Exam Cheat Sheet · Quick Reference

California C-43 Sheet Metal Contractor Exam

California  ·  PSI Services Contractor

Verified, not estimated. Every figure below is drawn from the official exam structure we maintain — question counts, passing standard and topic weighting. Practice questions are grounded in the source law with statute citations. We omit any figure we can't verify rather than guess at it.
Total questions
115
Passing score
72%
Exam time
210 min
Administered by
PSI Services Contractor
Format
Closed-book

California State Portion 115 questions

Planning and Estimating 24 Q · 21%
Reviewing project plansEvaluating job sitesDesigning sheet metal projectsCalculating costsRainfall intensity data and drainage factor tablesDownspout and scupper sizing calculationsGutter sizing methods and expansion allowancesMetal material selection and thickness/weight specifications for sheet metalGalvanic corrosion considerations in material pairingCMC code requirements for duct systems and materialsMaterial takeoff from stretch-out: sheets, coils, and lineal feet required, with waste
Fabrication 27 Q · 23%
Layout and pattern productionProcessing sheet metalWelding, soldering, and mechanical assemblyRectangular duct gauge selection and pressure classificationRound and flat oval duct gauge and seam type selectionDuct reinforcement types, spacing, and rigidity classificationTransverse joints and longitudinal seams for rectangular ductTie rod and midpanel tie rod applications for duct constructionCoping design, profiles, and joint systems
Installation 39 Q · 34%
Preparing for installationGutters, downspouts, and drainageFlashingsHoods and exhaustMetal roofs, siding, and panelingSpecialty and miscellaneous itemsDuct sealing, pressure classification, and leakage testingDuct hangers, supports, and hanger spacing requirementsFlexible duct installation requirements and length limitationsCommercial Type I and Type II hood clearances and grease duct enclosuresExhaust duct termination requirements and separation distancesBuilding expansion joint installation +2 more
Safety 25 Q · 22%
Personal safetyShop and job site safetyHoisting and rigging operationsInjury and illness prevention program (IIPP) requirementsFall protection systems and requirementsScaffolding erection, use, and inspectionLadder selection, inspection, and safe useFire protection, prevention, and flammable/combustible liquid storageWelding and cutting safety (gas, arc, and fire prevention)Hazard communication, safety data sheets, and chemical labelingLockout/tagout and hazardous energy controlPower operated presses, press brakes, shears, and metal working machine guarding +2 more

Key Distinctions

Soft soldervsHard solder (brazing compounds / silver solder)

Soft solders melt below 700°F (370°C) and are the solders used for architectural sheet metal, while hard soldering compounds melt above 1200°F (650°C) and are used for high-pressure piping rather than architectural work.

SMACNA Architectural Sheet Metal Manual (7th ed.), Appendix K, K.1 Soldering
Lapped-and-soldered seamvsLocked-and-soldered seam

A lapped-and-soldered joint requires rivets through the lap for added strength, while a locked-and-soldered joint does not require rivets.

SMACNA Architectural Sheet Metal Manual (7th ed.), Appendix K — Soldering
Rectangular duct performance test pressurevsRound and oval duct performance test pressure

In the DPTS test sequence rectangular duct is pressurized 50 percent above the target class level (safety factor 1.5) while round and oval duct is pressurized 100 percent above it (safety factor 2).

SMACNA HVAC Duct Construction Standards (4th ed.), Chapter 11, DPTS-2005 Sections 3.1 and 6.0
Roof-to-wall expansion joint covervsRoof cap-type expansion joint cover

Roof-to-wall covers carry more stress and wind uplift so the minimum recommended material is 22 ga galvanized steel (or 16 oz. copper, 24 ga stainless, 0.050 in. aluminum), versus the lighter 24 ga galvanized recommended for roof cap joints.

SMACNA Architectural Sheet Metal Manual (7th ed.), Chapter 5, Figure 5-6 Building Expansion Joints — Roof-to-Wall
Product-conveying ductvsEnvironmental air duct

Product-conveying duct conveys solid or liquid particulates, vapors, noxious and toxic gases, and air at temperatures exceeding 250°F, while environmental air duct conveys air at temperatures not exceeding 250°F (CMC 2025 §206.0).

