Exam Cheat Sheet · Quick Reference
ICC F15 Shingle Roofing Exam (2015 IBC/IRC)
National · Pearson Vue
National State Portion 40 questions
Key Distinctions
Per the IRC 2015 R202 definitions, a metal roof panel is an interlocking metal sheet with an installed weather exposure of not less than 3 square feet per sheet, while a metal roof shingle has an installed weather exposure of less than 3 square feet per sheet.
IRC 2015 Section R202 (METAL ROOF PANEL; METAL ROOF SHINGLE)IBC 2015 Section 1507.2.9.3 requires underlayment to be installed over the drip edge along eaves, but drip edges to be installed over the underlayment along rake edges.
IBC 2015 Chapter 15 — Section 1507.2.9.3 Drip EdgeMetal roof shingle valley flashing extends not less than 8 inches from the centerline each way with a splash diverter rib not less than 3/4 inch high at the flow line, while tile and wood shingle/shake valley flashing requires an 11-inch extension and a 1-inch rib.
IBC 2015 Chapter 15 — Section 1507.5.7 FlashingAsphalt shingle nails are minimum 12-gage shank with a minimum 3/8-inch-diameter head, while tile fasteners are corrosion resistant and not less than 11 gage with a 5/16-inch head.
IBC 2015 Chapter 15 — Section 1507.2.6Both require corrosion-resistant fasteners not less than 11 gage, but the IBC states a 5/16-inch head while the IRC states a 7/16-inch head; both require penetration of the deck not less than 3/4 inch or through the deck thickness, whichever is less.
IBC 2015 Chapter 15 — Section 1507.3.6Per IRC 2015 Table R905.1.1(3), the cap nail shank shall be not less than 0.083 inch for ring shank cap nails and not less than 0.091 inch for smooth shank cap nails.
IRC 2015 Table R905.1.1(3)Shingle roofing nails require a minimum 12-gage (0.105-inch) shank, while the 0.091-inch minimum applies to smooth shank cap nails used for underlayment attachment, not shingle nails.
IRC 2015 Section R905.2.5Wood shingle No. 26 gage valley flashing extends 10 inches from the centerline each way for slopes less than 12:12 and 7 inches each way for slopes of 12:12 and greater, while wood shake valley flashing extends not less than 11 inches each way with end laps of not less than 4 inches.
IRC 2015 Section R905.7.6A roof recover is not permitted where the existing roof has two or more applications of any type of roof covering, so only one existing application may remain; a roof with two or more layers must be torn off down to the deck as a roof replacement.
IBC 2015 Section 1511.3.1.1IBC 2015 Section 1507.2.2 limits asphalt shingles to slopes of 2:12 or greater and requires double underlayment per Section 1507.2.8 from 2:12 up to 4:12; at 4:12 and steeper a single layer lapped 2 inches is permitted.
IBC 2015 Chapter 15 — Sections 1507.2.2 and 1507.2.8Both require a minimum 3/4-inch penetration into the sheathing, but asphalt shingle nails must penetrate through sheathing less than 3/4 inch thick, while wood shake fasteners must extend through sheathing only where it is less than 1/2 inch thick.
IBC 2015 Chapter 15 — Section 1507.2.6Per IBC 2015 Section 1504.3.2, standing-seam systems must be tested for wind resistance in accordance with ASTM E1592 or FM 4474, while through-fastened systems may be tested to FM 4474, UL 580 or ASTM E1592.
IBC 2015 Chapter 15 — Section 1504.3.2Asphalt shingles are normally tested for wind resistance to ASTM D7158; shingles not included in the scope of ASTM D7158 shall instead be tested and labeled for compliance with ASTM D3161 and the required classification.
IBC 2015 Section 1504.1.1In the absence of manufacturer's installation instructions, copper, brass, bronze, copper alloy and 300-series stainless steel fasteners shall be used for copper roofs, while galvanized fasteners are specified for steel roofs.
IRC 2015 Section R905.10.4Per IRC 2015 Section R905.7.5, fasteners installed within 15 miles of salt water coastal areas must be Type 316 stainless steel, while elsewhere Type 304 or 316 stainless or hot-dipped galvanized box nails meeting ASTM A153 Class D are permitted.
IRC 2015 Section R905.7.5Under IBC 2015 Section 105.3.2 the building official may grant one or more extensions for additional periods not exceeding 90 days each, whereas the residential code permits extensions of up to 180 days each.
IBC 2015 Section 105.3.2Key Terms
Formulas to Know
Lower edge of each 18-inch-wide felt strip is placed above the butt end of the shake it covers by a distance = 2 × weather exposure (so no felt is exposed).Nail length sufficient to penetrate the deck not less than 3/4 inch OR through the thickness of the deck, whichever is less (e.g., with a 1/2-inch plywood deck the nail penetrates through the deck).Nail long enough to penetrate through the roofing materials and not less than 3/4 inch into the sheathing; where sheathing is less than 3/4 inch thick (e.g., 5/8-inch sheathing), the nail must penetrate through the sheathing.Minimum 3/4-inch penetration into the sheathing; where sheathing is less than 1/2 inch thick, fasteners shall extend through the sheathing.Cap nail shank must penetrate through the sheathing or not less than 3/4 inch into it; shank not less than 0.083 inch (ring shank) or 0.091 inch (smooth shank), cap nominal diameter not less than 1 inch.Not less than 4 fasteners per strip shingle or 2 per individual shingle; where roof slope exceeds 21:12 (175-percent slope), install as required by the manufacturer.In areas subject to snow, not less than 2 fasteners per tile; the reduced attachment schedule of Table R905.3.7 applies only in other areas (example: 11 psf tile, solid sheathing without battens, 6:12 slope in a snow area = 2 fasteners per tile).Table R301.2(2) values are for a mean roof height of 30 feet in Exposure B; multiply by the height/exposure coefficient from Table R301.2(3) for the actual building (the 33-foot/Exposure C condition applies to the ultimate design wind speed map, not this table).For slopes of 3:12 (25-percent slope) and greater, provide a 36-inch-wide underlayment — one layer of Type I underlayment (IBC also permits ASTM D1970 self-adhering polymer-modified bitumen sheet) — running the full length of the valley, in addition to other required underlayment.Extends from the lowest edges of all roof surfaces to a point not less than 24 inches inside the exterior wall line of the building.