Hoja de Referencia del Examen · Referencia Rápida

Virginia Journeyman Electrician

Virginia  ·  PSI Services Contractor

Verificado, no estimado. Cada cifra a continuación proviene de la estructura oficial del examen que mantenemos: número de preguntas, puntaje de aprobación y ponderación de temas. Las preguntas de práctica están fundamentadas en la ley fuente con citas de estatutos. Omitimos cualquier cifra que no podamos verificar en lugar de adivinarla.
Total de preguntas
70
Puntaje de aprobación
70%
Tiempo del examen
210 min
Administrado por
PSI Services Contractor
Formato
Se permiten materiales de referencia

Porción Estatal de Virginia 70 preguntas

Normas de Práctica 3 Q · 4%
Contractor license classifications and contract value thresholds (Class A, B, C)Prohibited acts and penalties for unlicensed contractingGrounds for license denial, suspension, or revocationExemptions from contractor licensing requirementsLicense application requirements and designated employee responsibilitiesLicense expiration, renewal, and reinstatement proceduresAuthority Having Jurisdiction roles and enforcement powers under NEC Annex HElectrical permit requirements, inspections, and approval procedures
Normas de Conducta 2 Q · 3%
Grounds for disciplinary action by the boardProhibited acts resulting in disciplinary actionNegligence or incompetence in licensed professionMisrepresentation and false promisesAiding or abetting unlicensed contractorsCriminal conviction reporting requirementsFailure to obtain required permits or inspectionsAbandonment of contracted work
Renovación y Reintegración 2 Q · 3%
License expiration periods for electricians (three-year term)Continuing education requirements for electrical license renewal (three hours, code changes)Renewal fees for tradesman license ($160)Reinstatement fees for tradesman license ($210) and reinstatement window (within 30 days of expiration)Maximum reinstatement period (24 months) and requirement to reapply after expirationRenewal notice procedures and regulant obligation to renew regardless of notice receiptBoard authority to deny renewal for same reasons as initial licensure refusal or discipline
Definiciones 1 Q · 1%
Definitions of accessibility terms (accessible, readily accessible, concealed, exposed)Grounding and bonding terminology (grounded conductor, grounding electrode, bonding jumper types, equipment grounding conductor)Branch circuit types and definitions (general-purpose, individual, multiwire, appliance)Overcurrent protection terms (overcurrent, overload, fault current, interrupting rating, selective coordination)Service and feeder terminology (service point, service conductors, service drop, service lateral, feeder)Location classifications (damp, dry, wet locations) and enclosure-related terms (enclosed, guarded, weatherproof, watertight)Dwelling and occupancy definitions (dwelling unit, one-family, two-family, multifamily, bathroom, kitchen, guest room)Protection device definitions (AFCI, GFCI, surge-protective device, circuit breaker types)
Requisitos para Obtener Licencia 1 Q · 1%
Education and experience combinations required for journeyman electrician licensureDefinition of journeyman electrician and scope of electrical workMinimum age and general application requirements for licensureVerification of experience and formal vocational training documentationExemptions from examination for journeyman electrician licensureContinuing education credit allowable toward formal vocational training hoursDisclosure of criminal convictions and prior disciplinary actions on applicationsOut-of-state licensure and substantial equivalency requirements
Revocación de Licencia 1 Q · 1%
Grounds for revocation or suspension of a license or certificationProhibited acts that may result in disciplinary actionBoard authority to revoke, suspend, or deny license renewalRevocation of permits due to code violations or misrepresentationEffect of revocation on eligibility for future licensureNotification requirements upon revocation or suspension by another jurisdictionSubstantial identity of interest as grounds for revocationRevocation and suspension of inspector authority by the Electrical Board
Conocimientos Eléctricos Generales 3 Q · 4%
NEC Article 100 definitions and terminologyBranch circuit types, ratings, and requirementsOvercurrent protection devices and their applicationGrounding and bonding terminology and conceptsService entrance conductors and service equipmentGFCI and AFCI protection requirementsFeeder conductor sizing and load calculationsWorking space and equipment installation requirements
Requisitos para Instalaciones Eléctricas 2 Q · 3%
Equipment approval, examination, and listing requirementsWorking space and clearance dimensions around electrical equipmentElectrical connections, conductor terminations, and temperature limitationsConductor materials, sizes, and wiring integrityMarking requirements for equipment, hazard labels, and disconnecting meansGuarding of live parts and arc-flash hazard warningEnclosure type selection for indoor and outdoor useUnderground installation cover requirements and protection
Fundamentos Eléctrico-Electrónicos 2 Q · 3%
