Verificado, no estimado. Cada cifra a continuación proviene de la estructura oficial del examen que mantenemos: número de preguntas, puntaje de aprobación y ponderación de temas. Las preguntas de práctica están fundamentadas en la ley fuente con citas de estatutos. Omitimos cualquier cifra que no podamos verificar en lugar de adivinarla.
Total de preguntas
80
Puntaje de aprobación
70%
Tiempo del examen
240 min
Administrado por
PSI Services Contractor
Formato
Se permiten materiales de referencia
Porción Estatal de South Carolina
80 preguntas
Tuberías en General1 Q · 1%
Pipe and tubing material selection (steel, copper, plastic, CSST) and applicable standardsGas piping sizing methods and pressure drop calculationsPipe joining methods (threaded, brazed, soldered, welded, flared, solvent-cemented)Pipe bending calculations (setback, length of arc, offset bends)Pipe and tubing support spacing requirementsHydronic piping system installation requirements and valve placementPressure testing and purging of piping systemsPipe fittings dimensions and laying lengths (elbows, tees, reducers, flanges)Full Text
Tubería General1 Q · 1%
ACR copper tubing types and sizing (soft vs. hard-drawn, Type K and L, nominal vs. actual OD)Cutting tubing methods and tools (tubing cutter, hacksaw, reaming and deburring)Bending tubing techniques (bending springs, lever-type benders, minimum bend radius)Flared connections (single and double flares, flaring tools, flare fittings and nuts)Soldering and brazing connections (flux application, filler metals, flame types, purging with nitrogen)Swaged connections and specialized tube couplings (swaging tools, dissimilar metal joints)Non-refrigerant piping materials (copper water tubing, plastic pipe types ABS/PVC/CPVC, steel pipe and fittings)Pipe bending calculations (setback, length of bend, offset bends, minimum bending radius for standard pipe)Full Text
Ensamblaje de Tuberías1 Q · 1%
Pipe and tubing material selection (steel, copper, plastic, CSST) by applicationJoining methods: threaded, brazed, soldered, solvent-cemented, and mechanical connectionsPipe bending calculations: setback, arc length, and offset geometryPipe sizing and gas capacity using code tables and pressure-drop equationsFitting dimensions and laying lengths for screwed, flanged, and butt-weld fittingsPipe support spacing and hanger requirementsPressure testing and purging of assembled piping systemsHydronic piping joints, valves, and installation requirements per SC Mechanical CodeFull Text
Sistemas de Tuberías2 Q · 2%
Pipe and tubing materials selection (copper, steel, plastic, CSST)Gas piping sizing methods and tablesPipe joining methods (brazing, soldering, threading, solvent cementing, flared connections)Pipe bending techniques and calculations (setback, bend length, offset bends)Hydronic piping system design and components (boilers, pumps, expansion tanks, valves)Fuel oil piping installation requirements and materialsPipe support spacing and hangersRefrigerant piping components (filter-driers, receivers, sight glasses, flow valves)Full Text
Tuberías de Drenaje1 Q · 1%
DWV copper drainage tube dimensions and applicationsPlastic pipe materials for drainage applications (ABS, PVC, butyrate)Pipe slope and drainage requirements for underground installationsPipe support spacing for drainage pipingOffset calculations and routing for drain piping installationsPipe fitting dimensions and laying lengths for drain system connectionsFull Text
Válvulas1 Q · 1%
Refrigerant service valve types, positions, and operation (back-seated, front-seated, mid-position, cracked open)Check valves: function, types, and applications in refrigeration and heat pump systemsSolenoid valves: normally open vs. normally closed, two-way and three-way configurationsMetering devices as valves: TXV operation and adjustment, AXV, EEV, capillary tubes, and fixed-orifice typesPressure-regulating valves: crankcase pressure regulators (CPRs), evaporator pressure regulators (EPRs), and relief valvesReversing valves in heat pump systems: direct-acting and pilot-operated types, heating vs. cooling mode operationHydronic system valves: mixing valves, balancing valves, pressure-reducing valves, flow-control valves, and backflow preventersValve material compatibility and pressure/temperature ratings per SC Mechanical Code hydronic piping requirementsFull Text
Aislamiento de Tuberías1 Q · 1%
Insulation characteristics and fire safety ratings (flame spread and smoke-developed index limits)Required insulation thickness per energy code compliancePipe insulation requirements for radiant floor heating systems (thermal break and R-value marking)Insulation requirements for embedded hydronic pipingCondensation prevention on exterior of pipingPipe support spacing allowances for insulated versus uninsulated linesClearance to combustibles for high-temperature hydronic pipingFull Text
Colgadores y Soportes (General)1 Q · 1%
Pipe support spacing intervals by material typeHanger and anchor attachment to building structureMaterials compatibility for pipe hangers and supportsU-bolt dimensions for pipe hangersSupport spacing for plastic pipe (PVC, ABS, polyethylene)Shield plate protection for piping in notched or bored framing membersSupport spacing for copper and steel pipeStructural strength requirements for hangers under static and dynamic loadingFull Text
Control Mecánico de Sonido, Vibración y Sísmica1 Q · 1%
Vibration isolation methods for mechanical equipment and ductworkNoise sources in HVAC systems (blower, duct turbulence, air distribution components)Noise control through duct design and air velocity limitsNoise Criteria (NC) values for occupied spacesSound attenuation techniques (duct lining, lined elbows, sound traps)Crosstalk prevention through duct geometrySeismic resistance requirements for mechanical system supports and anchorageSupplemental restraint requirements when vibration isolation is employed
