EN ES
National · Pearson VUE

ICC F15 Shingle Roofing Exam (2015 IBC/IRC)

ICC F15 Shingle Roofing (2015 IBC/IRC) exam study guide: the bulletin's key facts, the official outline, the reference books and sample questions with answers.

40 questions 120 minutes 70% to pass 4 topics 3:00 per question Open book 173 questions in pool Bulletin: June 2026
Full practice exam $9.95
  • 40 questions on a 120-minute clock, like the real exam
  • Every answer explained; code questions cite the book and section so you can find it in your own copy
  • A fresh draw from 173 questions each attempt
Try 10 free questions
Study Course $59.95/month
  • Unlimited full exams, topic quizzes and study briefs
  • Cancel anytime
See the study course
Not sure which exam you need? Text us: (813) 582-5360
Texts preferred · 9am–9pm Central
On this page

ICC F15 Shingle Roofing (2015 IBC/IRC) Exam Study Guide

This guide covers what you need for the ICC F15 Shingle Roofing (2015 IBC/IRC) exam: the key facts from the official bulletin, the topics it tests, the reference books, sample questions with answers, and a plan to prepare. Pearson VUE gives the exam.

ICC F15 Shingle Roofing (2015 IBC/IRC) Exam at a Glance

Here are the exam's key facts from the official bulletin:

Questions 40 questions
Time limit 2 hours
Passing score a minimum score of 70
Books in the exam room Open book
Exam fee $120

On exam day

  • Test questions are in four-option, multiple-choice format, with one answer on each question scored as correct.

References you may bring

  • International Building Code® (2015)
  • International Residential Code (2015)

Scheduling, changes and retakes

  • Exams are scheduled through PearsonVUE at www.pearsonvue.com/ICC, where candidates can create an account, schedule an exam, locate a test center, purchase vouchers and request accommodations.
  • Results for examinations taken electronically are available immediately after the examination is completed.
  • You must wait 10 days before retaking a failed exam.
  • After passing, contact the jurisdiction in which you wish to be licensed for any other requirements, because ICC is not a licensing agency.

Source: National Contractor/Trades Examination Information Bulletin, PUBLISHED June 30, 2026. Check the bulletin before test day: fees and rules can change.

What the ICC F15 Shingle Roofing (2015 IBC/IRC) Exam Covers

The official content outline has 4 topics:

Topic Questions Share of the exam
Job Planning and Setup 7 18%
Types of Roofing Material and Applications 9 23%
Fasteners, Flashings, Scuppers, Etc. 13 32%
Re-roofing 11 27%

How to Prepare for the ICC F15 Shingle Roofing (2015 IBC/IRC) Exam

Start with the books. This is an open-book exam, so the references on the bulletin's list are your main study tool. Get the editions the bulletin names.

Learn where things are. Read the table of contents and the index of each book until you know where every major subject lives. On test day, finding an answer fast matters more than memorizing it.

Highlight the sections you use most. Check the bulletin's rules on tabs and markings before you add any.

Spend most of your time on the biggest topics. Fasteners, Flashings, Scuppers, Etc. and Re-roofing make up 59% of the exam.

Take timed practice exams. The clock trains you to find answers at the pace the real exam needs: about 3 minutes per question.

Aim to pass more than once. One passing score can be luck. Several in a row means you're ready.

Reference Books for the ICC F15 Shingle Roofing (2015 IBC/IRC) Exam

The references listed for this open-book exam are the 2015 International Building Code and the 2015 International Residential Code.

Where to get them:

On Test Day

  • Go through the whole exam first. Answer every question you know and bookmark the ones you don't. Every exam lets you come back to bookmarked questions.
  • Then go back to your bookmarks and work them out.
  • Don't let one question eat your time. You have 2 hours for 40 questions, which is about 3 minutes per question.
  • Before you finish, answer anything you skipped. A blank can't earn a point.

Study Tips

Only select answers that directly respond to the question asked—not ones that merely sound correct or seem true. After choosing, verify your answer against the question to confirm you didn't misread it and that your selection genuinely addresses what was asked.

Our practice exam is specifically designed to mimic the testing conditions at all exam centers. While untimed PDF study guides might help with studying, they don’t prepare you for the challenge of managing your time during an actual test.

Before reading the answer choices, try to predict the correct answer based solely on the question. Your thinking is sharpest at this moment, before distractors cloud your judgment. Then scan the choices for your prediction—if it's there, you're likely right. A quick check of the remaining options is still worthwhile, but trust your instinct.

On an open-book exam, work through every question once: answer the ones you know and skip the ones you don't. Then go back to the ones you flagged. You can bookmark questions for later review, just like on our exams — and don't sink too much time into any single question. The clock is still running.

Sample ICC F15 Shingle Roofing (2015 IBC/IRC) Practice Questions

These questions come from our practice question bank, each with its answer and reference.

Sample 1 — Job Planning and Setup

Question: You are installing flashing where a shingle roof meets a parapet wall on a residential job. Where the flashing is metal, it must be corrosion resistant with a thickness of not less than what value?

  • A. 0.015 inch
  • B. 0.024 inch
  • C. 0.027 inch
  • D. 0.019 inch

Correct Answer: D

Per IBC 2015 Section 1503.2.1, flashing is required at wall and roof intersections, at gutters, wherever there is a change in roof slope or direction and around roof openings; where the flashing is metal, it must be corrosion resistant with a thickness of not less than 0.019 inch (No. 26 galvanized sheet). The 0.024-inch and 0.027-inch values are minimum thicknesses for aluminum and zinc alloy valley lining in Table 1507.2.9.2.