Grounding and bonding requirements for electrical systems (Article 250)Grounding electrode system types, installation, and sizingEquipment grounding conductor types, identification, and sizingConductor types, insulation ratings, ampacity tables, and temperature limitations (Article 310)Working space, clearances, and guarding of live parts around electrical equipment (Article 110)Identification and use of grounded conductors (Article 200)Bonding of piping systems, structural metal, and service equipmentSurge-protective devices and overvoltage protection (Article 242)
Circuitos Ramales 4 Q · 6%
GFCI protection requirements by location for dwelling and non-dwelling unitsAFCI protection requirements for dwelling units and other occupanciesBranch circuit ratings and permissible loads for 15, 20, 30, 40, and 50-ampere circuitsRequired branch circuits in dwelling units (small appliance, laundry, bathroom, garage)Minimum conductor ampacity and sizing for branch circuitsMultiwire branch circuit requirements including disconnecting means and line-to-neutral loadsReceptacle outlet placement and spacing requirements in dwelling unitsBranch circuit voltage limitations by occupancy and equipment type
Acometidas y Alimentadores 5 Q · 7%
Service disconnecting means location, rating, and maximum numberService-entrance conductor sizing, ampacity, and wiring methodsFeeder disconnecting means for buildings supplied by feeders or branch circuitsService and feeder overcurrent protection requirements and locationGrounding of service-supplied AC systems and grounding electrode conductorsNumber of services and feeders permitted and exceptions for additional suppliesOverhead and underground service conductor clearances and installation requirementsFeeder and service load calculations including demand factors for dwellings and other occupancies
Puesta a Tierra y Unión 6 Q · 9%
Grounding electrode system types, installation, and sizing requirementsEquipment grounding conductor types, sizing, and identificationBonding requirements for services, piping systems, and structural metalMain bonding jumper and system bonding jumper requirementsGrounding of service-supplied and separately derived AC systemsEffective ground-fault current path requirementsGrounding electrode conductor installation, sizing, and connection methodsGrounding and bonding of DC systems and high-impedance grounded neutral systems
Conductores y Cables 7 Q · 10%
Conductor ampacity tables and temperature ratings (Table 310.16, 310.17, 310.18, 310.19)Ambient temperature correction factors and adjustment factors for more than three current-carrying conductorsConductor insulation types, applications, and permitted uses by location (dry, damp, wet, direct burial, sunlight exposure)Minimum conductor sizes, materials, and stranding requirementsConductors in parallel: requirements and restrictionsConductor and cable marking requirementsCable type uses permitted and not permitted (NM, NMC, AC, MC, MI, SE, USE, UF)Single-phase dwelling service and feeder conductor sizing (Table 310.12)
Canalizaciones y Cajas 7 Q · 10%
Box fill calculations and conductor count requirements (Article 314.16)Pull and junction box sizing for straight pulls and angle/U pulls (Article 314.28)Securing and supporting requirements for conduit types (EMT, RMC, IMC, FMC, PVC)Physical protection of cables and raceways through wood members, framing, and structural elements (Article 300.4)Underground installation requirements and minimum cover depths (Table 300.5)Uses permitted and not permitted for specific raceway types (EMT, RMC, IMC, FMC, PVC, LFMC)Protection against corrosion for raceways and boxes in various environments (Article 300.6)Wiring in ducts, plenums, and other air-handling spaces (Article 300.22)
Ocupaciones Especiales 3 Q · 4%
Area classification for hazardous (classified) locations in specific occupancies (commercial garages, aircraft hangars, motor fuel dispensing facilities, bulk storage plants, spray application areas, health care facilities)Wiring methods and equipment requirements within classified and non-classified areas of special occupanciesGrounding and bonding requirements specific to special occupanciesSealing requirements at boundaries of Class I hazardous locations in special occupanciesEssential electrical systems (EES) for health care facilities including life safety, critical, and equipment branchesGFCI protection requirements in special occupancies including health care facilities, swimming pools, spas, and fountainsSwimming pools, spas, hot tubs, and fountain electrical installations including bonding, grounding, and luminaire requirementsEmergency disconnects, special equipment restrictions, and battery charging limitations in hazardous occupancies
Equipos Especiales 2 Q · 3%
GFCI protection requirements for pools, spas, hot tubs, and fountainsBonding and grounding requirements for aquatic installationsReceptacle placement and protection distances for pools and spasDisconnecting means for elevators, escalators, and similar equipmentWiring methods for elevator hoistways, machine rooms, and carsOvercurrent protection for electric welders and arc welding equipmentElectric vehicle supply equipment (EVSE) installation and branch circuit requirementsEmergency shutoff and safety requirements for spas and hot tubs