Principios de Calefacción y Enfriamiento2 Q · 2%
Heat transfer methods: conduction, convection, and radiationSensible heat vs. latent heat in heating and cooling applicationsThermal resistance properties: K-value, C-value, R-value, and U-valueIndoor and outdoor design temperatures for load calculationsHeat loss and heat gain sources in building envelopesCompression refrigeration cycle: evaporation, compression, condensing, and meteringHeat pump operating principles: heating mode and cooling modePsychrometric properties of air: dry-bulb temperature, wet-bulb temperature, relative humidity, and dew point
Refrigerantes1 Q · 1%
Refrigerant classification types (CFC, HCFC, HFC, HFO, HC) and their chemical compositionsEnvironmental impact: ozone depletion potential (ODP) and global warming potential (GWP)EPA Clean Air Act Section 608 requirements and technician certification typesRefrigerant numbering system, cylinder color codes, and ASHRAE safety classifications (toxicity and flammability)Pressure-temperature charts, pressure-enthalpy tables, and diagrams for system diagnosticsRefrigerant recovery, recycling, and reclaiming procedures and equipmentRefrigerant lubricant types (MO, POE, AB, PAG) and compatibility with refrigerantsSC Mechanical Code refrigerant classification groups, allowable quantities, and machinery room requirements
Cálculos de Carga8 Q · 10%
Heating and cooling design temperature differences (HTD and CTD)Fenestration heating and cooling HTM calculations (windows, glass doors, skylights)Opaque panel heating and cooling loads (walls, ceilings, floors, doors)Infiltration load estimation methods (ACH method, component leakage area, blower door)Duct load factors (conduction, leakage, insulation R-value, surface area adjustments)Internal loads (occupants, appliances, lighting)Engineered ventilation sensible and latent loadsOutdoor and indoor design conditions (Table 1 values, grains difference, daily range, latitude)
Equipos de Calefacción y Enfriamiento1 Q · 1%
Gas-fired furnace combustion principles and efficiency (AFUE, combustion air, flue gas analysis)Gas furnace components: burners, gas valves, ignition systems, and safety controlsOil-fired heating system components, combustion testing, and fuel oil characteristicsElectric resistance heating systems: elements, furnaces, duct heaters, and controlsHydronic heating systems: boilers, circulating pumps, expansion tanks, and terminal unitsHeat pump operation, types (air-source and ground-source), efficiency ratings, and reversing valve functionResidential and commercial central air-conditioning systems: split, packaged, and rooftop unitsHeating and cooling load calculations: heat transfer values, Manual J method, and design temperatures
Pruebas, Ajuste y Balanceo (TAB)2 Q · 2%
Air-side balancing procedures and damper adjustmentAirflow measurement instruments and techniques (flow hoods, anemometers, pitot tubes, manometers)Duct leakage testing methods (blower door subtraction, duct blaster/pressurization)Blower performance curves and system operating point determinationBuilding envelope airtightness testing and ACH50 calculationSupply and return CFM measurement and verificationDuct system noise diagnosis and correctionAir filter inspection, pressure drop measurement, and service
Fundamentos de Control HVACR1 Q · 1%
Thermostat types and sensing elements (bimetal, thermistor, mercury switch, hydraulic)Heat and cooling anticipators (operation, adjustment, and purpose)Line-voltage, low-voltage, and millivolt thermostat operation and wiringProgrammable, wireless, and smart thermostat features and programmingControl system fundamentals (set point, differential, range, cut-in/cut-out adjustment)Pressure motor controls (high-pressure, low-pressure, oil pressure safety controls)Motor starting relays (current, potential, solid-state, PTC)Electrical test instruments (voltmeter, ohmmeter, ammeter, multimeter usage and procedures)
Esquemas de Control y Diagramas de Cableado1 Q · 1%
Pictorial diagrams vs. ladder diagramsControl system fundamentals: cut-in, cut-out, range, and differential adjustmentTemperature motor controls and sensing devices (sensing bulbs, bimetal devices, electronic sensors)Pressure motor controls (high-pressure, low-pressure, oil pressure, and safety controls)Motor starting relays (current, potential, solid-state, and PTC relays)Motor protection devices (fuses, circuit breakers, bimetal protection, thermistor-based protection)Electrical test instruments for diagnosing control circuits (voltmeter, ohmmeter, ammeter, multimeter)Troubleshooting and servicing motor control components (thermostats, relays, contactors)
Sistemas de Control HVACR1 Q · 1%
Thermostat types and operating principles (line-voltage, low-voltage, millivolt)Heat and cooling anticipatorsThermostat wiring terminals and diagramsProgrammable and digital thermostat operation and programmingPressure motor controls (high-pressure, low-pressure, oil pressure safety controls)Motor starting relays (current, potential, solid-state, PTC)Compressor protection devices (thermal overloads, discharge line pressure switches, crankcase pressure regulators)Heat pump control systems (reversing valve control, defrost controls, auxiliary heat)
Cuarto de Máquinas1 Q · 1%
Machinery room construction and design requirementsMandatory mechanical ventilation requirements (normal and emergency conditions)Refrigerant detector requirements and emergency ventilation activationMeans of egress requirements for machinery roomsFuel-burning appliances and open flame restrictions in machinery roomsPressure relief device and emergency pressure control system termination requirementsSpecial requirements for flammable refrigerant groups (A2, A3, B2, B3) including Class I Division 2 electrical classificationRemote control and emergency shutoff requirements for machinery room equipment
