Exam Cheat Sheet · Quick Reference

North Carolina Electrical Contractor - Single-Family Detached Residential Dwelling (SP-SFD)

North Carolina  ·  PSI Services Contractor

Verified, not estimated. Every figure below is drawn from the official exam structure we maintain — question counts, passing standard and topic weighting. Practice questions are grounded in the source law with statute citations. We omit any figure we can't verify rather than guess at it.
Total questions
40
Passing score
70%
Exam time
180 min
Administered by
PSI Services Contractor
Format
Reference materials allowed

North Carolina State Portion 40 questions

Bonding and Grounding 5 Q · 12%
Systems and equipment requiring grounding and ground-fault protectionLocation of connection and required interconnectionsConductor identification and color codingBonding jumpersGrounding electrode conductorsEquipment grounding conductorsGrounding electrodesLow-voltage specificationsBonding conductor connectionsBonding/bonding gridTermination
Overcurrent Protection 4 Q · 10%
Location in circuitSizing requirementsCircuit breakersPlug and cartridge fusesEnclosures and locations
Wiring Methods and Terminations 3 Q · 8%
Permitted applications and usagesCharacteristicsConduit and wireway fillPermitted applications and usagesCharacteristicsProtection from damagePermitted usages and ampacity ratingsCharacteristicsMiscellaneousOutdoorsSwitchboards, panelboards, switches, and cabinetsSpecial conditions
Boxes and Fittings 4 Q · 10%
General informationSizing requirements
Service Entrance and Equipment 4 Q · 10%
Installation requirementsService equipmentGeneral sizing requirements
Motors and Control Wiring 2 Q · 5%
General informationBranch circuit and feeder ampacityOverload protectionShort-circuit and ground-fault protectionDisconnects/controllersSizeTypeLocationSeparation of conductors
Special Occupancies and Hazardous Locations 1 Q · 2%
Mobile homes and mobile home parksSwimming poolsUnderwater lighting fixtures
Load Calculations 4 Q · 10%
Branch circuitsTotal computed loadConductor ampacity requirementsLow-voltage
Appliances, Equipment, and Lighting 3 Q · 8%
Air conditionersResidential, commercial, and industrial equipmentLighting fixturesSpace heating equipment and boilersTransformers
General 2 Q · 5%
DefinitionsInstallation requirements
Laws, Rules, Basic Business Practices, and Practical Applications 8 Q · 20%
Electrical Contractors Licensing Law (General Statutes Chapter 87, Article 4)Board’s Rules for the Implementation of the Electrical Contractors Licensing Law (Title 21, North Carolina Administrative Code, Chapter 18B)NASCLA Contractors’ Guide to Business, Law and Project Management - North Carolina Electrical EditionNational Fire Alarm Code

Key Distinctions

NEC Chapter 8 (Communications Systems)vsNEC Chapters 1 through 7

Chapter 8 is NOT subject to the requirements of Chapters 1 through 7 except where those requirements are specifically referenced in Chapter 8.

NEC 2020 Section 90.3
Informational notes / explanatory materialvsEnforceable Code requirements

Informational notes are included for informational purposes only and are not enforceable as requirements of the Code.

NEC 2020 Section 90.5(C)
Straight pull box sizing (314.28(A)(1))vsAngle or U pull box sizing (314.28(A)(2))

A straight pull requires length not less than 8 times the trade size of the largest raceway, while an angle or U pull requires not less than 6 times the largest raceway trade size plus the sum of the diameters of the other raceway entries in the same row.

NEC 2020 Section 314.28(A)(1)
Optional dwelling calculation, NEC 220.82(B)vsExisting dwelling additional-load calculation, NEC 220.83(A)

220.82(B) takes 100 percent of the first 10 kVA plus 40 percent of the remainder, while 220.83(A) (no additional air-conditioning or electric space-heating equipment being installed) takes the first 8 kVA at 100 percent and the remainder at 40 percent.

