Exam Cheat Sheet · Quick Reference
Arkansas Masonry - Residential Exam
Arkansas · PSI Services Contractor
Arkansas State Portion 30 questions
Key Distinctions
A cavity wall has two wythes separated by a continuous air space at least 2 inches wide; if the cavity is less than 2 inches the wall is classified as a veneered wall.
Modern Masonry (9th ed.), Chapter 13 — Laying Block, Section 13.2.3Type S (medium-high strength, best bond/lateral and flexural strength) is required for cavity walls where wind velocities may exceed 80 mph and is recommended for reinforced masonry, while for lesser winds either Type S or Type N may be used and Type N is the general-purpose above-grade mortar.
Modern Masonry (9th ed.), Chapter 10 — Mortar and Grout, Section 10.5.8 — Cavity WallsType M is used for masonry below grade and in contact with earth (foundations, retaining walls, manholes), while Type N is a general-purpose above-grade mortar.
Modern Masonry (9th ed.), Chapter 10, Pages 191-192Grade SW is highly resistant to frost action for bricks exposed to freezing weather (foundation courses, retaining walls); Grade MW is for moderate exposure to below-freezing temperatures where the brick is not likely to be permeated with water; Grade NW is for backup on interior masonry.
Modern Masonry (9th ed.), Page 116Mortar stiffened by evaporation may be retempered with water, but mortar stiffened by hydration (chemical setting) must be discarded and not retempered.
Modern Masonry (9th ed.), Chapter 10, Page 190Mortar not used within 2 1/2 hours should be discarded in residential masonry work, while mortar for glass masonry not used within 1 1/2 hours after remixing must be discarded.
Modern Masonry (9th ed.), Page 222Open head-joint weep holes with mortar completely removed should be spaced no more than 24 inches O.C., while wicking-material weep holes are spaced at a maximum of 16 inches O.C.
Modern Masonry (9th ed.), Page 335Wall anchor construction is limited to a 100 sq ft panel (max 10 ft high, 10 ft wide), chase construction allows up to 144 sq ft (max 20 ft high, 25 ft wide), and panel/curtain wall sections may be erected up to 250 sq ft if properly braced to limit movement and settlement.
Modern Masonry (9th ed.), Chapter 8 — Concrete Masonry Units, Section 8.2.5Ladder-type reinforcement is recommended to tie the wythes of a brick and block cavity wall because it allows in-plane movement between wythes; truss-type should NOT be used for that purpose.
Modern Masonry (9th ed.), Page 245Common/American bond is a running-bond variation with full-length header courses at regular intervals (generally every fifth to seventh course) for structural bonding, while Flemish alternates headers and stretchers in every course, English uses alternating full courses of headers and stretchers, and stack bond is purely a pattern bond with no overlapping.
Modern Masonry (9th ed.), Pages 129-130IRC R404.1.1.6 requires concrete and masonry foundation walls to extend a minimum of 4 inches above finished grade where masonry veneer is used, and a minimum of 6 inches elsewhere.
Modern Masonry (9th ed.), Page 313IRC requires an 8-inch minimum nominal wall thickness for loadbearing masonry structures over one story, but permits a nominal 6-inch wall for a single-story home or garage where wall height does not exceed 9 feet and gable height does not exceed 15 feet.
Modern Masonry (9th ed.), Page 248Concrete that dries out and stiffens before initial set may be remixed without adding water (retempering with water is not allowed), whereas mortar stiffened only by evaporation may be retempered with water.
Modern Masonry (9th ed.), Page 393Key Terms
Formulas to Know
Height ≤ 3/4 × (wall thickness)²; worked example: 8-inch wall → 3/4 × 8² = 3/4 × 64 = 48 inchesBase width ≥ 1/2 to 3/4 of the wall height (shown on drawings as 0.7H)Never greater than 1/5 the thickness of a finished wall section, 1/3 the thickness of a slab, or 3/4 the width of the narrowest space the concrete must pass through during placingNet cross-sectional area in every plane parallel to the bearing surface ≥ 75% of gross cross-sectional area in the same plane (cores < 25%)Depth ≤ 1/3 of the wall thicknessNot less than 4% headers in the wall surface; distance between nearest headers shall not exceed 24 inches vertically or horizontallyTies 3/16 inch diameter or #9 gauge wire, placed one in every 4 1/2 sq ft of wall space when the cavity is no more than 4 inches (Z tie is most common)Sample a minimum of 1/2 cubic foot of grout from material being placed; one sample = three 3 1/2" × 3 1/2" × 7" specimens; take a sample for each 5,000 sq ft of masonry or whenever mix proportions, materials, or mixing method change; grout compressive strength at least equal to specified f'm but not less than 2000 psi (13.8 MPa)Minimum total air content 5%; 2% or less does not gain the admixture's benefit and over 7% can reduce finished concrete strengthPermitted for steel, ferrous or copper pipes, tubes or conduits where nominal diameter of the penetrating item is not more than 6 inches and the opening area does not exceed 144 square inches, with concrete/grout/mortar placed full thickness