Sistemas de Aire Acondicionado6 Q · 8%
Compression refrigeration cycle fundamentals (compressor, condenser, metering device, evaporator)Types of air-conditioning systems (room units, PTACs, ductless split, central split, packaged/rooftop)Residential central air-conditioning installation and serviceCommercial rooftop and packaged outdoor unit operation and controlsHeat pump operation, components, and reversing valve functionMetering devices (capillary tube, TXV, EEV, fixed orifice) selection and operationHeating and cooling load calculations and equipment sizing (Manual J)Refrigerant classification, handling, and SC Mechanical Code requirementsCommercial Metering Devices and ValvesCommercial Air-Conditioning Systems
Bombas de Calor5 Q · 6%
Heat pump operating modes (heating vs. cooling) and refrigerant flow directionTypes of heat pumps: air-source vs. ground-source (geothermal)Reversing valve operation and configurations (direct-acting vs. pilot-operated)Heat pump system components: accumulators, compressors, and crankcase heatersMetering devices for heat pumps: TXVs, biflow valves, and flow check pistonsDefrost controls and methods: reverse cycle defrost and electric heat defrostAuxiliary heat: balance point, applications, and emergency heat operationHeat pump efficiency ratings: EER, SEER, HSPF, and COP
Hornos (Equipos de Calefacción de Aire Caliente)2 Q · 2%
Gas furnace combustion principles and fuel types (natural gas vs. LP gas)Gas furnace ignition systems (standing-pilot, intermittent-pilot, DSI, and HSI)Gas furnace safety controls (high-limit switch, rollout switch, pressure switch)Gas furnace efficiency ratings and classifications (AFUE, mid-efficiency vs. high-efficiency/condensing)Gas furnace venting categories and vent materials (Category I–IV, PVC, Class B)Oil furnace components and combustion efficiency testing (CO2, stack temperature, draft, smoke tests)Electric heating systems and controls (resistance elements, sequencers, safety cutoffs)SC Mechanical and Fuel Gas Code requirements for forced-air warm-air furnace installation (listing, dampers, return-air restrictions, duct connections)Gas-Fired Heating Systems
Chimeneas, Conductos de Humo, Ventilaciones y Conectores de Ventilación3 Q · 4%
Appliance venting categories (Category I, II, III, IV) and matching vent typesChimney and vent termination height and clearance requirementsVent connector materials, sizing, slope, and installation requirementsSizing of Category I appliance venting systems using code tablesDraft hoods, draft controls, and automatically operated vent dampersFlue lining systems for masonry chimneysAppliances not required to be ventedVenting system installation for mid-efficiency and high-efficiency gas furnaces (Class B, PVC)
Aire de Combustión2 Q · 2%
Indoor combustion air volume requirements (standard method and known air-infiltration-rate method)Outdoor combustion air opening methods (two-permanent-openings and one-permanent-opening)Combustion air duct construction and installation requirementsLouvers, grilles, and screens for combustion air openingsMechanical combustion air supply systems and appliance interlock requirementsCombustion air requirements for oil-fired and solid-fuel appliances (NFPA 31 and manufacturer instructions)Dampered combustion air openings and interlock with appliance firing cyclePrimary air, secondary air, and excess air concepts for gas-fired appliances
Conocimientos Generales de Combustibles1 Q · 1%
Properties and characteristics of natural gas vs. LP (liquefied petroleum) gasCombustion fundamentals: fuel, heat, oxygen, and products of combustionFlammability limits, air-to-fuel ratios, and excess airFuel oil grades, properties, and heating valuesCombustion efficiency testing: CO2, O2, CO content, stack temperature, and draftGas pressure measurement and units (inches water column, psi)Heating values of fuel gases and fuel oilsCarbon monoxide hazards and incomplete combustion indicators
Gas Natural1 Q · 1%
Gas piping materials and fittings (steel, copper, CSST, polyethylene)Pipe sizing methods and sizing tables for natural gas systemsGas supply pressure requirements and allowable pressure dropCombustion air requirements for gas-fired appliancesVenting systems for gas-fired appliances (Type B, chimney, direct-vent categories)Gas appliance installation requirements and prohibited locationsPressure testing and leak checking of gas piping systemsCombustion process, flame characteristics, and incomplete combustion hazards
Conocimientos y Principios Generales de Sistemas de Ductos4 Q · 5%
Available static pressure calculation and friction rate determinationTotal effective length of circulation paths including fitting equivalent lengthsAir velocity limits for supply and return duct systemsDuct system types and configurations (radial, extended plenum, reducing trunk, perimeter loop)Duct materials, construction standards, and sealing requirementsBlower performance data interpretation and operating point selectionDuct leakage effects on system performance and energy efficiencyBalancing dampers: placement, function, and airflow balancing procedures
Conversión/Equivalencias de Ductos4 Q · 5%
