Exam Cheat Sheet · Quick Reference

Kansas Journeyman Plumber with Gas Exam (ICC KGR, 2018 IPC/IFGC)

Kansas  ·  Pearson Vue

Verified, not estimated. Every figure below is drawn from the official exam structure we maintain — question counts, passing standard and topic weighting. Practice questions are grounded in the source law with statute citations. We omit any figure we can't verify rather than guess at it.
Total questions
70
Passing score
75%
Exam time
180 min
Administered by
Pearson Vue
Format
Reference materials allowed

Kansas State Portion 70 questions

Administration General Regulations 24 Q · 34%
General Installation RequirementsCode Definitions and TermsPlan ReadingTestingMaterialsPermits: application, issuance, expiration, and exemptionsDuties and authority of the code officialInspections: types, sequence, and approval requirementsViolations, stop work orders, and unsafe plumbing abatementMeans of appeal and board of appeals proceduresProtection of piping systems from physical damage, freezing, and structural impactTrenching, bedding, and backfill requirements for buried piping +4 more
Plumbing Fixtures 8 Q · 11%
Water HeatersWater Closets and UrinalsSpecialty FixturesBathtubs, Showers, Sinks, and LavatoriesMinimum Number of Required Plumbing Fixtures by OccupancyFixture Installation Requirements and ClearancesFaucets, Fixture Fittings, and Shower Valve Temperature LimitsFlushing Devices for Water Closets and UrinalsFixture Material Standards and Quality RequirementsWater Heater Safety Devices and Relief ValvesWater Heater Installation, Access, and ConnectionsAutomatic Clothes Washers, Dishwashers, and Food Waste Disposers +1 more
Water Supply and Distribution 8 Q · 11%
Service Distribution and PipingWater Supply and PressureProtection of Potable Water SupplyPipe Materials and Approved Standards for Water Service and DistributionJoining Methods and Connection Types by Pipe MaterialFixture Supply Pipe Sizing and Flow Rate RequirementsHot Water System Requirements and Temperature ControlsValve Placement and Shutoff RequirementsWater Pressure Regulation and Booster SystemsDisinfection of Potable Water SystemsIndividual Water Supply Sources and Well ConstructionChapter 6 Water Supply and Distribution
Sanitary Drainage 6 Q · 9%
Building Sanitary DrainageSumps and EjectorsIndirect and Special Waste SystemsDrainage pipe materials and applicable standards (above-ground, underground, and building sewer)Pipe joint types and methods by materialSlope and installation requirements for horizontal drainage pipingDrainage fixture unit values and system sizingCleanout requirements, placement, sizing, and accessBackwater valves for sewage backflow protectionDrainage fittings and permitted changes in directionPipe-bursting methods for replacement of underground building sewers and drainsChapter 7 Sanitary Drainage
Plumbing Vent Requirements 5 Q · 7%
Vent Connections and GradesVent TerminalsVent Pipe Sizing and Developed LengthTrap-to-Vent Distance and Fixture VentsAir Admittance ValvesWet Venting SystemsVent Stack and Relief Vent RequirementsVenting Methods (Individual, Common, Circuit, Combination Waste and Vent)
Traps, Interceptors, and Separators 5 Q · 7%
Installation of TrapsInterceptors and SeparatorsTrap seal depth requirements and protection methodsProhibited trap typesTrap sizing and dimensional requirementsGrease interceptor capacity and flow-through ratingsOil separator design and capacity requirementsSand, clothes washer, and specialty interceptorsVenting and access requirements for interceptors and separators
Storm Drainage 1 Q · 2%
Storm DrainageSizing of vertical conductors, leaders, and horizontal storm drains using rainfall rate tablesPrimary and secondary (emergency overflow) roof drains and scuppersProhibited connections and disposal requirements for storm waterApproved pipe materials for inside conductors, underground storm drains, and building storm sewersRoof drain installation requirements and flow rate calculationsStorm drainage traps: requirements, sizing, and cleanoutsSubsoil drain pipe materials and installationSiphonic roof drainage system requirements
Gas Piping 13 Q · 19%
Gas Piping for Service & Distribution PipingGas Piping Requirements, Specific Appliances EquipmentSource of Combustion Air & Duct OpeningsFuel-burning Appliance, Vent, ConnectorCSST bonding and electrical continuity requirementsPiping materials, standards, and prohibited materialsPipe sizing methods and use of sizing tablesPressure testing, inspection, and purging of piping systemsUnderground piping installation, burial depth, and corrosion protectionShutoff valves, appliance connectors, and flow controlsPiping support, bends, drips, and sediment trapsCombustion air requirements, indoor and outdoor methods +2 more

