma profundidad mínima de 450 mm (18 pulgadas).
NEC Table 300.5(A)
Longitud de la caja de tracción rectavsDistancia entre la caja de acoplamiento angular y la de tipo «U»
En el caso de los tendidos rectos, la longitud de la caja debe ser, como mínimo, 8 veces el tamaño comercial más grande del canal de cables, mientras que en el caso de los tendidos en ángulo o en U, la distancia desde cada entrada del canal de cables hasta la pared opuesta debe ser, como mínimo, 6 veces el tamaño comercial más grande del canal de cables.
NEC 314.28(A)(1)
Unidades de protección contra sobrecargas para motores monofásicos (2 hilos, sin toma de tierra)vsUnidades de protección contra sobrecargas para motores trifásicos
Un motor monofásico conectado a una red de dos hilos sin toma de tierra solo necesita una unidad de sobrecarga de marcha instalada en cualquiera de los dos conductores, mientras que un motor trifásico requiere tres unidades de sobrecarga, una en cada fase.
NEC 2023, Table 430.37
Estado de la licencia activavsEstado de licencia inactiva
El titular de una licencia vigente de contratista eléctrico de Alabama puede optar por pasar a la categoría de inactivo notificándolo a la Junta al menos 30 días antes de la fecha de caducidad; una licencia caducada no puede pasar a la categoría de inactivo en ningún caso.
Alabama Supplement to the Contractors Guide to Business, Law and Project Management, Board Administrative Code 303-X-2-.04, Inactive Status Certification
THWN-2 (90 °C) Capacidad de carga del conductorvsCapacidad de carga de los conductores con factores de ajuste
Los valores de capacidad de corriente de la tabla 310.16 (por ejemplo, 30 A para un cable THWN-2 de 12 AWG) se basan en un máximo de 3 conductores que transportan corriente a una temperatura ambiente de 30 °C; cuando hay entre 4 y 6 conductores, se aplica el factor del 80 %; entre 7 y 9 conductores, el 70 %; y entre 10 y 20 conductores, el 50 %.
NEC Table 310.16
Términos Clave
Certificado de situación inactiva (Norma 303-X-2-.04 de la Junta de Alabama) Alabama Supplement to the Contractors Guide to Business, Law and Project Management, Board Administrative Code 303-X-2-.04, Inactive Status Certification
El Código Administrativo de la Junta de Alabama 303-X-2-.04 permite a los titulares de una licencia dar de baja una licencia activa de contratista eléctrico notificándolo a la Junta por escrito o a través del formulario en línea de la Junta al menos 30 días antes de la fecha de caducidad de la licencia; las licencias caducadas no cumplen los requisitos.
Impedancia efectiva (Ze) — NEC, cap. 9, tabla 9, nota 2 National Electrical Code 2023, Chapter 9, Table 9, Note 2
Según el capítulo 9, tabla 9, nota 2 del NEC, la impedancia efectiva para un factor de potencia del circuito distinto del valor predeterminado de la tabla se calcula como Ze = R × PF + XL × sin[arccos(PF)].
Capacidad de carga de un conductor en función de la temperatura ambiente — NEC 310.16 NEC 310.16
Los valores de capacidad de carga de la tabla 310.16 del NEC se basan en una temperatura ambiente de 30 °C (86 °F); se deben aplicar factores de corrección para otras temperaturas ambiente.
Clasificación mínima del servicio — Vivienda unifamiliar (NEC 230.79(C)) NEC 230.79(C)
La norma NEC 230.79(C) exige que el dispositivo de desconexión de servicio de una vivienda unifamiliar tenga una capacidad nominal de al menos 100 amperios, en sistema de tres hilos.
Distancia libre de los conductores de servicio aéreos — Vías públicas (NEC 230.24(B)) NEC 230.24(B)
La norma NEC 230.24(B) exige que los conductores de servicio aéreos cuya tensión no supere los 1.000 V mantengan una distancia mínima de 5,5 m (18 pies) sobre las calles públicas, callejones, carreteras y zonas de aparcamiento por las que circulen camiones.
Seccional mínima del conductor de servicio aéreo (NEC 230.23(B)) NEC 230.23(B)
La norma NEC 230.23(B) prohíbe el uso de conductores de servicio aéreos de sección inferior a 8 AWG de cobre o a 6 AWG de aluminio o de aluminio revestido de cobre.