Round-to-rectangular duct equivalency using equal friction rate tables (Chart 9)Round-to-oval duct equivalency using equal friction rate tables (Chart 10)Friction chart variables and relationships (CFM, friction rate, diameter, velocity)Duct material roughness factors and their effect on equivalent diameter calculationsMathematical equations for converting round duct to equivalent rectangular or oval shapesFitting equivalent length concept and how fittings are expressed as equivalent duct lengthEquivalent length adjustments for varying air velocity and friction rate conditionsDuct slide rule use for determining equivalent sizes and verifying velocity limits
Dispositivos/Sistemas Mecánicos de Lámina Metálica2 Q · 2%
Duct system types and configurations (radial, extended plenum, reducing trunk, perimeter loop)Sheet metal duct construction materials, gauges, and fabrication methodsDuct joints, seams, and sealing requirements (mastic, tape, fasteners)Fire and smoke damper types, ratings, and installation requirementsRegisters, grilles, and diffusers — selection, placement, and performanceDuct insulation, vapor retarders, and thermal continuity requirementsAvailable static pressure, friction rate calculation, and total effective length (Manual D procedure)Fitting equivalent lengths and airway velocity limits
Componentes del Sistema de Ductos5 Q · 6%
Duct system types (radial, extended plenum, reducing trunk, perimeter loop)Available static pressure calculation and friction rate determinationFitting equivalent lengths and their effect on total effective lengthAir velocity limits for trunk ducts, branch ducts, and supply/return outletsBalancing dampers: placement, function, and locking requirementsDuct construction materials and minimum metal thickness requirements (SC Mechanical Code)Duct sealing requirements, leakage classes, and approved sealing methodsFire and smoke dampers in duct penetrations of rated assemblies
Ductos Metálicos3 Q · 4%
Metallic duct minimum sheet metal thickness requirements by size and pressure classificationMechanical fastening requirements for round metallic ducts (screws, rivets, lap dimensions)Joints, seams, and connections sealing methods (mastic, tape, UL 181B standards)Duct pressure classification based on static pressure ratingsDuct support requirements per SMACNA standardsUnderground metallic duct installation requirements (concrete encasement, slope, sealing)Duct sizing procedure using friction rate, available static pressure, and total effective lengthMetal duct gauge thickness and aspect ratio requirements for rectangular and round ducts
Ductos de Fibra de Vidrio1 Q · 1%
Fibrous glass duct construction standards (NAIMA and SMACNA)UL 181 listing and labeling requirements for duct boardSeams, joints, and closure systems for fibrous glass duct (UL 181A-P, 181A-M, 181A-H)Reinforcement and support requirements for duct board panelsApproved installation locations for rigid fiberglass duct boardSC Mechanical Code nonmetallic duct classification and air temperature limitsDuct board use in trunk systems with flexible runouts (sizing context)Duct insulation R-value identification and labeling on fiberglass duct board
Sistemas de Filtración1 Q · 1%
Types of air filters (disposable, washable, electrostatic, carbon, HEPA)MERV ratings and filter efficiency measurement methodsElectronic air cleaner operation and maintenanceUltraviolet germicidal (UVG) light systems for air treatmentIndoor air pollutants (solid and gaseous) targeted by filtrationFilter installation, pressure drop measurement, and replacement intervalsHeat recovery ventilators (HRV) and energy recovery ventilators (ERV)Filter pressure losses as a component of duct system static pressure calculations
Equipos y Dispositivos de Ventilación2 Q · 2%
Minimum outdoor airflow rates by occupancy type (Table 403.3.1.1)Natural vs. mechanical ventilation requirementsEnergy recovery ventilators (ERVs) and heat recovery ventilators (HRVs)Exhaust systems for specific occupancies (kitchens, dryers, garages, hazardous areas)Air intake and exhaust outlet location requirementsRegisters, diffusers, grilles, and dampersDuct construction, materials, sealing, and insulationVentilation load calculations (sensible and latent) for heating and coolingExhaust Systems
Sistemas de Extracción2 Q · 2%
Exhaust discharge location requirements and minimum separation distancesCommercial kitchen Type I and Type II hood systemsClothes dryer exhaust duct installation and length limitationsHazardous exhaust systems for flammable vapors, dusts, and toxic materialsSmoke control system design and operationMakeup air requirements for exhaust systemsVentilation system balancing, airflow measurement, and duct testingEnergy recovery ventilation systems and prohibited applications
Conocimientos Eléctricos Generales2 Q · 2%
Ohm's Law and Watt's Law calculations (voltage, current, resistance, power)Series, parallel, and series-parallel circuit analysisSingle-phase and three-phase power systemsOvercurrent protection devices (fuses, circuit breakers, GFCI)Grounding, bonding, and equipment grounding conductorsElectric motor types and starting methods (split-phase, CSIR, CSCR, PSC, shaded-pole, three-phase)Electrical test instruments (voltmeter, ohmmeter, ammeter, multimeter, megohmmeter)OSHA 1926 Subpart K electrical safety requirements for construction jobsitesSubpart K—ElectricalElectrical Control Systems
Requisitos para Instalaciones Eléctricas1 Q · 1%
Grounding and bonding requirements for electrical systems and equipmentGround-fault circuit interrupter (GFCI) requirements and applicationsOvercurrent protection devices: fuses, circuit breakers, and their ratingsWiring methods and conductor requirements for temporary and permanent installationsWorking clearances and guarding of live electrical partsDisconnecting means requirements for HVACR equipment and motorsElectrical equipment approval, listing, labeling, and marking requirementsHazardous classified location electrical installation requirementsSubpart K—Electrical
Fundamentos Eléctricos/Electrónicos1 Q · 1%