Letreros Eléctricos e Iluminación de Contorno 1 Q · 1%
Neon secondary-circuit wiring methods and conduit requirements over 1000 voltsTransformer and electronic power supply ratings and secondary-circuit ground-fault protectionElectrode connections, enclosures, and support requirements for neon tubingClass 2 power sources and secondary wiring for sign illumination systemsNeon secondary-circuit wiring 1000 volts or less and conductor insulation requirementsDisconnecting means and grounding requirements for electric signsPhotovoltaic-powered sign wiring, equipment listing, and disconnecting meansRetrofit kit installation requirements and field-installed skeleton tubing
Motores y Controles 5 Q · 7%
Motor branch-circuit conductor ampacity requirements (125% rule for single motors)Motor branch-circuit short-circuit and ground-fault protective device ratings (Table 430.52)Motor overload protection requirements and trip current percentages (430.32)Disconnecting means location, type, and ampere rating requirements (430.102, 430.109, 430.110)Motor controller ratings, design requirements, and types (430.82, 430.83)Conductors for multiple motors and combination loads (430.24)Motor control circuit overcurrent protection and wiring requirements (430.72, 430.74)Motor feeder short-circuit and ground-fault protection ratings (430.62)
Equipos de Utilización 4 Q · 6%
Luminaire installation requirements by location (wet, damp, corrosive, closets, bathtubs)Appliance branch-circuit sizing and overcurrent protection requirementsDisconnecting means for appliances, motors, and fixed heating equipmentMotor branch-circuit conductor ampacity and overload protectionAir-conditioning and refrigerating equipment branch-circuit and disconnecting means requirementsFixed electric space-heating equipment branch-circuit sizing and overcurrent protectionLuminaire support, grounding, and wiring methodsGenerator installation, overcurrent protection, and disconnecting means
Iluminación 2 Q · 3%
Luminaire installation in specific locations (wet, damp, corrosive, bathtub/shower areas)Luminaires in clothes closets — permitted types and clearance requirementsRecessed luminaire requirements — clearance, thermal protection, and insulation contact (Type IC vs. non-Type IC)Luminaire support methods — outlet boxes, suspended ceilings, poles, and fasteningGrounding of luminaires and lighting equipmentWiring of luminaires — conductor insulation, polarization, splices, and temperature ratingsLighting track installation — permitted locations, connected load, support, and constructionLow-voltage lighting systems (Article 411) — voltage limits, listing, secondary circuit requirements, and branch circuit
Requisitos Generales de Bajo Voltaje 1 Q · 1%
Scope and voltage limits for low-voltage lighting systems (Article 411)Listing requirements and system components for low-voltage lightingSecondary circuit requirements: grounding, isolation, and bare conductorsSpecific location requirements including walls, floors, and proximity to waterBranch circuit supply requirements for low-voltage lighting systemsCircuits and equipment operating at less than 50 volts (Article 720) conductor and receptacle requirementsClass 2 and Class 3 power source requirements and circuit classificationsSeparation of Class 2 and Class 3 circuits from power and Class 1 conductors
Sistemas de Comunicación 1 Q · 1%
Grounding and bonding requirements for communications cables and primary protectors (Article 800/805)Cable types, listings, and permitted applications by location (plenum, riser, general-purpose, limited-use)Separation requirements between communications cables and electric light/power conductorsOverhead aerial communications wires and cables entering buildings (clearances and installation)Primary and secondary protector requirements and placement for communications circuitsInstallation methods within buildings including raceways, cable routing assemblies, and cable traysCATV coaxial cable systems grounding and installation requirements (Article 820)Network-powered broadband communications systems power limitations and cable classifications (Article 830)
Sistemas de Detección de Incendios y Alarmas 1 Q · 1%
Non-power-limited fire alarm (NPLFA) circuit power source and branch circuit requirementsFire alarm circuit classification: NPLFA vs. PLFAOvercurrent protection for NPLFA circuit conductorsFire alarm circuit identification and marking at terminal and junction locationsMechanical execution of work and cable support requirements for fire alarm circuitsSeparation of fire alarm cables from other circuit conductorsFire alarm circuit integrity (CI) cable installation and support requirementsAbandoned fire alarm cable removal requirements
Seguridad 4 Q · 6%
Lockout/tagout program requirements and employer responsibilitiesEstablishing and verifying an electrically safe work conditionArc flash risk assessment and arc flash boundaryPersonal protective equipment (PPE) selection and arc flash PPE categoriesElectric shock risk assessment and approach boundaries (limited and restricted)Energized electrical work permit requirements and exemptionsSafety-related work practices and other precautions for personnelSafety-related maintenance requirements for electrical equipment