Requisitos para los conductores trenzados en canaletas (NEC 310.3(C)) NEC 310.3(C)
La norma NEC 310.3(C) exige que los conductores de 8 AWG y de sección mayor instalados en canaletas sean trenzados, salvo que el Código permita o exija expresamente que sean macizos.
Longitud libre de los conductores en las tomas de corriente (NEC 300.14) NEC 300.14
La norma NEC 300.14 exige que haya al menos 150 mm (6 pulgadas) de conductor libre, medidos desde el punto en el que sale del canal o de la funda del cable, en cada toma de corriente, empalme y punto de conmutación.
Espesor de la protección de chapa de acero (NEC 300.4(A)(2)) NEC 300.4(A)(2)
La norma NEC 300.4(A)(2) exige que los cables o canaletas tendidos en muescas en elementos de madera estén protegidos contra la penetración de clavos o tornillos mediante una placa de acero de al menos 1,6 mm (1/16 pulg.) de espesor.
Relleno de la caja — Margen de volumen del soporte del dispositivo (NEC 314.16(B)(4)) NEC 314.16(B)(4)
Cada yugo o correa que contenga uno o más dispositivos requiere una holgura de doble volumen (basada en el conductor de mayor sección conectado) a la hora de calcular el llenado de la caja.
Extensión de la funda NMC hacia el cuadro (NEC 314.17(B)(2)) NEC 314.17(B)(2)
La norma NEC 314.17(B)(2) exige que la funda de los cables con revestimiento no metálico se adentre al menos 6 mm (1/4 pulg.) en el interior de la caja y sobresalga 6 mm (1/4 pulg.) más allá del extremo de cualquier abrazadera de cable.
Límite de tamaño de las cajas de derivación con soporte de canaleta (NEC 314.23(E)) NEC 314.23(E)
La norma NEC 314.23(E) limita el tamaño máximo de las cajas que se apoyan únicamente en canaletas de entrada (y que no contienen dispositivos, luminarias ni portalámparas) a 1.650 cm³ (100 pulgadas cúbicas).
Altura máxima del tirador del interruptor (NEC 404.8(A)) NEC 404.8(A)
La norma NEC 404.8(A) exige que el centro del mango de un interruptor o de una palanca de accionamiento de un disyuntor, en su posición más alta, no se encuentre a más de 2,0 m (6 pies y 7 pulgadas) por encima del suelo o de la plataforma de trabajo.
Tipo THHN. Temperatura máxima de funcionamiento (NEC, tabla 310.4(1)) NEC Table 310.4(1)
Los conductores de tipo THHN tienen una temperatura máxima de funcionamiento de 90 °C (194 °F) en entornos secos y húmedos.
Interruptor de uso general como desconexión del motor — Regla del 200 % American Electricians' Handbook, 17th Edition, Sec. 383 (Motor switches), item 2
En el caso de motores fijos de 2 hp o menos y con una tensión máxima de 300 V, un interruptor de uso general podrá servir como medio de desconexión únicamente si su intensidad nominal es, como mínimo, el 200 % de la corriente nominal a plena carga del motor.
Fórmulas que Debes Saber
Impedancia efectiva (Ze) con un factor de potencia no estándarZe = R × PF + XL × sen[arccos(PF)]
Capacidad de corriente mínima del conductor de alimentación/servicio (cargas continuas y no continuas)Capacidad de corriente ≥ Carga no continua + (1,25 × Carga continua)
Longitud mínima de la caja de tracción rectaLongitud de la caja ≥ 8 × (tamaño comercial del canal de cableado más grande)
Caja en ángulo o tipo «U Pull» — Distancia mínima entre la entrada y la pared opuestaDistancia ≥ 6 × (tamaño comercial del canal de carrera más grande)
Ley de Ohm — Corriente totalI = E ÷ R
Capacidad de carga del conductor con ajuste de llenadoCapacidad de carga ajustada = Capacidad de carga de la tabla × Factor de ajuste (80 % para 4-6 conductores; 70 % para 7-9; 50 % para 10-20)
Nivel máximo de llenado del canal de cables del ascensorLa suma de las secciones transversales de los conductores debe ser ≤ al 50 % de la sección transversal interior del conducto.
Llenado de la caja — Margen de volumen del yugo del dispositivoRelleno del yugo = 2 × (margen de volumen para el conductor de mayor tamaño conectado al dispositivo)