Verified, not estimated. Every figure below is drawn from the official exam structure we maintain — question counts, passing standard and topic weighting. Practice questions are grounded in the source law with statute citations. We omit any figure we can't verify rather than guess at it.
Total questions
115
Passing score
72%
Exam time
210 min
Administered by
PSI Services Contractor
Format
Closed-book

California State Portion 115 questions

Planning and Estimating 17 Q · 15%
Scope of work and code complianceDesign and construction error identificationShop drawings, plans, and specificationsField inspection performanceCoordination of projectCost estimation for materials, equipment, and laborPermit application requirements and construction document submittalsBuilding height, area, and type of construction limitationsOccupancy classification determination and mixed-occupancy planningFire protection system requirements by occupancy and building sizeGreen building and CALGreen mandatory measures in project planningEnergy code compliance planning for residential and nonresidential buildings +2 more
Framing and Structural Components 23 Q · 20%
Subfloor and wall framingRoof framingSeismic hardware requirements and installationSiding and stuccoDecks and stairsLumber grading, species, and sizing for framingEngineered wood products (I-joists, LVL, glulam, CLT, structural composite lumber)Wood structural panel sheathing (plywood and OSB) grades, span ratings, and fasteningStud sizing, spacing, and height limitations for bearing and nonbearing wallsHeaders, girders, and beam spans for openings in bearing wallsDrilling, notching, and top plate modifications for mechanical penetrationsPreservative and fire-retardant treatment of wood +1 more
Core Trades 35 Q · 30%
PlumbingElectricalHVACConcreteEarthwork and surveyingInsulation, acoustical, and weatherproofingRoofingWater heater installation, venting, and safety devicesDrainage, waste, and vent (DWV) systemsTraps, interceptors, and backflow preventionElectrical service, distribution, and load calculationsGrounding, bonding, and overcurrent protection +2 more
Finish Trades 23 Q · 20%
Painting, staining, coating, and interior wall coveringTile and stoneFloor coveringCabinetry and millworkPlaster, drywall, and ceilingsWindows, skylights, and doorsLandscapingInterior finish flame spread and smoke development classifications (CBC Chapter 8)Safety glazing requirements and hazardous location identification (CBC Chapter 24)Gypsum board and gypsum panel product types, installation, and fastening requirementsAcoustical ceiling systems and suspended ceiling constructionDoor hardware: locks, hinges, closers, and accessibility requirements +2 more
Safety 17 Q · 15%
Personnel safetyTransportation and traffic controlEnvironmental safetyFall protection and guardrail systemsExcavation and trenching safetyScaffolding requirements and useHazard communication and Safety Data Sheets (SDS)Fire protection and prevention during constructionConfined space entry proceduresInjury and Illness Prevention Program (IIPP)Lockout/tagout and hazardous energy control

Key Distinctions

Slope (rise per run)vsPitch (rise to span)

Slope is the rise over the run (6" in 12" = 1/2), while pitch is the rise divided by the span, which is twice the run (6/24 = 1/4).

Modern Carpentry, 14th Ed., Ch. 12 (Roof Framing), Section 12.3 — Slope and Pitch
Nails in side grainvsNails in end grain

Nails driven perpendicular to the fibers (side grain) develop allowable lateral (shear) loads 50% higher than the same nails driven into end grain, and an end-nailed joint should never be loaded in direct withdrawal.

Olin's Construction, 9th Ed., Section 6.6.2 (Nailing Practices)
Builder's levelvsTransit

The builder's level telescope is fixed in the horizontal plane, while the transit telescope can be pivoted up and down 45° in each direction so vertical angles can be measured — preferred on sloping sites with stakes at varying heights.

Modern Carpentry, 14th Edition, Chapter 8, Leveling Instruments
Plain groutvsSanded grout

Plain grout (cement with additives for smooth consistency) is used for ceramic floor tile joints less than 1/16" wide; where joints exceed 1/16", sand is added to form sanded grout, which resists shrinkage in the wider joint.

Modern Carpentry, 14th Ed., Ch. 20, Installing Tile—Grout
Honed-finish stone tilevsTextured-finish stone tile

Honed tiles may be laid with narrow 1/8 in. joints and grouted with neat cement, while the irregular surface of textured tiles requires joints of at least 1/4 in., grouted 1 part cement to 3 parts sand.

Olin's Construction, 9th Ed., Section 9.9.2.6 (Installation)
ANSI A108.1vsANSI A108.4

ANSI A108.1 is the Thick Bed Mortar Method (full portland cement mortar setting bed) and ANSI A108.4 is the Thin Bed Mortar Method (thin-set).

Olin's Construction, 9th Ed., Section 9.9.2.3 (Applicable Standards)
Thermoplastic single-ply membrane (TPO, PVC)vsThermosetting/elastomeric membrane (EPDM, PIB, CSPE)

Thermoplastics soften with heat so field seams can be heat or solvent welded as strong as the sheet, whereas thermosetting membranes cannot be softened by heat and are seamed with liquid adhesives or pressure-sensitive tapes.

