Hoja de Referencia del Examen · Referencia Rápida
Alabama Remodeling, Alteration, and Maintenance Contractor
Alabama · PSI Services Contractor
Porción Estatal de Alabama 60 preguntas
Distinciones Clave
In balloon framing, studs run continuously from sill plate to second-floor top plate with second-floor joists bearing on ribbons; in platform framing, each story is built separately with studs only one story tall.
Carpentry and Building Construction, Chapter 14 – Structural Systems, Section 14.1Coped joints are recommended for inside corners of profiled moldings like crown because they fit tightly even when walls are not perfectly square, whereas inside miters open up when walls are out of square.
Finish Carpenter's Manual, Page 84Shellac is highly color-stable, does not darken with age, and repairs easily because new coats melt into old; polyurethane is hard to repair because new coats do not self-feather into the old finish.
Finish Carpenter's Manual, Chapter 17 (Flooring)Shellac is color-stable and resists stains, while penetrating oil darkens noticeably in areas that receive less light and has poor stain resistance.
Finish Carpenter's Manual, Chapter 17 (Flooring)Parquet flooring is attached to the subfloor with mastic (a thick adhesive), whereas strip flooring is installed by blind nailing.
Carpentry and Building Construction, Page 982For glue-nailed subfloor panels with a span rating of 24 or greater, nails at supported panel edges are spaced 6 inches on center, while nails at intermediate supports are spaced 12 inches on center.
Table 15-5, page 422When roof trusses span the entire width of a house, exterior walls carry roof and ceiling loads, so interior walls serve mainly as room dividers rather than structural load-bearing members.
Carpentry and Building Construction, Chapter 16 – Wall Framing & Sheathing, Section 16.1To create a shear wall in earthquake or high-wind areas, sheathing must be nailed to all studs, blocking, and sills at 3 inches on center, a tighter spacing than standard sheathing attachment.
Carpentry and Building Construction, Section 16.1 (Book Page 437)The plate biscuit joiner has largely replaced dowel joinery in modern finish carpentry for aligning and strengthening butt joints because biscuits are faster to cut and install and hold better than dowels.
Finish Carpenter's Manual, Chapter 3 - The Power ToolsRunning molding conveniently refers to any molding item that can be ordered by the linear foot in random lengths, while standing molding is ordered in specific lengths for a specific application.
Modern Finish Carpentry, Chapter 5 — Estimating Running and Standing Moldings sectionHold-down anchors are steel brackets at corners that prevent walls from tipping over during seismic events, while shear walls (sheathing nailed at close spacing) resist lateral sliding forces across the wall plane.
Carpentry and Building Construction, Section 14.1, Page 14-12 (Book Page 379)Both types provide nailing surfaces for sheathing and wall covering and must maintain the same 16-inch or 24-inch on-center spacing as full-length studs, but upper cripples fill the space between the header and top plate while lower cripples fill the space below the rough sill.
Carpentry and Building Construction, Section 16.1 (Book Page 434)