Ohm's Law and Watt's Law calculations (voltage, current, resistance, power)Series, parallel, and series-parallel circuit analysisCapacitance and capacitor types (start and run capacitors)AC vs. DC current characteristics and single-phase vs. three-phase powerMagnetism, electromagnetism, and transformer operation (step-up/step-down)Semiconductor devices (diodes, SCRs, triacs, transistors, thermistors)Electric motor types and starting methods (split-phase, CSIR, CSCR, PSC, shaded-pole, ECM, VFD)Electrical control systems (motor starting relays, pressure/temperature controls, circuit protection devices)Electrical Control Systems
Seguridad2 Q · 2%
Lockout/tagout (LOTO) procedures for electrical and mechanical systemsPersonal protective equipment (PPE) selection and useFire hazards, fire extinguisher classes, and PASS techniqueRefrigerant cylinder safety and pressure vessel handlingElectrical hazards, grounding, and GFCI protectionHazard communication, safety data sheets (SDS), and GHS pictogramsEPA Section 608 certification requirements and refrigerant handling regulationsFall protection, ladder safety, confined spaces, and safe work practices
Construcción con Clasificación Cortafuego1 Q · 1%
Fire damper and smoke damper requirements for duct penetrations of fire-resistance-rated assembliesDamper ratings, testing standards, and actuation methods (UL 555, UL 555S, temperature thresholds)Fire walls, fire barriers, fire partitions, and shaft enclosure damper placement requirementsCeiling radiation damper installation in fire-resistance-rated floor/ceiling and roof/ceiling assembliesPlenum construction materials and flame spread/smoke-developed index requirementsFire-resistance ratings for temporary buildings and indoor storage room constructionFire cutoffs, fire doors, and priority construction of fire walls during building constructionDuct penetration protection of horizontal assemblies and flexible duct restrictions at rated assembliesSubpart F-Fire Protection and Prevention
Lectura General de Planos1 Q · 1%
Reading and interpreting floor plan sketches and architectural drawingsIdentifying and recording room dimensions, orientations, and north-arrow designationMeasuring and calculating areas for walls, ceilings, floors, windows, and doorsInterpreting window and door codes and alphanumeric construction designations on plansDetermining above-grade and below-grade wall classifications from plan detailsIdentifying construction details and insulation specifications from plans and specificationsDetermining zoning requirements from architectural layout and room configurationsLocating equipment, duct runs, and utility services from plan information
Distinciones Clave
Compresor de tornillo únicovsCompresor de doble tornillo
Un compresor de tornillo simple utiliza un rotor principal que engrana con dos rotores en forma de estrella accionados por el rotor principal, mientras que los principios básicos de funcionamiento son los mismos que los de otros compresores de tornillo.
Modern Refrigeration and Air Conditioning (20th ed.), Chapter 18, Section 18.2.4 — Single Screw Compressor
Terminal de salida de gases tipo B-WvsTerminal de salida de gases tipo B o L
Un conducto de evacuación de gases de tipo B-W deberá terminar a una altura vertical de al menos 12 pies por encima de la parte inferior de la caldera de pared, mientras que los conductos de evacuación de gases de tipo B o L deberán terminar a una altura de al menos 5 pies por encima de la campana de extracción o el collarín de chimenea del aparato conectado más alto.
SC Fuel Gas Code 2021, Chapter 5 Chimneys and Vents, Section 503.6.6
Pérdida de calor HTMvsAporte térmico HTM
Un HTM de pérdida de calor es el valor U del componente multiplicado por (temperatura de diseño interior – temperatura de diseño exterior), mientras que un HTM de ganancia de calor toma esa misma diferencia de temperatura y la ajusta en función de la exposición solar y el almacenamiento de calor (y, por lo general, se consulta en una tabla).
Modern Refrigeration and Air Conditioning (20th ed.), Page 992
Terminal O del termostatovsTerminal B del termostato
O activa la válvula de inversión para el modo de refrigeración y B la activa para el modo de calefacción; una válvula de inversión que debe activarse en el modo de refrigeración se conecta a O (los terminales combinados se indican como O/B).
Modern Refrigeration and Air Conditioning (20th ed.), Page 1102 — Section 40.5.1 Temperature Controls
Activación del control termostático del ventiladorvsDispositivo de desconexión termostática del ventilador
El control cierra sus contactos y pone en marcha el ventilador cuando la temperatura del plenum alcanza unos 140 °F (60 °C), y abre sus contactos tras la parada del quemador, cuando el plenum se enfría hasta unos 90 °F (32 °C).
Modern Refrigeration and Air Conditioning (20th ed.), Page 1029
Quemador de alta potenciavsQuemador de gas atmosférico (de cinta, ranurado, de inyección)
Un quemador de alta potencia utiliza un soplador para impulsar tanto el aire primario como el secundario hacia el tubo del quemador y es necesario para la combustión de fuelóleo, mientras que los quemadores de gas atmosféricos se basan en la acción de sifón o venturi del gas a través de un orificio y se utilizan con gas combustible.
Modern Refrigeration and Air Conditioning (20th ed.), Page 1124
Válvula de retención oscilantevsVálvula de retención de elevación
Una regla de selección segura consiste en combinar válvulas de retención oscilantes con válvulas de compuerta, ya que el flujo es recto, y combinar válvulas de retención de elevación con válvulas de globo y de ángulo, ya que el diseño de las válvulas de retención de elevación requiere un cambio en la dirección del flujo.
