Arkansas · PSI

Arkansas Masonry - Commercial Exam Practice Exam

30 questions 75 minutes 70% to pass 8 topics 2:30 per question Open book 130 questions in pool
Free Cheat Sheet Official Bulletin
Free

Free Practice Exam

$0

Test your knowledge with 10 questions from our pool of 20 free questions.

  • 10 questions per attempt
  • 30 minute time limit
  • Unlimited attempts
  • A new mix each time
  • Instant results
No account required.
Full Exam

Full Practice Exam

$9.95

Complete exam simulation matching the real PSI test format.

  • 30 questions (same as real exam)
  • 75 minute time limit
  • 8 topic areas covered
  • 130 questions in pool
  • Detailed explanations
Price per attempt. Never the same exam twice: each attempt draws a fresh set of questions.
Not sure which exam you need? Text us: (813) 582-5360
Texts preferred · 9am–9pm Central
Want a guided study plan? Study Course: topic briefs, 8 topic quizzes and this full exam, plus the Business and Law exam. $59.95/month.
See the study course

Arkansas Masonry - Commercial Practice Exam Guide

Built from the official PSI exam bulletin. View the bulletin

What's on the exam

Questions per topic, out of 30
Unit Masonry10
Mortar and Grout7
Accessories4
Estimating and Plan Reading2
Tools2
Restoration and Cleaning2
OSHA Safety2
Stone1

This practice exam follows the official content outline for the Arkansas Masonry - Commercial exam: Estimating and Plan Reading, Unit Masonry, Mortar and Grout, Accessories, Stone, Tools, Restoration and Cleaning, OSHA Safety.

  • Free practice exam: 10 questions per attempt, retake as often as you like.
  • Full practice exam: 30 questions on a 75 minutes clock, a new draw from our bank every attempt.

8 topics

Estimating and Plan Reading 2 items

Unit Masonry 10 items

Mortar and Grout 7 items

Accessories 4 items

Our study plan for this topic: Wall ties: types and installation requirements (rectangular, Z, and corrugated ties); Adjustable ties and their applications in cavity and veneer wall construction; Joint reinforcement types (ladder, truss, and tab styles) and placement in mortar beds; Reinforcing bars and rods: sizes, placement, and corrosion protection; Anchor bolts and strap anchors: types and installation in masonry construction; Hardware cloth (mesh wall ties) for bonding intersecting masonry walls; Corrosion protection requirements for masonry metal accessories; Wall tie installation requirements per IRC (embedment depth, mortar coverage, spacing).

Stone 1 item

Tools 2 items

Restoration and Cleaning 2 items

OSHA Safety 2 items

3 questions

Sample 1 — Unit Masonry

Question: You are a remodeling carpenter planning to install a glass block panel using chase construction in a client's living room. The homeowner wants the panel as large as possible. What is the maximum allowable panel area for this type of installation?

  • A. 200 sq ft
  • B. 100 sq ft
  • C. 250 sq ft
  • D. 144 sq ft

Correct Answer: D

For glass block panels using chase construction (a reinforced masonry frame around the panel), the maximum panel area is 144 sq ft, with a maximum height of 20 feet and a maximum width of 25 feet. Wall anchor construction is limited to 100 sq ft, and panel/curtain wall sections may go up to 250 sq ft if properly braced.

Reference: Modern Masonry (9th ed.), Chapter 8 — Concrete Masonry Units, Section 8.2.5

Sample 2 — Mortar and Grout

Question: You are a masonry contractor selecting mortar for a project. Which mortar property is stated to be MORE important than compressive strength when selecting mortar?

  • A. Air content
  • B. Water retentivity
  • C. Elasticity
  • D. Durability

Correct Answer: B

Per Masonry Textbook Chapter 10, Section 10.1, because the compressive strength of masonry mortar is less important than bond strength, workability, and water retentivity, the latter properties should be given principal consideration in mortar selection. Water retentivity is one of these key properties.

Reference: Modern Masonry (9th ed.), Chapter 10 — Mortar and Grout, Section 10.1

Sample 3 — Accessories

Question: Which type of horizontal joint reinforcement is recommended when block cores or cells will receive reinforcing bars and grout?

  • A. Truss-type reinforcement
  • B. Corrugated tie reinforcement
  • C. Ladder-type reinforcement
  • D. Tab-type reinforcement

Correct Answer: C

Ladder-type reinforcement is recommended when block cores or cells are to receive reinforcing bars and grout, because the diagonal wires in truss-type reinforcement may interfere with the placement of bars in the cores and filling them with grout.

Reference: Modern Masonry (9th ed.), Chapter 11 — Anchors, Ties, and Reinforcement, Section 11.1 — Horizontal Continuous Joint Reinforcement Code Note

  • Your results break the score down by outline topic.
  • The real exam's passing score: 21 correct answers out of 30 scored questions.
  • Keep practicing until you pass consistently, not just once.

  • Answer what you know first and bookmark the rest. Our practice exams let you bookmark and come back.
  • Work your bookmarks on the second pass.
  • Real exam pace: about 2 minutes 30 seconds per question.
  • After each attempt, look up every miss in your book.

Questions 30 questions
Time limit 75 minutes
Passing score 21 correct answers out of 30 scored questions
Books in the exam room Open book

Source: Arkansas Contractors Licensing Board - Masonry Commercial, 2/6/2020. Check the bulletin before test day: fees and rules can change.

Reference books

3 books on the bulletin
As an Amazon Associate we earn from qualifying purchases.
10 free questions30 min · no account