North Carolina Electrical Contractor - Electric Sign (SP-ES)

North Carolina  ·  PSI Services Contractor

Verified, not estimated. Every figure below is drawn from the official exam structure we maintain — question counts, passing standard and topic weighting. Practice questions are grounded in the source law with statute citations. We omit any figure we can't verify rather than guess at it.
Total questions
40
Passing score
70%
Exam time
180 min
Administered by
PSI Services Contractor
Format
Reference materials allowed

North Carolina State Portion 40 questions

Bonding and Grounding 5 Q · 12%
Systems and equipment requiring grounding and ground-fault protectionLocation of connection and required interconnectionsGrounded, grounding, and grounding electrode conductorsConductor identification and color codingBonding jumpersEquipment grounding conductorsMethods of grounding and bonding, equipment and conductor specificationsLow-voltage specificationsBonding conductor connectionsTermination
Overcurrent Protection 4 Q · 10%
Location in circuitSizing requirementsCircuit breakersPlug and cartridge fusesEnclosures and locations
Wiring Methods and Terminations 8 Q · 20%
Permitted applications and usagesConduit and wireway fillPermitted applications and usagesCharacteristicsProtection from damagePermitted usages and ampacity ratingsCharacteristicsOutdoors
Boxes and Fittings 2 Q · 5%
General informationSizing requirements
Load Calculations 3 Q · 8%
Conductor ampacity requirementsOvercurrent protective device sizing
Appliances, Equipment, and Lighting 4 Q · 10%
Transformers
General 7 Q · 18%
DefinitionsInstallation requirements
Laws, Rules, Basic Business Practices, and Practical Applications 7 Q · 18%
Electrical Contractors Licensing Law (General Statutes Chapter 87, Article 4)Board’s Rules for the Implementation of the Electrical Contractors Licensing Law (Title 21, North Carolina Administrative Code, Chapter 18B)NASCLA Contractors’ Guide to Business, Law and Project Management -North Carolina Electrical Edition

Key Distinctions

OverloadvsFault (short circuit or ground fault)

An overload is operation of equipment in excess of normal, full-load rating that causes damage or dangerous overheating when it persists, while the NEC definition expressly states that a fault such as a short circuit or ground fault is NOT an overload.

NEC 2020 Article 100 — Definitions, Overload
Surge arrestervsSPD (surge-protective device)

A surge arrester limits surge voltages by discharging or bypassing surge current and prevents continued flow of follow current while remaining capable of repeating these functions, whereas an SPD limits transient voltages by diverting or limiting surge current.

NEC 2020 Article 100 — Definitions, Surge Arrester
Section signvsHost sign

A section sign is shipped as subassemblies that require field-installed wiring between the subassemblies to complete the sign, while a host sign is a sign or outline lighting system already installed in the field that is designated for field conversion of its illumination system with a retrofit kit.

NEC 2020 Section 600.2 (Definitions)
Sign bodyvsElectrode enclosure

A sign body is the portion of a sign that may provide protection from the weather but is NOT an electrical enclosure, while electrode enclosures under 600.42(H) are required to be listed enclosures.

NEC 2020 Section 2020 NFPA 70, Section 600.2 (Definitions)
LED sign illumination systemvsRetrofit kit

An LED sign illumination system is a complete lighting system of LED light sources, power supplies, wire, and connectors for signs and outline lighting, while a retrofit kit is the parts and hardware used for field conversion of a host sign.

NEC 2020 Section 2020 NFPA 70, Section 600.2 (Definitions)
600.21(D) working space at ballast/transformer/power supply not installed in a signvs600.21(E) attic/soffit passageway

600.21(D) requires a working space at least 3 ft high × 3 ft wide × 3 ft deep at each ballast, transformer, electronic power supply, or Class 2 power source (or its enclosure) where not installed in a sign, whereas the 3 ft high × 2 ft wide dimension is the attic/soffit passageway requirement of 600.21(E).