Válvula de compuerta dividida (de doble disco)vsVálvula de compuerta con cuña maciza
El modelo de disco dividido o doble debe instalarse con el vástago en posición vertical y el volante hacia arriba para evitar que se atasque el mecanismo de separación de los discos, mientras que el modelo de cuña maciza puede instalarse en cualquier posición sin riesgo de que se atasquen los discos.
Longitud de colocación «Dimensión A»vsLongitud de colocación «Dimensión 2 × A»
Las válvulas de compuerta y las válvulas de retención oscilantes con extremos para soldadura a tope (así como las válvulas de compuerta con bridas) utilizan la «dimensión A», mientras que las válvulas de globo y las válvulas angulares de acero con extremos para soldadura a tope utilizan «2 × A».
Pipefitter's Handbook (3rd ed.), Chapter 1 (Full Text), Laying Lengths of Steel Globe and Angle Valves With Butt Welding Ends
PVC de tipo I (resistencia normal al impacto) soldado con disolventevsPVC de tipo II soldado con disolvente
No es necesaria la compensación térmica cuando la diferencia entre las temperaturas extremas de funcionamiento y la temperatura de instalación no supera los ±30 grados en el caso del Tipo I, frente a los 25 grados del Tipo II.
Pipefitter's Handbook (3rd ed.), Page 3-25
Sistema de lubricación a presiónvsSistema de lubricación por salpicadura
La lubricación a presión hace que el aceite a presión llegue a todas las superficies de los cojinetes, de modo que el compresor funciona de forma más silenciosa incluso con holguras mayores en los cojinetes, ya que la película de aceite a presión amortigua los cojinetes; un sistema por salpicadura no cuenta con este colchón de aceite a presión.
Modern Refrigeration and Air Conditioning (20th ed.), Chapter 18, Section 18.3.4 — Pressure Lubrication
El casquillo es 4 pulgadas más grande que el tubovsEl casquillo mide 2 pulgadas más que el tubo
En el caso de los aparatos homologados con campanas de tiro (y los aparatos homologados para conductos de tipo B) que atraviesen una pared combustible con un tubo de pared simple, el casquillo de ventilación deberá tener un diámetro no inferior a 4 pulgadas mayor; este valor se reducirá a no menos de 2 pulgadas mayor únicamente cuando haya un tramo de conducto al aire libre de al menos 6 pies entre la salida de la campana de tiro y el casquillo (6 pulgadas para aparatos no homologados con campanas de tiro; 12 pulgadas para aparatos residenciales y de baja potencia).
SC Fuel Gas Code 2021, Chapter 5 — Section 503.7.7 (Single-Wall Penetrations of Combustible Walls)
Aumentar el diferencial del termostatovsReducción del diferencial del termostato
Si se modifican por igual los valores de activación y desactivación en direcciones opuestas, la temperatura media se mantiene sin cambios; al ampliar el diferencial (por ejemplo, 26 °F/14 °F en lugar de 25 °F/15 °F), se alarga el tiempo de funcionamiento y el intervalo entre ciclos, mientras que al reducirlo se obtienen ciclos más cortos y frecuentes.
Modern Refrigeration and Air Conditioning (20th ed.), Pages 355–357 (Section 16.2.2 Differential Adjustment)
Unidad de control principal de una caldera de gasóleovsMódulo de control de encendido de una caldera de gas
Son dispositivos equivalentes que secuencian el funcionamiento de los componentes para el encendido y supervisan dicho funcionamiento: las unidades de control principales se utilizan en calderas de gasóleo y los módulos de control de encendido, en calderas de gas.
Modern Refrigeration and Air Conditioning (22nd ed.), Page 810 — Primary Control Units (Pro Tip: Gas and Oil Furnace Controls)
Persona capaz de identificar los riesgos existentes y previsibles en el entorno o en las condiciones de trabajo que resulten insalubres, peligrosas o que supongan un riesgo para los empleados, y que esté autorizada a adoptar medidas correctoras inmediatas para eliminarlos (no se requiere ningún título, experiencia ni certificado específico).
Circuito de clase 2 Modern Refrigeration and Air Conditioning (22nd ed.), Page 277 — Electrical Codes / Class 2 circuits
Circuito alimentado por una fuente de alimentación con una tensión de salida no superior a 30 V y una potencia de 1000 VA, que abarca el cableado entre la fuente de alimentación y el equipo conectado; los circuitos de termostato y de control remoto son ejemplos típicos de circuitos de Clase 2 que el personal especializado en HVACR está autorizado a instalar (pero no los conductores de derivación, de alimentación ni de servicio).
Tubo de ventilación de gas tipo B-W SC Fuel Gas Code 2021, Chapter 5 Chimneys and Vents, Section 503.6.6
Un conducto de ventilación de gases para una caldera mural que deberá terminar a una altura vertical de al menos 12 pies por encima de la parte inferior de la caldera mural.
Longitud máxima del conducto de salida de la secadora (método de longitud especificada) SC Mechanical Code 2021, Chapter 5 Exhaust Systems, Sections 504.9.4.1 and 504.9.5
Según el Código Mecánico de Carolina del Sur 504.9.4.1, el conducto de escape no deberá superar los 35 pies, medidos desde la conexión con el conducto de transición hasta el terminal de salida, con las reducciones de los accesorios indicadas en la Tabla 504.9.4.1; La sección 504.9.5 exige una etiqueta permanente que identifique la longitud equivalente cuando esta supere los 35 pies.