Distinciones Clave

Normas obligatorias del NECvsNormas permisivas del NEC

Las normas obligatorias utilizan «deberá» o «no deberá» e identifican acciones específicamente exigidas o prohibidas, mientras que las normas permisivas utilizan «se permitirá» o «no se exigirá».

NEC 2020, Section 90.5(A)
Una sola varilla de tierra (≤25 Ω)vsUna sola varilla de tierra (>25 Ω)

Si una sola varilla de puesta a tierra presenta una resistencia a tierra igual o inferior a 25 ohmios, no se requiere ningún electrodo suplementario; si supera los 25 ohmios, se debe añadir un electrodo suplementario.

NEC, Section 250.53(A)(2)
Motores para máquinas de accionamiento de ascensores y montacargasvsMotores de las máquinas de accionamiento de escaleras mecánicas y pasillos rodantes

Los motores de los equipos de accionamiento de ascensores y montacargas están clasificados para servicio intermitente según la norma 620.61(B)(1), mientras que los motores de los equipos de accionamiento de escaleras mecánicas y pasillos rodantes están clasificados para servicio continuo según la norma 620.61(B)(2).

NEC 2020, Section 620.61(B)(2)
Punto de serviciovsCableado de locales

El punto de servicio es la línea divisoria en la que terminan las instalaciones de la empresa de servicios públicos y comienza el cableado del inmueble, siendo la empresa de servicios públicos la encargada de determinar su ubicación; el cableado del inmueble es todo lo que se encuentra en el lado del cliente a partir de ese punto.

NEC 2020, Article 100 (Definitions, Part I — Service Point)
Contratista de clase A (Virginia)vsContratista de clase B/C (Virginia)

Un contratista de clase A ejecuta o gestiona obras en el marco de un único contrato o proyecto por un valor igual o superior a 150 000 dólares (o igual o superior a 1 millón de dólares en cualquier periodo de 12 meses); las clases inferiores se encargan de proyectos de menor valor.

Virginia Board for Contractors, Individual License and Certification Regulations, Code of Virginia § 54.1-1100
Solicitante de puesto de oficial con 240 horas de formación regladavsSolicitante de puesto de oficial sin formación reglada

Un aspirante con 240 horas de formación profesional reglada necesita 4 años de experiencia práctica para presentarse al examen de oficial de Virginia, mientras que uno sin formación reglada necesita 8 años.

Virginia Board for Contractors, Individual License and Certification Regulations, Page 11 (Part II - Entry, 18 VAC 50-30-39(B))
Restablecimiento de la licencia (Virginia)vsRenovación de la licencia (Virginia)

Una licencia restablecida se considera como si el titular hubiera mantenido la licencia de forma ininterrumpida (lo que lo mantiene bajo la autoridad disciplinaria del colegio durante todo el período de interrupción), mientras que una renovación oportuna simplemente prorroga la licencia sin esa exposición retroactiva.

Virginia Board for Contractors, Individual License and Certification Regulations, 18 VAC 50-30-140(B)
La tierra como vía de paso de la corriente de fallo a tierravsTrayectoria efectiva de la corriente de fallo a tierra

El NEC prohíbe expresamente utilizar la tierra como vía efectiva para la corriente de fallo a tierra; una vía efectiva debe ser un circuito de baja impedancia capaz de conducir de forma segura la corriente máxima de fallo a tierra para facilitar el funcionamiento de los dispositivos de protección contra sobrecorriente.