NEC 2020 Section 600.21(D)
InvertervsRectifier

An inverter is equipment that changes dc to ac, while a rectifier performs the opposite function (ac to dc); a transformer changes voltage levels within the same current type and a dc-to-dc converter changes dc voltage/current levels.

NEC 2020 Article 100 — Definitions, Inverter
Externally operablevsDead front / Enclosed / Guarded

Externally operable means capable of being operated without exposing the operator to contact with live parts; dead front means without live parts exposed on the operating side, enclosed means surrounded by a case or housing to prevent accidental contact, and guarded means covered, shielded, or otherwise protected to remove the likelihood of approach to a point of danger.

NEC 2020 Article 100 (Definitions, Part I — Externally Operable)
Feeder disconnect minimums for a one-family dwelling (225.39(C))vsFeeder disconnect minimums for two-circuit (225.39(B)) and all other (225.39(D)) installations

225.39(C) requires not less than 100 amperes, 3-wire for a one-family dwelling feeder disconnect, while 225.39(B) requires not less than 30 amperes for installations of not more than two 2-wire branch circuits and 225.39(D) requires not less than 60 amperes for all other installations (such as a detached garage fed by a feeder).

NEC 2020 Section 225.39(B)
GFCI protection at dwelling kitchen countertop receptacles (210.8(A)(6))vsAFCI protection for dwelling kitchen circuits (210.12(A))

GFCI protection is required for dwelling-unit receptacles serving countertop surfaces, while AFCI protection is separately required for all 120-volt, single-phase, 15- and 20-ampere branch circuits supplying outlets in dwelling unit kitchens — both are required.

NEC 2020 Section 210.8(A)(6) and 210.12(A)
Type AC cable minimum bend radiusvsInterlocked-armor/corrugated-sheath Type MC cable minimum bend radius

Type AC cable bends shall have an inner-edge radius not less than five times the cable diameter (320.24), while interlocked-type armor or corrugated sheath Type MC cable requires not less than seven times the external diameter of the metallic sheath (330.24(B)).

NEC 2020 Section 320.24
C corporationvsS corporation

Per the NASCLA Summary of Business Legal Structures table, a C corporation allows an unlimited number of shareholders with no personal liability and is taxed at the corporate level with a further tax on dividends (double taxation), while an S corporation is limited to 100 shareholders and uses pass-through taxation.

NASCLA Contractors Guide, North Carolina Electrical (14th ed.), Chapter 2 — Summary of Business Legal Structures table