Abertura de entrada de aire de compensación de la secadora (armario) SC Mechanical Code 2021, Chapter 5 Exhaust Systems — Section 504.7 Makeup Air
Según el Código Mecánico de Carolina del Sur, artículo 504.7, las instalaciones con un caudal de extracción superior a 200 cfm deben contar con aire de reposición, y un armario diseñado para una secadora de ropa debe tener una abertura de al menos 100 pulgadas cuadradas (0,0645 m²) en el recinto del armario, a menos que el aire de reposición se suministre por otros medios homologados.
Activación del extractor de cocina de tipo I mediante sensores SC Mechanical Code 2021, Chapter 5, Section 507.1.1 (Operation)
De acuerdo con el Código Mecánico de Carolina del Sur, artículo 507.1.1, cuando los sensores de temperatura o de energía radiante activen el extractor de campana de tipo I, este deberá ponerse en marcha en un plazo máximo de 15 minutos tras el encendido del primer electrodoméstico al que dé servicio dicha campana.
Cobertura de los extintores (29 CFR 1926.150(c)(1)(i)) OSHA 1926.150(c)(1)(i)
Se deberá disponer de un extintor con una capacidad nominal no inferior a 2A por cada 3.000 pies cuadrados de superficie protegida del edificio, o fracción significativa de la misma.
Sistema de alarma contra incendios en obras de construcción (29 CFR 1926.150(e)) OSHA 1926.150(e)(1) and (e)(2)
La empresa deberá instalar un sistema de alarma, como un sistema telefónico o una sirena, para que se pueda alertar a los empleados que se encuentren en las instalaciones y al cuerpo de bomberos local en caso de emergencia; el código de alarma y las instrucciones para dar aviso deberán estar expuestos de forma visible junto a los teléfonos y en las entradas de los empleados.
Inspección del botiquín de primeros auxilios (29 CFR 1926.50) OSHA 1926 CFR 29, Page 33
La empresa deberá comprobar el contenido del botiquín de primeros auxilios antes de que este se envíe a cada obra y, como mínimo, una vez a la semana en cada obra, para asegurarse de que se repongan los artículos consumidos.
Edificio provisional situado en el interior de otro edificio (29 CFR 1926.151(b)(2)) OSHA 29 CFR 1926, §1926.151(b)(2)
Las construcciones temporales situadas en el interior de otro edificio o estructura deberán ser de material incombustible o, si son de material combustible, deberán tener una resistencia al fuego de al menos 1 hora.
Líquido inflamable en los umbrales de los almacenes (29 CFR 1926.152(b)(4)(ii)) OSHA 29 CFR 1926, §1926.152(b)(4)(ii)
Las aberturas hacia otras estancias o edificios deberán contar con umbrales elevados o rampas incombustibles y estancos a los líquidos, de al menos 4 pulgadas de altura (o bien que el suelo de la zona de almacenamiento se encuentre al menos 4 pulgadas por debajo del suelo circundante), provistas de puertas cortafuegos homologadas de cierre automático; una zanja con rejilla abierta que drene hacia un lugar seguro es una alternativa admisible.
Límite de ruido impulsivo o de impacto (29 CFR 1926.52(e)) OSHA 29 CFR 1926, §1926.52(e)
La exposición de los trabajadores al ruido impulsivo o de impacto no debe superar los 140 dB de nivel de presión acústica máximo, un límite independiente de los niveles de exposición continua en función de la duración que figuran en la tabla D-2.
Capacidad nominal por hora de la compuerta cortafuegos Modern Refrigeration and Air Conditioning (20th ed.), Page 767
La resistencia al fuego de las compuertas cortafuegos debe ser del 75 % de la resistencia al fuego de la pared, el suelo o la tabique que atraviesen (una barrera de 2 horas requiere una compuerta de 1,5 horas).
Espacio libre (compresor alternativo) Modern Refrigeration and Air Conditioning (20th ed.), Chapter 18, Section 18.2.1 — Clearance Space
El pequeño volumen que queda entre el pistón en el punto muerto superior y la placa de válvulas, de aproximadamente 0,010″ a 0,020″ (de 0,254 mm a 0,508 mm).
Depósito compensador de carga Modern Refrigeration and Air Conditioning (20th ed.), Page 1089
Un depósito situado en una bomba de calor que almacena el exceso de refrigerante líquido; la tubería de gas solo atraviesa el depósito sin desembocar en él, mientras que la tubería de líquido, más pequeña, se conecta al depósito y lo llena durante el modo de calefacción.
Aire acondicionado de consola Modern Refrigeration and Air Conditioning (22nd ed.), Page 469 (Section 22.4, Console Air Conditioners)
Un sistema completo de aire acondicionado instalado en un armario vertical (unidad terminal compacta vertical) con la unidad de condensación en una sección y el ventilador/evaporador en otra, fabricado con capacidades que van desde 1/2 ton hasta 4 toneladas.
Caldera de gas de categoría II Modern Refrigeration and Air Conditioning (20th ed.), Page 1134
Una clasificación de ventilación de calderas para presión de ventilación negativa con gases de combustión condensados (gases de combustión por debajo de su punto de rocío), que requiere un material de ventilación especial especificado por el fabricante; La categoría I corresponde a presión negativa sin condensación (conducto de clase B), la III a presión positiva sin condensación (acero inoxidable) y la IV a presión positiva con condensación (PVC).