Reference: IBC 2015 Section 1503.2.1

Sample 2 — Fasteners, Flashings, Scuppers, Etc.

Question: Base flashing for an asphalt shingle roof may be corrosion-resistant metal of minimum nominal 0.019-inch thickness, or mineral-surfaced roll roofing weighing not less than:

  • A. 110 pounds per 100 square feet
  • B. 65 pounds per 100 square feet
  • C. 90 pounds per 100 square feet
  • D. 77 pounds per 100 square feet

Correct Answer: D

Per IBC Section 1507.2.9.1, base flashing shall be either corrosion-resistant metal of minimum nominal 0.019-inch thickness or mineral-surfaced roll roofing weighing a minimum of 77 pounds per 100 square feet. Cap flashing must be corrosion-resistant metal of minimum nominal 0.019-inch thickness.

Reference: IBC 2015 Section 1507.2.9.1

Sample 3 — Re-roofing

Question: An existing low-slope roof covering on a building is being replaced, and the roof provides positive roof drainage. Under the reroofing provisions, the work is not required to meet a minimum design slope of which value?

  • A. One-half unit vertical in 12 units horizontal
  • B. One-quarter unit vertical in 12 units horizontal
  • C. One-eighth unit vertical in 12 units horizontal
  • D. One unit vertical in 12 units horizontal

Correct Answer: B

IBC 2015 Section 1511.1, Exception 1 states that roof replacement or roof recover of existing low-slope roof coverings is not required to meet the minimum design slope requirement of one-quarter unit vertical in 12 units horizontal (2-percent slope) of Section 1507 for roofs that provide positive roof drainage. The other slopes listed are not the code's stated minimum design slope.

Reference: IBC 2015 Section 1511.1, Exception 1

Sample 4 — Types of Roofing Material and Applications

Question: You arrive to install wood shakes on a residence in a temperate climate and find the deck framed with nominal 1-inch by 4-inch spaced sheathing boards set 10 inches on center. What does the code require before the shakes are applied?

  • A. Replacement of the deck with solid sheathing
  • B. Two additional fasteners per shake at each board
  • C. Interlayment complying with ASTM D226, Type II
  • D. Additional 1-inch by 4-inch boards between the sheathing boards

Correct Answer: D

IBC 2015 Section 1507.9.1 (and Table 1507.8) states that where 1-inch by 4-inch spaced sheathing is installed at 10 inches on center, additional 1-inch by 4-inch boards shall be installed between the sheathing boards. Solid sheathing is required only in areas where the average daily January temperature is 25°F or less or where ice backup is possible, and interlayment for shakes is ASTM D226 Type I.

Reference: IBC 2015 Chapter 15 — Section 1507.9.1 Deck Requirements

Why Practice Online Instead of With a PDF

A PDF shows you questions. It doesn't show you the clock. Our practice exams are timed and on a screen, so you practice finding answers under time pressure, not just reading them. Each attempt draws a new set of questions from our bank, and your results break the score down by outline topic so you know what to study next.

Start Practicing

Take the free ICC F15 Shingle Roofing (2015 IBC/IRC) practice exam to see where you stand, then work through the topics that need attention. For the official rules, read the exam bulletin, and see the licensing board's website.

Frequently Asked Questions

How much does the ICC F15 Shingle Roofing Exam cost?
The exam fee is $120, paid through Pearson VUE when you register.
How many questions are on the ICC F15 Shingle Roofing Exam and how long do I have?
The exam has 40 multiple-choice questions and a 2-hour time limit.
What is the passing score for the ICC F15 Shingle Roofing Exam?
You must answer at least 70% of questions correctly to pass. After completing the exam electronically, your pass or fail result is available immediately.
Is the ICC F15 Shingle Roofing Exam open book?
Yes, the exam is open book. You may bring the 2015 International Building Code (IBC) and the 2015 International Residential Code (IRC) into the exam room.
What reference books are allowed in the ICC F15 exam?
The only approved references are the 2015 International Building Code and the 2015 International Residential Code. Presentations, study guides, and practice questions are not permitted.
How do I register for the ICC F15 Shingle Roofing Exam?
The exam is administered through Pearson VUE. Visit pearsonvue.com/ICC to create an account, schedule your exam, locate a test center, and purchase a test voucher.
What topics are covered on the ICC F15 Shingle Roofing Exam?
The exam covers four content areas: Job Planning and Setup (18%), Types of Roofing Material and Applications (23%), Fasteners, Flashings, Scuppers, Etc. (32%), and Re-roofing (27%).
How long do I have to wait before retaking the ICC F15 exam if I fail?
You must wait at least 10 days before retaking a failed exam. ICC strongly recommends using that time to study the approved references.
Will passing the ICC F15 Shingle Roofing Exam give me a license?
No. ICC is not a licensing agency. Whether your exam results satisfy licensing requirements is determined by the city, county, or state where you want to work, so you should check with that jurisdiction directly.
Should I guess on questions I don't know on the ICC F15 exam?
Yes — there is no penalty for guessing, so it is to your advantage to answer every question.

Reference books

2 books on the bulletin
As an Amazon Associate we earn from qualifying purchases.
Took this practice exam? Tell other candidates how it went.