ICC G14 Roofing Contractor Exam (2018 IBC/IRC/IPC)
National · Pearson Vue
National State Portion 60 questions
Key Distinctions
A roof recover installs an additional roof covering over a prepared existing covering without removing it, while a roof replacement tears off the existing covering and installs new covering (reroofing is the broader term covering both).
IRC 2018 Chapter 2 — definition of ROOF RECOVERIRC defines a built-up roof covering as two or more layers of felt cemented together and surfaced, whereas a modified bitumen roof covering is one or more layers of polymer modified asphalt sheets and a single-ply membrane uses one layer of membrane material.
IRC 2018 Chapter 2 — definition of BUILT-UP ROOF COVERINGWood shakes require interlayment complying with ASTM D226, Type I and are spaced 3/8 inch to 5/8 inch within a course, while Table 1507.8 lists 'no requirements' for interlayment under wood shingles and IRC R905.7.5 spaces shingles 1/4 inch to 3/8 inch.
IBC 2018 Pages 352 to 353Per IBC 1507.2.8.3 underlayment is installed over the drip edge along eaves, but the drip edge is installed over the underlayment along rake edges.
IBC 2018 Page 347IBC 1507.10.1 allows coal-tar built-up roofs a minimum design slope of 1/8 unit vertical in 12 units horizontal, while other built-up roofs require a design slope of not less than 1/4:12 for drainage.
IBC 2018 Page 353Without applied lap sealant the minimum slope is 3:12; with applied lap sealant the minimum is 1/2:12 (standing-seam metal panel systems may go as low as 1/4:12).
IBC 2018 Page 348Metal open valley lining shall be not less than 24 inches wide, while the two-ply roll roofing option uses an 18-inch bottom layer and a top layer not less than 36 inches wide.
IBC 2018 Page 347Asphalt shingle nails are minimum 12 gage (0.105 in) shank with 3/8-inch head (IRC R905.2.5); the minimum for clay and concrete tile is 11 gage with a 7/16-inch head (R905.3.6).
IRC Section R905.2.5Overflow drains of the same size as the roof drains are set with the inlet flow line 2 inches above the low point of the roof, while secondary scuppers shall not have an opening dimension of less than 4 inches.
IRC 2018 Page 432Under IRC R908.5 aggregate surfacing materials shall not be reinstalled, whereas sound slate, clay or cement tile may be reused.
IRC 2018 Section R908.5 Reinstallation of materialsIBC 103.2 has the chief appointing authority of the jurisdiction appoint the building official, while IBC 103.3 authorizes the building official to appoint deputies, technical officers, inspectors and plan examiners with the concurrence of the appointing authority.
IBC 2018 Section 103.3 (with Section 103.2)An annual permit may be issued only in lieu of individual permits for alterations to an already approved electrical, gas, mechanical or plumbing installation for a firm regularly employing qualified tradepersons; reroofing, demolition and new construction require individual permits.
IBC 2018 Section 105.1.1 (with Section 105.1.2)IBC permits above-deck insulation covered with an approved roof covering where it passes NFPA 276 or UL 1256 as an assembly, while IRC permits it where it complies with FM 4450 or UL 1256.
IBC 2018 Page 356Key Terms
Formulas to Know
Design area = projected roof area + (1/2 × vertical wall area). Worked example: wall 30 ft × 40 ft = 1,200 sq ft; half = 600 sq ft; 4,000 + 600 = 4,600 sq ft (IPC 1106.4).Lower edge of each 18-inch felt strip sits above the butt end of the shake it covers by 2 × weather exposure. Worked example: 24-inch shakes at 10-inch exposure → 2 × 10 = 20 inches (IRC R905.8.7).Use the manufacturer's specified number, but not fewer than 4 fasteners per strip shingle or 2 per individual shingle; where the manufacturer calls for fewer (e.g., 3 per strip), the code floor of 4 governs (IBC 1507.2.6).Extend from the lowest roof edges to not less than 24 inches inside the exterior wall line; where slope is 8:12 or greater, also extend not less than 36 inches measured along the roof slope from the eave edge (IRC R905.1.2).Slopes 2:12 up to 4:12 → double (two-layer) underlayment: 19-inch starter strip at the eave, then 36-inch sheets overlapped 19 inches; 4:12 and greater → single layer (IBC 1507.2.2, Table 1507.1.1(2)).Use the manufacturer's installation instructions where the ultimate design wind speed exceeds 130 mph, or where the roof is located more than 40 feet above grade; otherwise Table R905.3.7 may be used. In snow areas use not less than two fasteners per tile (IRC R905.3.7).Ground snow load 70 psf or less → prescriptive provisions of IRC Chapters 5, 6 and 8 permitted; greater than 70 psf → design in accordance with accepted engineering practice (IRC R301.2.3).Apply the liquid-applied protective coating not less than 2 hours nor more than 72 hours after application of the foam (IBC 1507.14.3).Where Vasd is greater than 110 mph, fasten underlayment along the overlap at not more than 36 inches on center; where Vasd is not less than 120 mph, also use ASTM D226 Type III, D4869 Type IV or D6757 attached in a 12-inch grid pattern between side laps with 6-inch spacing at side laps (IBC 1507.18.4.1).