North Carolina Electrical Contractor - Electric Sign (SP-ES)
North Carolina · PSI Services Contractor
North Carolina State Portion 40 questions
Key Distinctions
An overload is operation of equipment in excess of normal, full-load rating that causes damage or dangerous overheating when it persists, while the NEC definition expressly states that a fault such as a short circuit or ground fault is NOT an overload.
NEC 2020 Article 100 — Definitions, OverloadA surge arrester limits surge voltages by discharging or bypassing surge current and prevents continued flow of follow current while remaining capable of repeating these functions, whereas an SPD limits transient voltages by diverting or limiting surge current.
NEC 2020 Article 100 — Definitions, Surge ArresterA section sign is shipped as subassemblies that require field-installed wiring between the subassemblies to complete the sign, while a host sign is a sign or outline lighting system already installed in the field that is designated for field conversion of its illumination system with a retrofit kit.
NEC 2020 Section 600.2 (Definitions)A sign body is the portion of a sign that may provide protection from the weather but is NOT an electrical enclosure, while electrode enclosures under 600.42(H) are required to be listed enclosures.
NEC 2020 Section 2020 NFPA 70, Section 600.2 (Definitions)An LED sign illumination system is a complete lighting system of LED light sources, power supplies, wire, and connectors for signs and outline lighting, while a retrofit kit is the parts and hardware used for field conversion of a host sign.
NEC 2020 Section 2020 NFPA 70, Section 600.2 (Definitions)600.21(D) requires a working space at least 3 ft high × 3 ft wide × 3 ft deep at each ballast, transformer, electronic power supply, or Class 2 power source (or its enclosure) where not installed in a sign, whereas the 3 ft high × 2 ft wide dimension is the attic/soffit passageway requirement of 600.21(E).
NEC 2020 Section 600.21(D)An inverter is equipment that changes dc to ac, while a rectifier performs the opposite function (ac to dc); a transformer changes voltage levels within the same current type and a dc-to-dc converter changes dc voltage/current levels.
NEC 2020 Article 100 — Definitions, InverterExternally operable means capable of being operated without exposing the operator to contact with live parts; dead front means without live parts exposed on the operating side, enclosed means surrounded by a case or housing to prevent accidental contact, and guarded means covered, shielded, or otherwise protected to remove the likelihood of approach to a point of danger.
NEC 2020 Article 100 (Definitions, Part I — Externally Operable)225.39(C) requires not less than 100 amperes, 3-wire for a one-family dwelling feeder disconnect, while 225.39(B) requires not less than 30 amperes for installations of not more than two 2-wire branch circuits and 225.39(D) requires not less than 60 amperes for all other installations (such as a detached garage fed by a feeder).
NEC 2020 Section 225.39(B)GFCI protection is required for dwelling-unit receptacles serving countertop surfaces, while AFCI protection is separately required for all 120-volt, single-phase, 15- and 20-ampere branch circuits supplying outlets in dwelling unit kitchens — both are required.
NEC 2020 Section 210.8(A)(6) and 210.12(A)Type AC cable bends shall have an inner-edge radius not less than five times the cable diameter (320.24), while interlocked-type armor or corrugated sheath Type MC cable requires not less than seven times the external diameter of the metallic sheath (330.24(B)).
NEC 2020 Section 320.24Per the NASCLA Summary of Business Legal Structures table, a C corporation allows an unlimited number of shareholders with no personal liability and is taxed at the corporate level with a further tax on dividends (double taxation), while an S corporation is limited to 100 shareholders and uses pass-through taxation.
NASCLA Contractors Guide, North Carolina Electrical (14th ed.), Chapter 2 — Summary of Business Legal Structures tableKey Terms
Formulas to Know
Load × 1.25 = required conductor/OCPD size, then round up to the next standard rating per 240.6(A); example: 22 A × 1.25 = 27.5 A → 30 A device. Neon tubing branch circuits per 600.5(C)(1) may be rated up to but not in excess of 30 amperes.Service rating × 0.83 (not less than 83% of the service rating); example: 200 A × 0.83 = 166 A(6 × trade size of largest raceway) + sum of diameters of all other raceway entries on the same wall; example: (6 × 2) + 1 = 13 in.Table ampacity × 50%; example: 10 AWG THHN 90°C = 40 A → 40 × 0.50 = 20 ATable 310.16–310.19 ampacity (as adjusted for ambient temperature) × 70%Outdoor temperature + 33°C (60°F); example: 40°C + 33°C = 73°C (104°F + 60°F = 164°F)Conductor ampacity ≥ 0.95 × OCPD rating; example: 1000 A × 0.95 = 950 AMaximum OCPD = 125% of rated primary current (shall not exceed); example: 12 A × 1.25 = 15 A, which is a standard rating, so 15 A is the maximum permittedMaximum secondary OCPD = 125% of rated secondary current; if that value is not a standard rating, the next higher standard rating is permitted; example: 208 A × 1.25 = 260 A → 300 ACreditable years = total primary hours ÷ 2,000 (2,000 hours = one creditable year); example: 11,000 ÷ 2,000 = 5.5 years