Fundamentals of Building Construction: Materials and Methods, 6th Edition, Chapter 16 — Single-Ply Roof Membranes
Blast furnace slag (slag cement)vsPozzolans (fly ash, silica fume, high-reactivity metakaolin)

Blast furnace slag is a hydraulic cement that reacts directly with water like portland cement, while pozzolans must react with the calcium hydroxide present in the wet concrete to form cementing compounds.

Fundamentals of Building Construction: Materials and Methods, 6th Edition, Chapter 13 — Supplementary Cementitious Materials
LVL veneer orientationvsPlywood veneer orientation

All LVL veneers run lengthwise with grain in the same direction (parallel lamination for beam, header and truss loads), while plywood places each veneer at 90° to the previous one.

Modern Carpentry, 14th Ed., Ch. 3 (Building Materials), Section 3.10 — Laminated-Veneer Lumber
Bid bond (bid security)vsPerformance bond and payment bond

Bid security guarantees the bidder will sign an agreement based on the submitted bid or forfeit the bond amount; the performance bond secures completion of the signed contract and the payment bond secures payment of the constructor's related debts.

Olin's Construction: Principles, Materials, and Methods, 9th Ed., Section 1.7.2.1
GFCI devicevsCircuit breaker / fuse

A GFCI compares hot-leg and neutral current and trips on an imbalance as small as 4 milliamps (as fast as 1/30 second) to protect against electric shock, while breakers and fuses protect against fires.

Modern Carpentry, 14th Edition, Section 31.2, Electrical System Components
Drum and bottle trapsvs"S" traps, bell traps, crown-vented traps

Under CPC 1004.1 drum and bottle traps are not outright prohibited but shall be installed only for special conditions, while "S" traps, bell traps and crown-vented traps are prohibited.

2025 California Plumbing Code, Section 1004.1

Key Terms

Accessory occupancy (CBC 508.2.3) California Building Code 2025, Section 508.2.3
Aggregate accessory occupancies shall not occupy more than 10 percent of the floor area of the story in which they are located and shall not exceed the nonsprinklered tabular values of Table 506.2 for each such accessory occupancy, with allowable area and height still based on the main occupancy.
Design occupant load with multiple functions (CBC 1004.3) California Building Code 2025, Section 1004.3
Where an area contains multiple functions having different occupant load factors, the design occupant load is based on the floor area of each function calculated independently — blending, averaging or a single blanket factor is not permitted.
Expansive soil (CRC R403.1.8.1) California Residential Code 2025, Section R403.1.8.1
Soil classified as expansive, one criterion being a plasticity index of 15 or greater determined per ASTM D4318 (other listed criteria: more than 10 percent of particles passing a No. 200 sieve, more than 10 percent of particles smaller than 5 micrometers, and an expansion index greater than 20 per ASTM D4829).
Attic net free ventilating area (CRC R806.2) CRC R806.2
Baseline minimum net free ventilating area is 1/150 of the vented space; the reduction to 1/300 is permitted only where a Class I or II vapor retarder is installed on the warm-in-winter side of the ceiling in Climate Zones 6, 7 and 8 and not less than 40 percent and not more than 50 percent of the required area is in upper ventilators located not more than 3 feet below the ridge, with the balance in the bottom portion.
Vinyl exterior soffit panels, high wind (CRC R704.3.1) California Residential Code 2025, Section R704.3.1
Where the design wind pressure exceeds 30 psf, intermediate nailing strips are required where the unsupported span of vinyl soffit panels is greater than 12 inches; the 16-inch limit of R704.2.1 applies only at design wind pressures of 30 psf or less.
Fixture trap liquid seal (CPC 1005.1) 2025 California Plumbing Code, Section 1005.1
Each fixture trap shall have a liquid seal of not less than 2 inches and not more than 4 inches, except where a deeper seal is found necessary by the Authority Having Jurisdiction.
Tailpiece (CPC 1001.2) 2025 California Plumbing Code, Section 1001.2
The vertical distance between a fixture outlet and the trap weir shall be as short as practicable and in no case may the tailpiece exceed 24 inches.
Steel nail plate protection (CPC 312.9) 2025 California Plumbing Code, Section 312.9
Plastic or copper piping penetrating framing to within 1 inch of the exposed framing must be protected by steel nail plates not less than No. 18 gauge (0.0478 in.) extending along the framing member not less than 1-1/2 inches beyond the outside diameter of the pipe or tubing.
Booster pump low-pressure cutoff (CPC 609.9) California Plumbing Code 2025, Section 609.9
Where a booster pump (excluding a fire pump) is connected to a building supply or underground water pipe, a low-pressure cutoff switch shall be installed on the inlet side not more than 5 feet from the inlet and shall be set for not less than 10 psi.
Water heater drainage pan (CPC 507.5) 2025 California Plumbing Code, Section 507.5
A watertight corrosion-resistant pan not less than 1-1/2 inches deep, drained by not less than a 3/4 inch drain to an approved readily visible termination with piping rated for the heater's temperature; discharge from a relief valve into the pan is expressly prohibited.
Water heater seismic strapping (CPC 507.2) 2025 California Plumbing Code, Section 507.2
Water heaters shall be anchored or strapped against horizontal displacement from earthquake motion at points within the upper one-third and lower one-third of the tank's vertical dimension, with not less than 4 inches maintained above the controls at the lower point.
Ignition source elevation in residential garages (CPC 507.13) 2025 California Plumbing Code, Section 507.13
Appliances in residential garages and adjacent spaces opening to the garage that are not part of the living space shall have heating elements, switches, burners and burner-ignition devices located not less than 18 inches above the floor; the only exception is listed FVIR appliances.
Assured equipment grounding conductor program (Title 8 §2405.4(d)) Cal/OSHA Title 8, §2405.4(d)(5)
A construction-site alternative to GFCIs requiring visual inspection before each day's use (except cord sets and receptacles that are fixed and not exposed to damage), continuity and terminal testing at intervals not exceeding 3 months (6 months for cord sets and receptacles that are fixed and not exposed to damage), plus testing before first use of new equipment, after repairs and after any incident suspected of causing damage, and identification by log, color code or other means indicating the last test date or interval tested.
Respirable crystalline silica PEL (Title 8 §1532.3(d)(1)) Cal/OSHA Title 8 Construction Safety Orders, §1532.3(d)(1)
Under the alternative exposure control method, no employee may be exposed above 50 micrograms per cubic meter as an 8-hour TWA; 25 µg/m³ is the action level, not the PEL.
Chromium (VI) PEL (Title 8 §1532.2(c)) Cal/OSHA Title 8 Construction Safety Orders, §1532.2(c)
No employee shall be exposed to an airborne concentration of chromium (VI) in excess of 5 micrograms per cubic meter as an 8-hour TWA; 2.5 µg/m³ is the action level.
Simple sloping option for excavations (Title 8 §1541.1(b)(1)(A), Option 1) Cal/OSHA Title 8 Construction Safety Orders, §1541.1(b)(1)(A)
The option requiring no soil classification, appendices or engineer permits excavation sides sloped no steeper than 1 1/2 horizontal to 1 vertical (34 degrees from horizontal), the Type C soil slope.

