Exam Cheat Sheet · Quick Reference
Arkansas Masonry - Commercial Exam
Arkansas · PSI Services Contractor
Arkansas State Portion 30 questions
Key Distinctions
A cavity wall has two walls separated by a continuous air space at least 2 inches wide; if the cavity is less than 2 inches the wall is classified as a veneered wall.
Modern Masonry (9th ed.), Chapter 13 — Laying Block, Section 13.2.3Only mortar stiffened by evaporation may be retempered with water; mortar stiffened by hydration (chemical setting) must be discarded.
Modern Masonry (9th ed.), Chapter 10, Page 190Masonry mortar not used within 2 1/2 hours should be discarded, while glass masonry mortar not used within 1 1/2 hours after remixing should be discarded (and not retempered after initial set).
Modern Masonry (9th ed.), Page 222Grade SW is highly resistant to frost action for exposure to freezing weather (foundation courses, retaining walls); Grade MW is for moderate exposure below freezing where brick is not likely to be permeated with water, and Grade NW is for interior backup masonry.
Modern Masonry (9th ed.), Page 116Type S (medium-high strength, maximum flexural/tensile bond) is required for cavity walls where wind velocities may exceed 80 mph and is recommended for reinforced masonry; for lesser winds either Type S or Type N may be used, Type N being a general-purpose above-grade mortar.
Modern Masonry (9th ed.), Chapter 10 — Mortar and Grout, Section 10.5.8 — Cavity WallsType M is used for masonry below grade and in contact with earth (foundations, retaining walls, manholes), while Type N is a general-purpose above-grade mortar.
Modern Masonry (9th ed.), Chapter 10, Pages 191-192Ladder-type reinforcement is recommended to tie the wythes of a brick and block cavity wall because it allows in-plane movement; truss-type should not be used for that purpose.
Modern Masonry (9th ed.), Page 245Open (mortar-removed) weep holes are spaced no more than 24 inches O.C., while wicking-material weep holes are spaced at a maximum of 16 inches O.C.
Modern Masonry (9th ed.), Page 335Wall anchor construction is limited to a 100 sq ft panel (max 10 ft high, 10 ft wide), chase construction allows up to 144 sq ft (max 20 ft high, 25 ft wide), and panel/curtain wall sections may be erected up to 250 sq ft if properly braced to limit movement and settlement.
Modern Masonry (9th ed.), Chapter 8 — Concrete Masonry Units, Section 8.2.5Common/American bond is a running-bond variation with full-length header courses generally every fifth to seventh course; Flemish alternates headers and stretchers in every course, English uses alternating full courses of headers and stretchers, and stack bond is purely a pattern bond with no overlapping.
Modern Masonry (9th ed.), Pages 129-130Per 2015 IBC Chapter 2, a 'mark' gives the manufacturer's name and the product function; a 'label' also carries performance characteristics and the identification of an approved agency, and a 'manufacturer's designation' indicates compliance with a specified standard or set of rules.
IBC 2015 Chapter 2 — Definitions of 'Mark,' 'Label' and 'Manufacturer's Designation'The IRC requires an 8-inch minimum nominal thickness for loadbearing masonry over one story, but permits a nominal 6-inch wall for a single-story home or garage where wall height does not exceed 9 feet and gable height does not exceed 15 feet.
Modern Masonry (9th ed.), Page 248Per IRC R404.1.1.6, concrete and masonry foundation walls shall extend above finished grade a minimum of 4 inches where masonry veneer is used and a minimum of 6 inches elsewhere.
Modern Masonry (9th ed.), Page 313Concrete that dries out and stiffens before initial set may be remixed without adding water; water cannot be added to restore workability because it reduces concrete quality.
Modern Masonry (9th ed.), Page 393Key Terms
Formulas to Know
Height shall not exceed 3/4 × (wall thickness)²; worked example: 8" wall → 3/4 × 8² = 3/4 × 64 = 48 inchesBase width ≥ 1/2 to 3/4 of the wall height (shown on drawings as 0.7H)Never greater than 1/5 the thickness of a finished wall section, 1/3 the thickness of a slab, or 3/4 the width of the narrowest space the concrete must pass through during placingDepth ≤ 1/3 of the wall thicknessNet cross-sectional area in every plane parallel to the bearing surface ≥ 75% of gross cross-sectional area in the same plane (cores less than 25%)Not less than 4% headers in the wall surface; distance between nearest headers shall not exceed 24 inches vertically or horizontallyTies 3/16" diameter or #9 gauge wire, placed one in every 4 1/2 sq ft of wall space when the cavity is no more than 4"Minimum 1/2 cubic foot of grout sampled from material being placed; one sample = three 3 1/2" × 3 1/2" × 7" specimens per ASTM C1019; sample for each 5,000 sq ft of masonry or whenever mix proportions, materials or mixing method changeAt least equal to the specified compressive strength of masonry, but not less than 2000 psi (13.8 MPa) per ASTM C1019Minimum total air content 5%; 2% or less gains no benefit and over 7% can reduce finished concrete strength