Key Terms

Continuous load NEC 2020 Article 100
A load where the maximum current is expected to continue for 3 hours or more (Article 100), a definition critical for sizing conductors and overcurrent devices.
Overload NEC 2020 Article 100 — Definitions, Overload
Operation of equipment in excess of normal, full-load rating that, when it persists for a sufficient length of time, would cause damage or dangerous overheating; a fault such as a short circuit or ground fault is not an overload.
Surge arrester NEC 2020 Article 100 — Definitions, Surge Arrester
A protective device for limiting surge voltages by discharging or bypassing surge current that also prevents continued flow of follow current while remaining capable of repeating these functions.
Inverter NEC 2020 Article 100 — Definitions, Inverter
Equipment that changes dc to ac.
Neutral point NEC 2020 Article 100 — Definitions, Neutral Point
The common point on a wye connection in a polyphase system, or midpoint on a single-phase, 3-wire system, or midpoint of a single-phase portion of a 3-phase delta system, or a midpoint of a 3-wire dc system.
Demand factor NEC 2020 Article 100 — Definitions, Demand Factor
The ratio of the maximum demand of a system, or part of a system, to the total connected load of that system or part under consideration.
Uninterruptible power supply (UPS) NEC 2020 Article 100 — Definitions, Uninterruptible Power Supply
A power supply used to provide alternating current power to a load for some period of time in the event of a power failure.
Inverse time (circuit breaker) NEC 2020 Article 100 — Definitions, Circuit Breaker (Inverse Time)
A qualifying term indicating that a delay is purposely introduced in the tripping action of the circuit breaker, which delay decreases as the magnitude of the current increases.
Nonlinear load NEC 2020 Article 100 — Definitions, Nonlinear Load
A load where the wave shape of the steady-state current does not follow the wave shape of the applied voltage.
Available fault current NEC 2020 Article 100 — Definitions, Fault Current Available (Available Fault Current)
The largest amount of current capable of being delivered at a point on the system during a short-circuit condition.
Externally operable NEC 2020 Article 100 (Definitions, Part I — Externally Operable)
Capable of being operated without exposing the operator to contact with live parts.
Section sign NEC 2020 Section 600.2 (Definitions)
A sign or outline lighting system shipped as subassemblies that requires field-installed wiring between the subassemblies to complete the overall sign (600.2).
Host sign NEC 2020 Section 2020 NFPA 70, Section 600.2 (Definitions)
A sign or outline lighting system already installed in the field that is designated for field conversion of the illumination system with a retrofit kit (600.2).
Sign body NEC 2020 Section 2020 NFPA 70, Section 600.2 (Definitions)
A portion of a sign that may provide protection from the weather but is not an electrical enclosure (600.2).
LED sign illumination system NEC 2020 Section 2020 NFPA 70, Section 600.2 (Definitions)
A complete lighting system for use in signs and outline lighting consisting of light-emitting diode light sources, power supplies, wire, and connectors to complete the installation (600.2).
High-impedance grounded neutral system NEC 2020 Section 250.36
A system in which a grounding impedance limits the ground-fault current to a low value; permitted for 3-phase ac systems of 480 volts to 1000 volts provided all conditions of 250.36 are met.

Formulas to Know

Sign branch circuit sized as a continuous load (neon tubing example)Load × 1.25 = required conductor/OCPD size, then round up to the next standard rating per 240.6(A); example: 22 A × 1.25 = 27.5 A → 30 A device. Neon tubing branch circuits per 600.5(C)(1) may be rated up to but not in excess of 30 amperes.
Minimum ampacity of service conductors for a one-family dwelling, 100–400 A, single-phase 120/240 VService rating × 0.83 (not less than 83% of the service rating); example: 200 A × 0.83 = 166 A
Angle pull box minimum distance from raceway entry to opposite wall (314.28(A)(2))(6 × trade size of largest raceway) + sum of diameters of all other raceway entries on the same wall; example: (6 × 2) + 1 = 13 in.
Ampacity adjustment for 10–20 current-carrying conductors in a racewayTable ampacity × 50%; example: 10 AWG THHN 90°C = 40 A → 40 × 0.50 = 20 A
Ampacity adjustment for 7–9 current-carrying conductors in a raceway or cableTable 310.16–310.19 ampacity (as adjusted for ambient temperature) × 70%
Rooftop ambient temperature adder for raceways/cables in direct sunlight less than 7/8 in. above the roofOutdoor temperature + 33°C (60°F); example: 40°C + 33°C = 73°C (104°F + 60°F = 164°F)
Conductor ampacity where OCPD is rated over 800 A (supervised industrial, 240.91(B))Conductor ampacity ≥ 0.95 × OCPD rating; example: 1000 A × 0.95 = 950 A
Transformer 1000 V or less, primary-only protection, primary current 9 A or moreMaximum OCPD = 125% of rated primary current (shall not exceed); example: 12 A × 1.25 = 15 A, which is a standard rating, so 15 A is the maximum permitted
Transformer 1000 V or less, primary and secondary protection, secondary current 9 A or moreMaximum secondary OCPD = 125% of rated secondary current; if that value is not a standard rating, the next higher standard rating is permitted; example: 208 A × 1.25 = 260 A → 300 A
Creditable years of primary experience (21 NCAC 18B .0202(a))Creditable years = total primary hours ÷ 2,000 (2,000 hours = one creditable year); example: 11,000 ÷ 2,000 = 5.5 years