California Mechanical Code 2025, Section 206.0, Definition of Duct, Product-Conveying
Aluminum sheet weightvsSteel sheet weight (same thickness)

Aluminum is figured at about 14.258 lb/ft² per inch of thickness versus about 41.82 lb/ft² per inch for galvanized/black iron (41.99 for 300-series stainless), roughly one-third the weight at equal thickness.

SMACNA Architectural Sheet Metal Manual (7th ed.), Appendix A, Table A-1 and Table A-5 notes
Body belt used with fall restraint or positioning device (900 lb)vsPersonal fall arrest system used with body harness (1,800 lb)

Body belts used with fall restraint systems or positioning devices must limit maximum arresting force to 900 pounds (§1670(b)(13)), while the 1,800-pound limit of §1670(b)(11)(A) applies to a personal fall arrest system used with a body harness.

Cal/OSHA Title 8 Construction Safety Orders, §1670(b)(13)
Controlled access zone control line (39 to 45 in.)vsRoofing warning line (34 to 45 in.)

Control lines for a controlled access zone must have their lowest point including sag not less than 39 inches and highest point not more than 45 inches above the working level, while the 34-to-45-inch range applies to warning lines in roofing operations under §1730.

Cal/OSHA Title 8 Construction Safety Orders, §1671.2(a)(6)(B)
Guardrail top rail force (200 lb)vsMid-rail / screen / mesh force (150 lb)

Top rails must withstand 200 pounds per §1620(c), while mid-rails, screens, mesh, intermediate vertical members, solid panels and equivalent members must withstand at least 150 pounds (666 N) applied in any downward or outward direction at any point per §1620(d).

Cal/OSHA Title 8 Construction Safety Orders, §1620(d)
HazCom label revision (6 months)vsSafety data sheet revision (3 months)

Labels must be revised within six months of becoming aware of significant new hazard information (§5194(f)(11)), while the new information must be added to the SDS within three months (§5194(g)(5)).

Cal/OSHA Title 8 General Industry and Electrical Safety Orders, §5194(f)(11) and §5194(g)(5)
High-heat procedures (95°F or above)vsHeat wave acclimatization observation

High-heat procedures apply when the temperature equals or exceeds 95°F and require pre-shift meetings, observation, and water reminders for construction, whereas a heat wave (predicted high at least 80°F and at least ten degrees above the average high of the preceding five days) requires close observation of all employees by a supervisor or designee.

Cal/OSHA Title 8 General Industry and Electrical Safety Orders, §3395(e)
Curved-surface radius limit for copper (10 ft)vsCurved-surface radius limit for prefinished metals (15 ft)

Typical curved surface radius limits are 10 ft (3.1 m) for copper versus 15 ft (4.6 m) for prefinished metals; soft metals are used where the metal must be stretched.

SMACNA Architectural Sheet Metal Manual (7th ed.), Chapter 6, Figures 6-20 and 6-22 Mansard Roofs / Domes and Conical Roofs
Ladder-jack scaffold general ladder spacing (16 ft)vsSpacing with a single dressed 2 in. x 14 in. plank platform (12 ft)

Ladders on ladder-jack scaffolds may be up to 16 feet apart center to center generally, but not more than 12 feet apart where the platform is a single dressed 2-inch by 14-inch plank (§1648(b)).

Cal/OSHA Title 8 Construction Safety Orders, §1648(b)