Formulas to Know

Roof pitch from rise and runPitch = rise ÷ span, where span = 2 × run; example: 6" rise per 12" run → 6/24 = 1/4 pitch (rise/run of 1/2 is the slope, not the pitch)
Board feet of lumber (nominal sizes)Bd ft = (No. pcs × T × W × L) ÷ 12 using nominal thickness/width in inches and length in feet; example: (15 × 2 × 10 × 12) ÷ 12 = 300 bd ft
Concrete for a slab, with waste allowanceCu yd = (length × width × thickness in feet) ÷ 27, then × waste factor; example: 27' × 30' = 810 sq ft × 1/3 ft (4") = 270 cu ft ÷ 27 = 10 cu yd × 1.10 = 11 cu yd
Area of a circle / volume of cylindrical piersArea = π × radius² (use radius, not diameter); cylinder volume = area of face × height, then ÷ 27 for cubic yards; examples: 3.1416 × 6' × 6' = 113.1 sq ft; 3.1416 × 0.5' × 0.5' × 4' = 3.14 cu ft each, ×10 = 31.4 cu ft ÷ 27 ≈ 1.2 cu yd
U-value of an assembly from layer R-valuesU = 1 ÷ total R (sum of all layers and air films); example: total R 14.43 → U = 0.07
Grade difference using multiple instrument setupsDifference in grade = (sum of plus/backsight readings) − (sum of minus/foresight readings); example: (5'-8" + 6'-0") − (2'-6" + 2'-4") = 11'-8" − 4'-10" = 6'-10"
Rafter quantity for a plain gable roofMultiply building length by the spacing factor (3/4 for 16" OC, 3/5 for 20" OC, 1/2 for 24" OC), round up and add one for one side, then double for both sides; example at 16" OC: 36 × 3/4 = 27 → 28 → 28 × 2 = 56 rafters
Footing thickness under columns and postsThickness ≈ 1 1/2 × distance from face of column to edge of footing; example: (30" − 6") ÷ 2 = 12"; 1.5 × 12" = 18"
Maximum channelizing device spacing in work zonesSpacing in feet should not exceed 1.0 × posted speed in mph for taper channelization and 2.0 × posted speed for tangent channelization; example at 40 mph: 40 ft taper, 80 ft tangent
Squaring a rectangular layout (diagonal check)a² + b² = c²; example: 24² + 32² = 1,600, √1,600 = 40'-0" diagonal (a 3-4-5 multiple)