NEC 2020 Section 220.82(B)
Feeder disconnect for not more than two 2-wire branch circuits (225.39(B)) — not less than 30 amperesvsFeeder disconnect for a one-family dwelling (225.39(C)) — not less than 100 amperes, 3-wire

Two-circuit installations require a disconnect rated not less than 30 amperes, while the one-family dwelling's feeder disconnecting means must be rated not less than 100 amperes, 3-wire.

NEC 2020 Section 225.39(B)
One-family dwelling feeder disconnect (225.39(C)) — not less than 100 amperesvsAll other installations (225.39(D)) — not less than 60 amperes

The 100-ampere minimum applies specifically to the one-family dwelling's feeder disconnect; a detached structure such as a garage supplied by a feeder falls under the 'all others' category at not less than 60 amperes unless it serves as the dwelling's main disconnect.

NEC 2020 Section 225.39(C)
Equipment grounding conductor at a separate building supplied by a feedervsGrounded conductor at that separate building

An equipment grounding conductor is run with the supply conductors and connected to the building disconnecting means and grounding electrode(s), but any installed grounded conductor shall NOT be connected to the equipment grounding conductor or to the grounding electrode(s) at the separate building or structure.

NEC 2020 Section 250.32(B)(1)
Motor overload initial sizing — 115 percent of nameplate FLCvsMotor overload maximum when the first selection will not start the motor — 130 percent of nameplate FLC

For 'all other motors' (no marked service factor of 1.15 or greater, temperature rise over 40°C), 430.32(A)(1) sizes the overload at 115 percent of nameplate FLC, and 430.32(C) permits a larger device whose trip current shall not exceed 130 percent; the 140 percent figure applies only to motors with a marked service factor of 1.15 or greater or the corresponding marked temperature rise.

NEC 2020 Section 430.32(C)
Feeder sized per NEC 2020, 215.2(A)(1)(a) — noncontinuous load plus 125 percent of continuous loadvsFeeder to an assembly listed for operation at 100 percent of its rating

Where the panelboard assembly is not listed for 100 percent operation, the conductor ampacity must be the noncontinuous load plus 125 percent of the continuous load; the simple sum of the loads is permitted only where the assembly is listed for 100 percent operation.

NEC 2020 Section 215.2(A)(1)(a)
20-ampere small-appliance branch circuitsvs15-ampere general-purpose branch circuits

Kitchen countertop receptacles specified by 210.52(B) must be served by the required 20-ampere small-appliance branch circuits, not by 15-ampere general-purpose circuits.

NEC 2020 Section 210.11(C)(1), 210.52(B)
Master alarm box (NFPA 72, 3.3.12.4)vsAuxiliary alarm box (3.3.12.1) / publicly accessible alarm box (3.3.12.5)

A master alarm box is publicly accessible and can ALSO be operated by remote initiating devices or an auxiliary alarm system, whereas an auxiliary alarm box can only be operated from remote initiating devices or an auxiliary system and a publicly accessible alarm box houses only a manually operated transmitter.

NFPA 72 National Fire Alarm and Signaling Code, Chapter 3 — 3.3.12 Alarm Box (3.3.12.1, 3.3.12.4, 3.3.12.5)
C CorporationvsS Corporation

A C corporation allows an unlimited number of shareholders with no personal liability and is taxed at the corporate level with a further tax on dividends (double taxation), while an S corporation is limited to 100 shareholders and uses pass-through taxation.

NASCLA Contractors Guide, North Carolina Electrical (14th ed.), Chapter 2 — Summary of Business Legal Structures table
Assumed name (DBA) certificate filed with the Register of DeedsvsFilings with the Secretary of State

A sole proprietor's assumed name certificate is filed at the Register of Deeds in each county of operation (there is no statewide name registration for sole proprietorships or general partnerships), while the Secretary of State handles corporations, LLCs, and limited partnerships.

