Hoja de Referencia del Examen · Referencia Rápida
Louisiana Residential Roofing
Louisiana · PSI Services Contractor
Porción Estatal de Louisiana 50 preguntas
Distinciones Clave
Wood shingles may be Grade 1, 2, or 3 under CSSB rules, while wood shakes require a minimum of Grade 1 only.
IBC 2021, Table 1507.8.5Class A is effective against severe fire-test exposure, while Class B is effective against only moderate fire-test exposure.
IBC 2021, Section 1505.2Class B is effective against moderate fire-test exposure, while Class C is effective against only light fire-test exposure.
IBC 2021, Section 1505.3The positive method divides an irregular roof into rectangles and adds their areas, while the negative method extends roof lines into one large rectangle and subtracts non-roof areas; both yield identical results.
Roofing Construction and Estimating, Chapter 1, Pages 7-8Class G shingles are rated for basic wind speeds up to 120 mph, while Class H shingles are rated for basic wind speeds up to 150 mph.
NRCA Roofing Manual: Steep Slope Roof Systems, Section 4.1—Wind Resistance (ASTM D7158)NRCA recommends a cricket when the chimney or curbed penetration exceeds 24 inches wide, while backer flashing is generally used for penetrations 24 inches wide or less.
NRCA Roofing Manual: Steep Slope Roof Systems, Asphalt Shingle Roof Systems — Chapter 7Both asphalt shingles and slate shingles must be fastened to solidly sheathed decks; however, unlike slate, asphalt shingles also require that the deck be a wood-based material (structural wood panel, plank, or board).
IBC 2021, Section 1507.2.1Self-adhering sheets range from 20–60 mils thick, while non-self-adhering polymer-modified bitumen base sheets are thicker, ranging from approximately 35–90 mils.
NRCA Roofing Manual: Steep Slope Roof Systems, Section 3.1—Underlayment Materials (Self-adhering Polymer-modified Bitumen Sheets)ASTM D3462 covers tear strength, fastener pull-through resistance, and pliability for fiberglass-reinforced asphalt shingles, while ASTM D3018 specifically addresses Class A fire test classification, wind resistance, and loss of volatile matter.
NRCA Roofing Manual: Steep Slope Roof Systems, Section 4.1—Asphalt Shingle StandardsClay roof tile must comply with ASTM C1167, while concrete roof tile must comply with ASTM C1492.
IBC 2021, Section 1507.3.4On wood plank or board decks, asphalt shingle nails must penetrate at least ¾ inch, while on plywood decks less than ¾ inch thick, nails need only extend a minimum of ⅛ inch through the underside.
NRCA Roofing Manual: Steep Slope Roof Systems, Section 4.2—Asphalt Shingle Roof System Design and Installation (Fasteners)Impermeable synthetic underlayments have a water vapor transmission rating of less than 0.1 perms and are not recommended by NRCA over unvented or inadequately ventilated attics, while permeable underlayments exceed this threshold and are acceptable.
NRCA Roofing Manual: Steep Slope Roof Systems, Section 3.1—Underlayment Materials (Synthetic Sheets)Términos Clave
Fórmulas que Debes Saber
Total Area = Sum of all individual rectangular sections of the roofTotal Area = Area of one large enclosing rectangle − Sum of non-roof rectangular areasNumber of Squares = Total Roof Area (sq ft) ÷ 100Slope = Rise (inches) : Run (12 inches), e.g., 3:12 means 3 inches of rise per 12 inches of horizontal runAdjusted Material Quantity = Calculated Quantity × (1 + Waste Factor %)Coverage (sq ft) = Shingle exposure (inches) × Shingle width (inches) × Number of shingles ÷ 144