Key Distinctions

Horizontal pipevsVertical pipe

A horizontal pipe or fitting makes an angle of less than 45 degrees with the horizontal plane (so 40 degrees is horizontal), while a vertical pipe makes an angle of 45 degrees or more with the horizontal.

IPC 2018 Chapter 2 — Section 202, definitions of Horizontal Pipe and Vertical Pipe
Stack ventvsVent stack

A stack vent is the extension of a soil or waste stack above the highest horizontal drain connected to that stack, whereas a vent stack is a vertical vent pipe installed primarily to provide circulation of air to and from the drainage system.

IPC 2018 Chapter 2 — Section 202, definitions of Stack Vent and Vent Stack
Plumbing appurtenancevsPlumbing appliance

A plumbing appurtenance is an adjunct device that demands no additional water supply and adds no discharge load to a fixture or the drainage system, while devices dependent on energized components are plumbing appliances.

IPC 2018 Chapter 2 — Section 202, definitions of Plumbing Appurtenance and Plumbing Appliance
Full-open valvevsShutoff valve

Full-open valves are required at system locations such as the discharge side of every water meter, the water supply pipe to every water heater, the entrance to the structure, and the base of every water riser (in occupancies other than multiple-family residential two stories or less and one- and two-family dwellings), while shutoff valves are the valves required at individual fixture supplies.

IPC 2018 Sections 606.1 and 606.2
Fixture shutoff valve requiredvsFixture shutoff valve exempted

Shutoff valves are required on the supply to each plumbing fixture, except bathtubs and showers in one- and two-family residential occupancies and fixtures in individual sleeping units of hotels, motels and boarding houses that are provided with unit shutoff valves.

IPC 2018 Sections 606.1 and 606.2
S-trapvsDrum trap

S-traps are prohibited with no exception, while drum traps are prohibited but excepted where used as solids interceptors or serving chemical waste systems.

IPC 2018 Section 1002.3
ASSE 1018 trap seal primer valvevsASSE 1044 / ASSE 1072 devices

Potable water-supplied trap seal primer valves conform to ASSE 1018, while ASSE 1044 covers waste water-supplied trap primer devices and ASSE 1072 covers barrier-type trap seal protection devices.

IPC 2018 Section 1002.4.1.1
Longest length methodvsBranch length method

Under the longest length method every section and branch is sized from the table row for the system's longest run (not the branch's own short length), while under the branch length method each branch is sized using its own total length measured from the meter.

IFGC Section 402.4.1, Longest Length Method; Table 402.4(2), Schedule 40 Metallic Pipe (natural gas, 0.5 in. w.c. drop)
Fixtures required to discharge through a grease interceptorvsFood waste disposer

Pot sinks, prerinse sinks and floor drains into which kettles are drained must discharge through a grease interceptor, but a food waste disposer shall not discharge to a grease interceptor.

IPC 2018 Section 1003.3.2
Urinal substitution in assembly and educational occupanciesvsUrinal substitution in all other occupancies

Urinals shall not be substituted for more than 67 percent of required water closets in assembly and educational occupancies, while in all other occupancies the limit is 50 percent.

IPC 2018 Section 424.2
General separate-facilities exception (15 occupants)vsBusiness occupancy exception (25 occupants)

The general exception threshold for omitting separate facilities is an occupant load of 15, while the business-occupancy exception applies where the maximum occupant load is 25 or fewer; at 30 occupants neither applies and separate facilities for each sex are required.