NEC 2020, Section 250.4(A)(5)
Conductor de tierra con sección ≤6 AWGvsIdentificación del conductor de tierra >6 AWG

Los conductores de 6 AWG o de sección inferior deben identificarse mediante un revestimiento exterior continuo de color blanco o gris (o tres franjas blancas o grises), mientras que para los conductores de mayor sección se permiten otros métodos de identificación según la norma NEC 200.6.

NEC 2020, Section 200.6(A)
Disyuntores con marcado SWD/HIDvsDisyuntores estándar

Los disyuntores utilizados como interruptores en circuitos de iluminación fluorescente de 120 o 277 voltios deben estar homologados y llevar la marca SWD o HID; no se permite el uso de disyuntores estándar que no lleven esta marca para dicha aplicación de conmutación.

NEC 240.83(D)
Cable tipo SE (para uso en interiores)vsCable tipo NM

El cable de tipo SE utilizado para circuitos derivados o ramales interiores debe cumplir los requisitos de instalación del artículo 334 (cable NM), pero queda expresamente excluida la limitación de la capacidad de carga eléctrica prevista en el apartado 334.80.

NEC 2020, Section 338.10(B)(4)(a)
Exención de los requisitos del NEC por parte de la autoridad competente (AHJ)vsAplicación de la normativa NEC estándar

La autoridad competente (AHJ) podrá eximir del cumplimiento de requisitos específicos del NEC y autorizar métodos alternativos únicamente cuando se garantice que se alcanzan objetivos de seguridad equivalentes y se presente documentación técnica que demuestre dicha equivalencia; en caso contrario, se aplicarán los requisitos estándar del Código.

NEC 2020, Informative Annex H, Section 80.13(15)