Key Terms

Combustible liquid (HazCom) Cal/OSHA Title 8 General Industry and Electrical Safety Orders, §5194(c), definition of Combustible liquid
Any liquid having a flashpoint greater than 199.4°F (93°C), formerly designated Class IIIB; liquids with lower flashpoints fall into the flammable liquid hazard categories.
Product-conveying duct California Mechanical Code 2025, Section 206.0, Definition of Duct, Product-Conveying
Ducting used to convey solid or liquid particulates, vapors, noxious and toxic gases, and air at temperatures exceeding 250°F.
Portable cooling unit California Mechanical Code 2025, Section 218.0, Definition of Portable Cooling Unit
A self-contained refrigerating system not over 3 horsepower (2.2 kW) rating that has been factory assembled and tested and is installed without supply-air ducts and without connecting any refrigerant-containing parts.
Heat wave Cal/OSHA Title 8 General Industry and Electrical Safety Orders, §3395(g)(1)
Any day in which the predicted high temperature is at least 80°F and at least ten degrees higher than the average high daily temperature of the preceding five days, during which all employees must be closely observed by a supervisor or designee.
Written certification of PPE hazard assessment Cal/OSHA Title 8, §3380(f)(2)
A document that identifies the workplace evaluated, the person certifying that the evaluation was performed, the date(s) of the hazard assessment, and identifies itself as a certification of hazard assessment; it need not list the PPE selected.
Tagout device attachment means Cal/OSHA Title 8 General Industry and Electrical Safety Orders, §3314(e)
A non-reusable, hand-attachable, self-locking and non-releasable attachment with a minimum unlocking strength of no less than 50 pounds, used where equipment cannot be locked out.
Momentary contact device Cal/OSHA Title 8 General Industry and Electrical Safety Orders, §3384(b)
The device (as defined in §3941) that is the sole exception permitting gloves to be worn at machinery where hand protection could otherwise become entangled in moving machinery or materials.
Protective footwear standard Cal/OSHA Title 8, §3385(c)
Footwear purchased after January 26, 2007 for falling-object and penetration hazards must meet ASTM F 2412-05 (test methods) and ASTM F 2413-05 (performance specification); ANSI Z41-1999 applied only to footwear purchased on or before that date.
Girth (stretch-out) SMACNA Architectural Sheet Metal Manual (7th ed.), Figure 1-1 / Table 1-5 (girth = width of unformed metal stock)
The width of the unformed flat stock needed to produce a formed profile; take-offs are based on the stretch-out, not the finished dimension.
Base box (zinc-tin alloy / terne) SMACNA Architectural Sheet Metal Manual (7th ed.), Appendix B.6 Zinc-Tin Alloy
A unit of 112 sheets measuring 20 in. by 28 in., approximately 436 ft² of sheet area, over which the 20 lb or 40 lb coating weight is distributed on both sides.
Drainage factor SMACNA Architectural Sheet Metal Manual (7th ed.), Chapter 1, Table 1-2 and Downspout Sizing Considerations
The tabulated roof area drained per square inch of downspout cross section (e.g., 160 ft²/in.²); the design roof area is divided by it to obtain required downspout area.
Head (H) for scupper sizing SMACNA Architectural Sheet Metal Manual (7th ed.), Appendix G, Scupper Sizing Procedures
The depth of water in inches measured at a point 6 ft (1.8 m) back from the scupper opening; codes typically set 1 in. as the minimum head.
Overflow scupper SMACNA Architectural Sheet Metal Manual (7th ed.), Appendix G, Scupper Sizing
A scupper serving as secondary (overflow) drainage, recommended at the rate of one scupper for each interior roof drain, although scuppers are also used as primary drains.
Conductor head SMACNA Architectural Sheet Metal Manual (7th ed.), Chapter 1, Downspout Sizing Considerations
A head set in a downspout run (required every 40 ft of vertical run to admit air and prevent a vacuum); where it has no built-in overflow, its rim is set 1 in. (25 mm) below the scupper.
No. 4 stainless steel finish SMACNA HVAC Duct Construction Standards (4th ed.), Appendix A, Stainless Steel Sheet Thickness — Finishes
The general purpose polished finish (one or both sides); No. 1 is hot-rolled, annealed and descaled, No. 6 is dull satin Tampico brushed, and No. 8 is mirror.
3003-H14 aluminum SMACNA Architectural Sheet Metal Manual (7th ed.), Appendix B.1.4 Aluminum - Types
The alloy and temper generally used for ordinary architectural sheet metal work such as roofing and flashing; 5005 is used where the sheet is anodized, 6061 is a plate/extrusion alloy, and H134 temper is for embossed sheet.
Nominal rigidity index (EI) SMACNA HVAC Duct Construction Standards (4th ed.), Appendix A, Angle, Bar and Channel Properties
The classification value for angle, bar and channel reinforcement, computed for steel as EI = 290 x 10^5 x Ix from the member's moment of inertia; the section modulus Z is used for bending stress (M/Z) instead.