Limitación de la recuperación dependiente del sistema (pasiva) Modern Refrigeration and Air Conditioning (20th ed.), Appendix G — Type II (high- or very high-pressure appliances), Recovery Requirements, Page 1570
Según los requisitos de recuperación de tipo II de la sección 608 de la EPA, queda prohibido el uso de equipos de recuperación dependientes del sistema en cualquier instalación que contenga más de 15 lb de refrigerante (5 lb definen un pequeño electrodoméstico, 50 lb activan los requisitos de reparación de fugas y 200 lb modifican los niveles de vacío de evacuación requeridos).
Fórmulas que Debes Saber
Multiplicador de transferencia de calor (HTM) para un componenteHTM = U × HTD (temperatura de diseño interior − temperatura de diseño exterior); ejemplo: 0,07 × 50 = 3,50 Btuh/pie cuadrado, y 0,07 × 75 = 5,25 Btuh/pie cuadrado
Carga térmica a través de una superficieQ = U × Superficie × TD = Superficie × HTM; ejemplos: 136 pies cuadrados × 3,50 = 476 Btuh; 60 pies cuadrados × (0,30 × 50 = 15,00) = 900 Btuh; 140 pies cuadrados × (0,03 × 50 = 1,50) = 210 Btuh; puerta de 20 pies cuadrados × (0,50 × 70 = 35,00) = 700 Btuh
Superficie neta de pared expuestaSuperficie neta de la pared = (longitud de la pared × altura de la pared) − superficie de la ventana − superficie de la puerta; ejemplos: (24 × 9) − (2 × 30) − 20 = 136 pies cuadrados; (32 × 9) − (3 × 20) − 20 = 208 pies cuadrados
Flujo de aire por infiltración derivado de los recambios de aireCFM = ACH × volumen de la estancia ÷ 60; ejemplo: 0,6 × (16 × 14 × 10 = 2.240 pies cúbicos) ÷ 60 = 22,4 cfm
Carga térmica por infiltración y carga total de la estanciaCarga por infiltración = 1,1 × ACF × CFM × HTD (ejemplo: 1,1 × 1,00 × 22,4 × 70 = 1.725 Btuh); carga total de la estancia = pared + acristalamiento + puerta + techo + infiltración (ejemplo: 770 + 1 155 + 700 + 470 + 1 725 = 4 820 Btuh). Ajustar a un día de diseño más frío: cada componente es proporcional a HTD, por lo que 4.820 × (80 ÷ 70) = 5.509 Btuh.
Longitud equivalente total del conducto y pérdida por fricciónTEL = suma de las longitudes rectas + longitudes equivalentes de los codos (ejemplo: 28 + 22 + 15 = 65 pies rectos; 2 codos × 25 pies = 50 pies; TEL = 115 pies). Pérdida por fricción = (TEL ÷ 100) × coeficiente de fricción = (115 ÷ 100) × 0,10 pulgadas de columna de agua = 0,115 pulgadas de columna de agua.
Temperatura del aire mezclado y porcentaje de aire exteriorT_mix = (CFM de retorno × temperatura de retorno + CFM exterior × temperatura exterior) ÷ CFM total; ejemplo: (3.000 × 60 + 1.000 × 92) ÷ 4.000 = 68,0 °F. OA% = CFM de aire exterior ÷ CFM total = 1.000 ÷ 4.000 = 25 %. CFM total mezclado = suma de los caudales de entrada (3.000 + 1.000 = 4.000 CFM).
Capacidad de carga mínima del circuito (MCA)MCA = 1,25 × (FLA/RLA del motor de mayor potencia) + suma de las demás cargas; ejemplo: 1,25 × 24,0 A + 2,1 A = 32,1 A (en la placa de características se redondea a 32 A)
Carga adicional de refrigerante para un juego de tuberías largo (valores extraídos de los datos facilitados sobre el juego de tuberías)Pies adicionales = longitud total del juego de tubos − la longitud cubierta por la carga de fábrica; cargo adicional = pies adicionales × la tarifa indicada en onzas por pie; ejemplo de la figura (la carga de fábrica cubre los primeros 15 pies, 0,6 oz/pie): 65 − 15 = 50 pies; 50 × 0,6 = 30,0 onzas = 30,0 ÷ 16 = 1,9 libras
Expansión térmica de las tuberías según la tabla de expansión por cada 100 piesExpansión = (valor de la tabla a la temperatura de funcionamiento − valor de la tabla a la temperatura de instalación) por cada 100 pies × (longitud ÷ 100); ejemplo para el acero: 3,245 (400 °F) − 0,449 (60 °F) = 2,796 pulgadas por cada 100 pies; 5,0 × 2,796 = 13,98 pulgadas para 500 pies
Lectura del amperímetro de pinza de bajo amperajeCorriente real = lectura mostrada ÷ número de vueltas del cable alrededor de las mordazas del amperímetro (por ejemplo, diez vueltas indican un valor diez veces mayor); no se recomienda para cables de 10 AWG o de mayor sección.
Retroceso en un codo de tubería de 150°Retroceso = Radio × 3,73 (2,41 corresponde a curvas de 135°, 1,732 a curvas de 120° y 3,14 es el multiplicador de la longitud de la curva para curvas de 180°)
Ajuste del dispositivo de corte de seguridad por alta presiónAjuste de desconexión = presión de cabezal normal + 20 % (solo dispositivo de seguridad; el termostato o el control de baja presión activan y desactivan el compresor en condiciones normales de funcionamiento)