IPC 2018 Section 403.2 Exception 4
Ordinary floor drain (2-inch minimum)vsLaundry room floor drain (3-inch minimum)

The general 2-inch minimum of Section 413.3 applies to ordinary floor drains, but rooms containing automatic clothes washers in public coin-operated laundries and central washing facilities of multiple-family dwellings require floor drains with outlets not less than 3 inches in diameter.

IPC 2018 Chapter 4, Section 413.4 — Public Laundries and Central Washing Facilities
Air test of cast-iron drainage/vent systemvsPlastic piping

A cast-iron drainage and vent system may be air tested at a uniform gauge pressure of 5 psi (or enough to balance a 10-inch mercury column) held not less than 15 minutes, but plastic piping shall not be tested with air.

IPC 2018 Chapter 3 — Section 312.3 Drainage and Vent Air Test
IPC scopevsInternational Residential Code scope

Detached one- and two-family dwellings and townhouses not more than three stories high with separate means of egress, plus their accessory structures, comply with the IRC, while buildings exceeding three stories and other occupancies such as hotels and apartment buildings remain under the IPC.

IPC 2018 Chapter 1 — Section 101.2 Scope

Key Terms

Branch interval IPC 2018 Chapter 2 — Section 202 General Definitions (Branch Interval)
A vertical measurement of distance of 8 feet or more in developed length between the connections of horizontal branches to a drainage stack, measured down the stack from the highest horizontal branch connection.
Backflow, low head backpressure IPC 2018 Chapter 2 — Section 202, definition of Backflow (Backpressure, low head)
A pressure less than or equal to 4.33 psi (29.88 kPa), or the pressure exerted by a 10-foot column of water.
Approved agency (required testing) IPC 2018 Chapter 1 — Sections 105.3 and 105.3.2 Required Testing/Testing Agency
The entity that must perform tests the code official requires where there is insufficient evidence of product compliance, with such tests made at no expense to the jurisdiction.
Bearing plane of a footing IPC 2018 Chapter 3 — Section 307.5 Protection of Footings
The zone whose upper boundary is a line extending downward at 45 degrees from horizontal from the outside bottom edge of the footing or wall; trenching parallel to footings and walls shall not extend into that plane.
Pipe sleeve through a foundation wall IPC 2018 Chapter 3 — Section 305.3 Pipes Through Foundation Walls
An alternative to a relieving arch, built into the wall and sized two pipe sizes greater than the pipe passing through it.
Protective sheathing (metallic piping at steel framing or masonry) IPC 2018 Section 305.1
Plastic sheathing not less than 0.008 inch (8 mil) thick used to prevent direct contact between metallic piping and steel framing members or masonry.
Water pressure-reducing valve IPC 2018 Section 604.8
An approved valve with strainer conforming to ASSE 1003 or CSA B356 required where static water pressure within a building exceeds 80 psi, reducing pressure to not greater than 80 psi static and designed to remain open to permit uninterrupted flow in case of valve failure.
Fixture trap liquid seal IPC 2018 Section 1002.4
The seal in each fixture trap, not less than 2 inches and not more than 4 inches deep, or deeper for special designs relating to accessible fixtures.
Trap seal primer valve discharge connection IPC 2018 Sections 1002.4.1.1 through 1002.4.1.3
The discharge pipe from a potable water-, reclaimed/graywater- or waste water-supplied trap seal primer valve, which shall connect to the trap above the trap seal on the inlet side of the trap.
Oil separator (garages and service stations) IPC 2018 Section 1003.4.2.2
A separator sized at not less than 6 cubic feet for the first 100 square feet of area drained plus 1 cubic foot for each additional 100 square feet, with not less than an 18-inch water seal at the outlet opening.
Gravity grease interceptor IPC 2018 Chapter 10, Section 1003.3.7
A grease interceptor whose capacity is determined by multiplying the peak drain flow in gallons per minute by a 30-minute retention time.
Flow-control device (hydromechanical grease interceptor) IPC 2018 Section 1003.3.5.2
A device controlling the rate of water flow to the interceptor that shall be vented and terminate not less than 6 inches above the flood rim level, or be installed per the manufacturer's instructions.
Clothes washer interceptor IPC 2018 Section 1003.6
An interceptor with a wire basket or similar device that prevents passage into the drainage system of solids 1/2 inch or larger, string, rags, buttons or other materials detrimental to the public sewage system.
Bottling plant interceptor IPC 2018 Section 1003.7
The device into which bottling plant process wastes must discharge, providing separation of broken glass or other solids before waste enters the drainage system.
Lead-free solder and flux IPC 2018 Section 605.13.6
Solder and flux used for joining water supply piping having a chemical composition equal to or less than 0.2-percent lead.
Heat-fusion joint (PE pipe) IPC 2018 Section 605.18.2
A joint made with surfaces clean and free from moisture, heated to melt temperature, joined and left undisturbed until cool, in accordance with ASTM D2657.
Water-hammer arrestor IPC 2018 Section 604.9
A device conforming to ASSE 1010, installed where quick-closing valves are utilized and in accordance with the manufacturer's instructions.
Booster pump low-pressure cutoff IPC 2018 Section 606.5.5
A cutoff required on all booster pumps to prevent creation of a vacuum or negative pressure on the suction side when a positive pressure of 10 psi or less occurs on the suction side.
Vacuum relief valve (water pressure tank) IPC 2018 Section 606.5.9
A valve not less than 1/2 inch in size provided at the top of a water pressure tank, operating up to a maximum water pressure of 200 psi and a maximum temperature of 200°F.

