Hoja de Referencia del Examen · Referencia Rápida
Alabama Marine Construction Contractor
Alabama · PSI Services Contractor
Porción Estatal de Alabama 50 preguntas
Distinciones Clave
Isolation joints extend the full depth of the slab and separate it from walls, columns, and footings to permit horizontal and vertical movement, while contraction joints extend only approximately one-quarter the slab thickness to control cracking.
Design and Control of Concrete Mixtures, Page 282Ownership costs include major repairs and overhauls (which extend machine service life), while operating costs include fuel, lubricants, and tires consumed during use.
Construction Equipment Guide, Chapter 2, Page 80Per PCSA standards, cranes on outriggers or rubber tires shall not exceed 85% of tipping load, while crawler-mounted machines are limited to 75% of tipping load.
Construction Equipment Guide, Chapter 16 - Cranes, RATED LOADS FOR LATTICE- AND TELESCOPING-BOOM CRANESLeasing is treated as an off-balance-sheet operating expense that preserves bonding capacity, while direct ownership creates a debt liability that can reduce bonding capacity.
Construction Equipment Guide, Chapter 2 - Equipment Economics, Lease considerationsType MV-90 has a maximum operating temperature of 90°C, while Type MV-105 has a maximum operating temperature of 105°C; both are suitable for dry or wet locations.
NEC Table 315.10(A)Shielded or lead-covered conductors over 1000 V must not be bent to a radius less than 12 times the overall diameter, while nonshielded conductors require a minimum of only 8 times the overall diameter.
NEC 305.5Direct-buried cables rated over 1000 V through 22 kV require 750 mm (30 in.) minimum cover, while cables over 22 kV through 40 kV installed in rigid metal conduit require only 150 mm (6 in.) minimum cover.
NEC Table 305.15(A)Danger signs—with a red upper panel, black borders, and white lower panel—shall be used only where an immediate hazard exists, distinguishing them from caution or general warning signs used for lesser hazards.
OSHA 1926 CFR 29, Page 201Type III is ground finer than Type I to achieve high early strength quickly, while Type II(MH) limits its heat index to a maximum of 100 to generate heat at a slower rate, making it suitable for mass concrete.
Design and Control of Concrete Mixtures, Page 113Type V has a low C₃A content (≤5%) specifically for severe sulfate exposure environments, while Type I is a general-purpose cement with no special sulfate resistance.
Design and Control of Concrete Mixtures, Page 113Adding fly ash generally reduces water demand in a concrete mix, while adding silica fume increases water demand.
Design and Control of Concrete Mixtures, Page 363Employers with 10 or fewer employees may communicate the plan orally and need not maintain a written document, while larger employers must maintain a written plan.
OSHA 1926 CFR 29, §1926.35(e)(3)Términos Clave
Fórmulas que Debes Saber
Suction lift = 25 ft − (Elevation in ft ÷ 1,000)Max aggregate size = Slab depth ÷ 3Max aggregate size = (3/4) × clear spacing between reinforcing barsMax aggregate size = Narrowest member dimension ÷ 5Rated load ≤ 0.85 × Tipping loadRated load ≤ 0.75 × Tipping loadContraction joint depth ≈ Slab thickness ÷ 4Length ÷ Width ≤ 1.5 (to prevent center cracking in concrete panels)