Key Distinctions
A dwelling unit has complete independent living facilities with permanent provisions for living, sleeping, eating, cooking and sanitation, while a sleeping unit may have living, eating and either sanitation or kitchen facilities but not both.
IBC 2018 Chapter 2 (Definitions), 'Dwelling Unit' and 'Sleeping Unit'A structure is simply that which is built or constructed, while a building is any structure utilized or intended for supporting or sheltering any occupancy.
IBC 2018 Chapter 2 (Definitions), 'Building' and 'Structure'An approved agency is an established and recognized agency regularly engaged in conducting tests, furnishing inspection services or product certification and approved by the building official, while an approved source is an independent person, firm or corporation approved by the building official who is competent and experienced in applying engineering principles to materials, methods or systems analyses.
IBC 2018 Chapter 2 (Definitions), Section 202 — 'Approved Agency' (Book )A label carries the manufacturer's name, the function and performance characteristics of the product, and the name/identification of an approved agency indicating a representative sample was tested and evaluated; a mark shows only the manufacturer's name and the product's function.
IBC 2018 Chapter 2 (Definitions), Section 202 — 'Label'"Labeled" means an identifying label, seal, symbol or mark of a nationally recognized testing laboratory or approved agency has been affixed and that organization maintains periodic inspection of production, while "listed" refers only to inclusion in a published list (and "approved" means acceptable to the building official).
IBC 2018 Chapter 2 (Definitions), 'Labeled'An addition is an extension or increase in floor area, number of stories or height of a building (raising a roof to increase height is an addition even with no added floor area), while an alteration is any construction or renovation to an existing structure other than a repair or addition.
IBC 2018 Chapter 2 (Definitions), 'Addition'Stairway capacity is the occupant load served × 0.3 inch per occupant (without sprinkler/voice-alarm reductions), while components other than stairways use 0.2 inch per occupant.
IBC 2018 Section 1005.3.1Table 1004.5 assigns 15 net square feet per occupant to unconcentrated assembly arrangements versus 7 net for concentrated chairs-only and 5 net for standing space.
IBC 2018 Table 1004.5Occupant load for fixed seating without dividing arms is not less than one person per 18 inches of seating length, while booths are computed at one person per 24 inches of booth seat length measured at the backrest.
IBC 2018 Page 259For buildings sprinklered throughout with NFPA 13, the actual number of stories above grade plane (Sa) used in the area equation shall not exceed three, while the limit is four for buildings sprinklered per Section 903.3.1.2 (NFPA 13R), which is permitted in Group R up to four stories and not exceeding 60 feet above grade plane.
IBC 2018 Section 506.2.3Openable area for natural ventilation shall be not less than 4 percent of the floor area ventilated (Section 1202.5.1), while 8 percent applies to natural light glazing (Section 1204.2) and to openings between an interior room and an adjoining room.
IBC 2018 Section 1202.5.1Lateral force on crane runway beams with electrically powered trolleys is 20 percent of the sum of the rated crane capacity plus hoist and trolley weight, while longitudinal force (except bridge cranes with hand-geared bridges) is 10 percent of maximum wheel loads; 25 percent is a vertical impact value.
IBC 2018 Section 1607.14.3Key Terms
Formulas to Know
Stairway capacity = occupant load served × 0.3 inch per occupant (standard factor, without sprinkler/emergency voice alarm reductions)Capacity = occupant load served × 0.2 inch (5.1 mm) per occupantOccupant load = floor area ÷ occupant load factor (business areas: 150 gross sf/occupant; assembly without fixed seating, unconcentrated tables and chairs: 15 net sf/occupant). Where an area contains multiple functions with different factors, compute the floor area of each function independently.Aa = At + (NS × If), where NS is the tabular allowable area factor from Table 506.2 for a nonsprinklered building (used regardless of whether the building is sprinklered) and the sprinklered factor S1 is used only as the At valueIf = [F/P – 0.25] W/30; qualifying requires not less than 25 percent of the building perimeter on a public way or open spaceSa = actual number of stories above grade plane, not to exceed three for buildings sprinklered throughout with NFPA 13 (limit of four applies only to NFPA 13R per Section 903.3.1.2); no individual story may exceed the area determined using Sa = 1Vasd = V × √0.6 (Equation 16-33); example from Table 1609.3.1: V = 130 mph yields Vasd = 101 mphSDS = 2/3 × SMS (Eq. 16-38) and SD1 = 2/3 × SM1 (Eq. 16-39)Not less than 220 sf, plus 100 sf for each occupant in excess of two; worked example: 3 occupants = 220 + 100 = 320 sfGallons/bag = (W/C × 94 lb) ÷ 8.33 lb/gal; manual's example: 0.44 × 94 = 41.4 lb ÷ 8.33 ≈ 5.0 gallons per bag