Formulas to Know

Sheet weight per square foot from thicknesslb/ft² = thickness (in.) × material constant: 41.82 for galvanized and black iron, 41.99 for 300-series stainless, 41.20 for 400-series stainless, 14.258 for aluminum. Example: 0.050 in. × 41.99 = 2.10 lb/ft²; × 2,000 ft² ≈ 4,200 lb. Cost example: 0.030 in. × 41.82 = 1.25 lb/ft² × $0.90/lb ≈ $1.13/ft².
Copper and lead sheet weight from weight designationCopper: lb/ft² = oz/ft² ÷ 16 (20 oz = 1.25 lb/ft²; 2,400 ft² × 1.25 = 3,000 lb). Lead: the '4 lb' designation means 4 lb per ft² (85 ft² × 4 lb = 340 lb; × $3.10/lb = $1,054).
Duct sheet-metal surface area take-offRectangular: sq ft per linear foot = perimeter in feet = 2 × (W + H) ÷ 12; e.g., 2 × (36 + 24) = 120 in. = 10 sq ft/ft × 40 ft = 400 sq ft. Round: circumference (π × D) × length; e.g., 3.1416 × 2 ft = 6.28 sq ft/ft × 50 ft = 314 sq ft, × 1.10 for seams/waste ≈ 346 sq ft.
Total scupper discharge capacity requiredGPM = 0.0104 × IPH × roof area in ft² (constant from 7.48 gal/ft³ ÷ 12 in./ft ÷ 60 min/hr). Example: 0.0104 × 8 × 12,000 = 998 gpm.
Scupper capacity (Francis weir formula)Q = 3.33 (L − 0.2H) H^1.5, valid where the scupper opening length L is 4 to 8 times the head H.
Required downspout cross-sectional areaDesign area = roof plan area × pitch factor; divide by number of downspouts, then divide by the local drainage factor. Example: 8,000 ft² × 1.05 = 8,400; ÷ 4 = 2,100; ÷ 160 = 13.1 in.² each. Related rate: about 96.15 sq ft of surface at 1 in./hr of rainfall produces 1 gpm; downspouts under 7.00 in.² should not be used except for porches and canopies; one downspout serves a practical maximum of 50 ft of gutter (140 ft ÷ 50 = 2.8 → 3 downspouts).
Built-in gutter front-edge drop and coping slopeGutter: front high point set below the back edge 1 in. per foot of gutter width, with 1 in. absolute minimum (18 in. = 1.5 ft → 1 1/2 in.). Coping: top slopes 1/4 in. per foot of coping width toward the roof side.
Nail length from pennyweight size2d = 1 in. (25 mm); add 1/4 in. (6 mm) per size through 10d (6d = 2 in., 8d = 2 1/2 in.); sizes above 16d increase in 1/2 in. increments.
Waste-allowance piece counts (flashing take-off)Pieces = (run length in ft × 12) ÷ exposure per course, then × waste factor, round up: 85 ft × 12 ÷ 5 = 204 × 1.10 = 225 pieces; 42 ft × 12 ÷ 5 = 100.8 → 101 pieces. Stock sections = length (with waste applied once) ÷ section length, round up: 90 ÷ 10 = 9 × 1.10 = 10 sections; 42 × 1.10 = 46.2 ÷ 8 = 6 sections. Sheet stock: strips per sheet = sheet width ÷ girth, lineal ft per sheet = strips × sheet length (48 ÷ 8 = 6 × 10 ft = 60 ft; 640 × 1.10 = 704 ÷ 60 = 12 sheets).
Sealant cyclic movement capability requiredMovement % = (maximum joint width − minimum joint width) ÷ minimum joint width. Example: (7/8 − 5/8) ÷ 5/8 = 0.25 ÷ 0.625 = 40%.