Términos Clave

Restablecimiento de la licencia — Licencia continua (Virginia) Virginia Board for Contractors, Individual License and Certification Regulations, 18 VAC 50-30-140(B)
De conformidad con el artículo 18 VAC 50-30-140(B), se considera que un profesional regulado que restablece una licencia de Virginia caducada ha mantenido su licencia de forma ininterrumpida y sigue estando sujeto a la autoridad disciplinaria de la junta durante todo el período de caducidad.
Actividad sin licencia tras la caducidad (Virginia) Virginia Board for Contractors, Individual License and Certification Regulations, 18 VAC 50-30-130(E)
De conformidad con el artículo 18 VAC 50-30-130(E), cualquier actividad regulada que se realice tras la caducidad de una licencia de Virginia puede constituir una actividad sin licencia, susceptible de ser objeto de acciones judiciales en virtud del Título 54.1 del Código de Virginia.
Definición de «trabajos eléctricos» (Virginia) Virginia Board for Contractors, Individual License and Certification Regulations, 18 VAC 50-30-10(D)
Según el artículo 18 VAC 50-30-10(D), los trabajos eléctricos incluyen la planificación, el trazado, la instalación de conductos, el mantenimiento y la reparación de sistemas eléctricos, así como la supervisión de los sistemas instalados para detectar posibles riesgos; no incluyen la instalación de tuberías de gas.
Actos prohibidos: cesión de la licencia (Virginia) Virginia Board for Contractors, Individual License and Certification Regulations, 18 VAC 50-30-190
De conformidad con el artículo 8 de la norma 18 VAC 50-30-190, permitir que una persona sin licencia ni certificación utilice la licencia o certificación de Virginia de otra persona constituye un acto prohibido que puede dar lugar a medidas disciplinarias contra el titular de la licencia.
Formación continua — Técnico electricista (Virginia) Virginia Board for Contractors, Individual License and Certification Regulations, Page 21
De conformidad con el artículo 50-30-120(C) del Reglamento 18 VAC, las personas titulares de una licencia de artesano de Virginia con la especialidad de electricidad deben completar 3 horas de formación continua homologada relacionada con los cambios aplicables en la normativa de edificación como condición para la renovación o la reactivación de dicha licencia.
Tasa de restablecimiento de la licencia de comerciante (Virginia) Virginia Board for Contractors, Individual License and Certification Regulations, Page 23
De conformidad con el artículo 50-30-130(A) y (B) del Código Administrativo de Virginia (VAC), si la licencia de profesional de Virginia no se renueva en un plazo de 30 días a partir de su fecha de caducidad, se deberá abonar una tasa de restablecimiento no reembolsable de 210,00 dólares (que incluye la tasa de renovación).
Responsabilidad exclusiva del contratista respecto a los trabajadores sin acreditación (Virginia) Virginia Board for Contractors, Individual License and Certification Regulations, Code of Virginia § 54.1-1115.01
De conformidad con el artículo 54.1-1115.01 del Código de Virginia, un contratista que contrate o trabaje con una persona que carezca de la acreditación exigida por la Junta será el único responsable de cualquier multa o sanción económica que se derive de ello.
Inhabilitación por suspensión o revocación del permiso de conducir (Virginia) Virginia Board for Contractors, Individual License and Certification Regulations, § 54.1-1110
De conformidad con el artículo 54.1-1110, cualquier persona cuya licencia de contratista de Virginia haya sido suspendida o revocada no podrá obtener una licencia bajo ninguna circunstancia ni bajo ningún nombre, salvo en los casos previstos en el reglamento de la Junta.
Capacidad de carga NEC 2020, Article 100 (Definitions, Part I)
Según el artículo 100 del NEC, la capacidad de conducción de corriente es la corriente máxima, expresada en amperios, que un conductor puede transportar de forma continua en las condiciones de uso previstas sin superar su temperatura nominal.
Punto de servicio NEC 2020, Article 100 (Definitions, Part I — Service Point)
Según el artículo 100 del NEC, el punto de servicio es el punto de conexión entre las instalaciones de la empresa de suministro y el cableado del inmueble, y es la empresa de suministro la que determina su ubicación.
Autoridad competente (AHJ) NEC 2020, Section 90.4
Según la norma NEC 90.4, la autoridad competente (AHJ) es la entidad encargada de interpretar el Código, aprobar equipos y materiales, y conceder permisos especiales.
Circuito derivado multifilar: requisito de uso del mismo cuadro eléctrico NEC 2020, Section 210.4(A)
De acuerdo con la norma NEC 210.4(A), todos los conductores sin conexión a tierra de un circuito derivado multiconductor deben tener su origen en el mismo cuadro eléctrico o en un equipo de distribución similar.
Longitud libre del conductor en los puntos de salida, empalme e interruptor NEC 2020, Section 300.14
Según la norma NEC 300.14, debe dejarse al menos 6 pulgadas (150 mm) de conductor libre en cada toma de corriente, empalme y punto de conmutación, medido desde el punto en el que el conductor sale de su canalización o de la funda del cable.
Regla de terminación a 75 °C NEC 2020, Section 110.14(C)(1)(b)
De acuerdo con la norma NEC 110.14(C)(1)(b), en el caso de circuitos de más de 100 amperios, la capacidad de carga de los conductores en los puntos de conexión debe basarse en la columna de 75 °C, salvo que el equipo esté homologado e identificado para su uso con conductores de mayor capacidad nominal.
Sección mínima del conductor de cobre (cableado general) NEC 2020, Section 310.3(A)
Según la norma NEC 310.3(A), la sección mínima de los conductores de cobre con una tensión nominal de hasta 2000 voltios para el cableado general es de 14 AWG.
Objetivo de NEC NEC 2020, Section 90.1(A)
Según el artículo 90.1(A) del NEC, el objetivo del NEC es la protección práctica de las personas y los bienes frente a los riesgos derivados del uso de la electricidad, y no pretende ser una especificación de diseño ni un manual de instrucciones para personas sin formación.

Fórmulas que Debes Saber

Carga de servicio opcional para viviendas (NEC 220.82)Carga total = 100 % de los primeros 10 kVA de cargas generales + 40 % del resto de las cargas generales
Umbral del electrodo suplementarioNO es necesario utilizar un electrodo adicional si la resistencia de una sola varilla es ≤ 25 Ω; sí es necesario si es > 25 Ω
Umbral de protección de chapa de acero (cable en el armazón)Si el borde del orificio taladrado está a menos de 1-1/4 pulgadas (32 mm) del borde de madera más cercano → instale una placa de acero de un grosor ≥ 1/16 pulgadas (1,6 mm)
Número máximo de desconexiones por suministro (estructura independiente)Desconexiones por suministro: ≤ 6 interruptores o 6 disyuntores agrupados en una misma ubicación
Servicio adicional permitido (umbral de capacidad de corriente)Se permite un servicio adicional si la capacidad es superior a 2000 A con una tensión de alimentación ≤ 1000 V
Requisitos de experiencia para el examen de oficial (Virginia)Con 240 horas de formación reglada → 4 años de experiencia; Sin formación reglada → 8 años de experiencia