Exam Cheat Sheet · Quick Reference
California C-43 Sheet Metal Contractor Exam
California · PSI Services Contractor
California State Portion 115 questions
Key Distinctions
Soft solders melt below 700°F (370°C) and are the solders used for architectural sheet metal, while hard soldering compounds melt above 1200°F (650°C) and are used for high-pressure piping rather than architectural work.
SMACNA Architectural Sheet Metal Manual (7th ed.), Appendix K, K.1 SolderingA lapped-and-soldered joint requires rivets through the lap for added strength, while a locked-and-soldered joint does not require rivets.
SMACNA Architectural Sheet Metal Manual (7th ed.), Appendix K — SolderingIn the DPTS test sequence rectangular duct is pressurized 50 percent above the target class level (safety factor 1.5) while round and oval duct is pressurized 100 percent above it (safety factor 2).
SMACNA HVAC Duct Construction Standards (4th ed.), Chapter 11, DPTS-2005 Sections 3.1 and 6.0Roof-to-wall covers carry more stress and wind uplift so the minimum recommended material is 22 ga galvanized steel (or 16 oz. copper, 24 ga stainless, 0.050 in. aluminum), versus the lighter 24 ga galvanized recommended for roof cap joints.
SMACNA Architectural Sheet Metal Manual (7th ed.), Chapter 5, Figure 5-6 Building Expansion Joints — Roof-to-WallProduct-conveying duct conveys solid or liquid particulates, vapors, noxious and toxic gases, and air at temperatures exceeding 250°F, while environmental air duct conveys air at temperatures not exceeding 250°F (CMC 2025 §206.0).
California Mechanical Code 2025, Section 206.0, Definition of Duct, Product-ConveyingAluminum is figured at about 14.258 lb/ft² per inch of thickness versus about 41.82 lb/ft² per inch for galvanized/black iron (41.99 for 300-series stainless), roughly one-third the weight at equal thickness.
SMACNA Architectural Sheet Metal Manual (7th ed.), Appendix A, Table A-1 and Table A-5 notesBody belts used with fall restraint systems or positioning devices must limit maximum arresting force to 900 pounds (§1670(b)(13)), while the 1,800-pound limit of §1670(b)(11)(A) applies to a personal fall arrest system used with a body harness.
Cal/OSHA Title 8 Construction Safety Orders, §1670(b)(13)Control lines for a controlled access zone must have their lowest point including sag not less than 39 inches and highest point not more than 45 inches above the working level, while the 34-to-45-inch range applies to warning lines in roofing operations under §1730.
Cal/OSHA Title 8 Construction Safety Orders, §1671.2(a)(6)(B)Top rails must withstand 200 pounds per §1620(c), while mid-rails, screens, mesh, intermediate vertical members, solid panels and equivalent members must withstand at least 150 pounds (666 N) applied in any downward or outward direction at any point per §1620(d).
Cal/OSHA Title 8 Construction Safety Orders, §1620(d)Labels must be revised within six months of becoming aware of significant new hazard information (§5194(f)(11)), while the new information must be added to the SDS within three months (§5194(g)(5)).
Cal/OSHA Title 8 General Industry and Electrical Safety Orders, §5194(f)(11) and §5194(g)(5)High-heat procedures apply when the temperature equals or exceeds 95°F and require pre-shift meetings, observation, and water reminders for construction, whereas a heat wave (predicted high at least 80°F and at least ten degrees above the average high of the preceding five days) requires close observation of all employees by a supervisor or designee.
Cal/OSHA Title 8 General Industry and Electrical Safety Orders, §3395(e)Typical curved surface radius limits are 10 ft (3.1 m) for copper versus 15 ft (4.6 m) for prefinished metals; soft metals are used where the metal must be stretched.
SMACNA Architectural Sheet Metal Manual (7th ed.), Chapter 6, Figures 6-20 and 6-22 Mansard Roofs / Domes and Conical RoofsLadders on ladder-jack scaffolds may be up to 16 feet apart center to center generally, but not more than 12 feet apart where the platform is a single dressed 2-inch by 14-inch plank (§1648(b)).
Cal/OSHA Title 8 Construction Safety Orders, §1648(b)Key Terms
Formulas to Know
lb/ft² = thickness (in.) × material constant: 41.82 for galvanized and black iron, 41.99 for 300-series stainless, 41.20 for 400-series stainless, 14.258 for aluminum. Example: 0.050 in. × 41.99 = 2.10 lb/ft²; × 2,000 ft² ≈ 4,200 lb. Cost example: 0.030 in. × 41.82 = 1.25 lb/ft² × $0.90/lb ≈ $1.13/ft².Copper: lb/ft² = oz/ft² ÷ 16 (20 oz = 1.25 lb/ft²; 2,400 ft² × 1.25 = 3,000 lb). Lead: the '4 lb' designation means 4 lb per ft² (85 ft² × 4 lb = 340 lb; × $3.10/lb = $1,054).Rectangular: sq ft per linear foot = perimeter in feet = 2 × (W + H) ÷ 12; e.g., 2 × (36 + 24) = 120 in. = 10 sq ft/ft × 40 ft = 400 sq ft. Round: circumference (π × D) × length; e.g., 3.1416 × 2 ft = 6.28 sq ft/ft × 50 ft = 314 sq ft, × 1.10 for seams/waste ≈ 346 sq ft.GPM = 0.0104 × IPH × roof area in ft² (constant from 7.48 gal/ft³ ÷ 12 in./ft ÷ 60 min/hr). Example: 0.0104 × 8 × 12,000 = 998 gpm.Q = 3.33 (L − 0.2H) H^1.5, valid where the scupper opening length L is 4 to 8 times the head H.Design area = roof plan area × pitch factor; divide by number of downspouts, then divide by the local drainage factor. Example: 8,000 ft² × 1.05 = 8,400; ÷ 4 = 2,100; ÷ 160 = 13.1 in.² each. Related rate: about 96.15 sq ft of surface at 1 in./hr of rainfall produces 1 gpm; downspouts under 7.00 in.² should not be used except for porches and canopies; one downspout serves a practical maximum of 50 ft of gutter (140 ft ÷ 50 = 2.8 → 3 downspouts).Gutter: front high point set below the back edge 1 in. per foot of gutter width, with 1 in. absolute minimum (18 in. = 1.5 ft → 1 1/2 in.). Coping: top slopes 1/4 in. per foot of coping width toward the roof side.2d = 1 in. (25 mm); add 1/4 in. (6 mm) per size through 10d (6d = 2 in., 8d = 2 1/2 in.); sizes above 16d increase in 1/2 in. increments.Pieces = (run length in ft × 12) ÷ exposure per course, then × waste factor, round up: 85 ft × 12 ÷ 5 = 204 × 1.10 = 225 pieces; 42 ft × 12 ÷ 5 = 100.8 → 101 pieces. Stock sections = length (with waste applied once) ÷ section length, round up: 90 ÷ 10 = 9 × 1.10 = 10 sections; 42 × 1.10 = 46.2 ÷ 8 = 6 sections. Sheet stock: strips per sheet = sheet width ÷ girth, lineal ft per sheet = strips × sheet length (48 ÷ 8 = 6 × 10 ft = 60 ft; 640 × 1.10 = 704 ÷ 60 = 12 sheets).Movement % = (maximum joint width − minimum joint width) ÷ minimum joint width. Example: (7/8 − 5/8) ÷ 5/8 = 0.25 ÷ 0.625 = 40%.