Formulas to Know

Minimum oil separator capacity for garages/service stationsCapacity = 6 cu ft for the first 100 sq ft drained + 1 cu ft for each additional 100 sq ft (example: 500 sq ft → 6 + 4 = 10 cu ft; 400 sq ft → 6 + 3 = 9 cu ft)
Minimum gravity grease interceptor capacityCapacity (gal) = peak drain flow (gpm) × 30-minute retention time (example: 40 gpm × 30 = 1,200 gallons)
Minimum depth of cover for exterior water supply pipingDepth = not less than 6 inches below the frost line and not less than 12 inches below grade (example: 18-in frost line → 18 + 6 = 24 inches)
Minimum urinal partition projection from the wallGreater of 18 inches, or (outermost front lip projection + 6 inches) measured from the finished backwall surface (example: 14 + 6 = 20 inches governs)
Converting appliance input to gas demand (natural gas, 1,000 Btu per cu ft)cfh = Btuh ÷ 1,000; reverse: Btuh = cfh × 1,000 (example: 44 cfh × 1,000 = 44,000 Btuh)
Section demand on a multi-outlet gas mainSection load = sum of the Btuh of all outlets served downstream ÷ 1,000 (examples: 40,000 + 35,000 + 100,000 = 175 cfh; past the last tee only the remaining appliance counts, e.g., 30,000 ÷ 1,000 = 30 cfh)
Spare (or short) capacity of an installed gas pipeSpare cfh = table capacity at that length − appliance demand (examples: 137 − 80 = 57; 117 − 40 = 77; 44 − 40 = 4; 237 − 230 = 7)
Longest length method sizing rowSize every section and branch from the table row for the system's longest run length, not the branch's own length (example: a 5-ft or 12-ft branch is sized on the 50-ft or 70-ft row)
Branch length method sizing lengthEach branch uses its own developed length measured from the meter (example: 15 ft main to tee 1 + 8 ft branch = 23 ft → use the 30-ft row); mains on the longest run use that run's row
Minimum female water closets from Table 403.1Female occupant load = total occupant load ÷ 2, then divide by the table ratio (example: restaurant, 150 total → 75 females ÷ 75 per WC = 1 water closet)
Pressure rating of threaded CPVC pipeThreaded pressure rating = rated pressure reduced by 50 percent, and the pipe wall thickness shall be not less than Schedule 80