NASCLA Contractors Guide, North Carolina Electrical (14th ed.), Chapter 2 — Naming Your Business / Assumed Name Filing section

Key Terms

Continuous load NEC 2020 Article 100
A load where the maximum current is expected to continue for 3 hours or more.
Interrupting rating NEC 2020 Section 110.9
Equipment intended to interrupt current at fault levels shall have an interrupting rating at nominal circuit voltage at least equal to the current that is available at the line terminals of the equipment.
High-leg marking (4-wire delta, midpoint of one phase grounded) NEC 2020 Section 110.15
The conductor or busbar having the higher phase voltage to ground shall be durably and permanently marked by an outer finish that is orange in color or by other effective means.
Multiwire branch circuit disconnecting means NEC 2020 Section 210.4(B)
Each multiwire branch circuit must be provided with a means that will simultaneously disconnect all ungrounded conductors at the point where the branch circuit originates.
Main bonding jumper that is a screw only NEC 2020 Section 250.28(B)
Where a main bonding jumper or system bonding jumper is a screw only, the screw shall be identified with a green finish that is visible with the screw installed.
Supply-side bonding jumper (separately derived system) NEC 2020 Section 250.30(A)(2)
Where the source of a separately derived system and the first disconnecting means are in separate enclosures, a supply-side bonding jumper shall be installed with the circuit conductors from the source enclosure to the first disconnecting means enclosure.
Effective ground-fault current path NEC 2020 Section 250.4(A)(5)
Per 250.4(A)(5), the earth shall not be considered as an effective ground-fault current path.
Grounding electrode system at a separate structure NEC 2020 Section 250.32(A)
A building or structure supplied by a feeder or branch circuit shall have a grounding electrode system and grounding electrode conductor installed per Part III of Article 250, and where none exists the electrode(s) required by 250.50 shall be installed.
Parallel conductors NEC 2020 Section 310.10(G)(1)
Aluminum, copper-clad aluminum, or copper conductors for each phase, polarity, neutral, or grounded circuit are permitted to be electrically joined at both ends only in sizes 1/0 AWG and larger.
Ampacity adjustment factor (7 to 9 current-carrying conductors) NEC 2020 Table 310.15(C)(1)
Where there are 7 to 9 current-carrying conductors in a raceway or cable, 70 percent of the values in Table 310.16 through Table 310.19 (as adjusted for ambient temperature if necessary) shall be applied.
Type AC cable bending radius NEC 2020 Section 320.24
The radius of the curve of the inner edge of any bend in Type AC cable shall not be less than five times the diameter of the cable.
Type AC cable securing NEC 2020 Section 320.30(B)
Unless otherwise permitted, Type AC cable shall be secured within 300 mm (12 in.) of every outlet box, junction box, cabinet, or fitting and at intervals not exceeding 1.4 m (4½ ft).
Box fill volume allowance, 12 AWG conductor NEC 2020 Table 314.16(B)
Each 12 AWG conductor requires a volume allowance of 2.25 in.³ (36.9 cm³) per Table 314.16(B).
Plug fuse identification (15 amperes and lower) NEC 2020 Section 240.50(C)
Plug fuses of 15-ampere and lower rating shall be identified by a hexagonal configuration of the window, cap, or other prominent part to distinguish them from fuses of higher ampere ratings.
Girder (NFPA 72, 3.3.37.2) NFPA 72 National Fire Alarm and Signaling Code, Chapter 3 — 3.3.37.2 Girder
A girder whose top is within 4 in. (100 mm) of the ceiling is a factor in determining the number and location of detectors and is considered a beam; if the top is more than 4 in. from the ceiling it is not a factor.
Suspension from practice (Board penalty) NASCLA Contractors' Guide to Business, Law and Project Management - North Carolina Electrical Edition, Chapter 3 — Disciplinary Action / Penalties section
Among penalties for prohibited activities such as false and misleading advertising, the Board may suspend a licensee from practice for a period not to exceed 12 months, in addition to reprimand, revocation, probationary revocation, or refusal to issue or renew.

Formulas to Know

Minimum length of a pull box for a straight pull (conductors 4 AWG or larger)Length ≥ 8 × trade size of the largest raceway. Worked example: largest raceway 3 in. (with two 2-in. conduits also entering) → 8 × 3 = 24 in. minimum.
Minimum distance from raceway entry to opposite wall for an angle or U pullDistance ≥ (6 × trade size of largest raceway in the row) + sum of the diameters of all other raceway entries in that same row. Worked examples: 2 in. + 1 in. entries → (6 × 2) + 1 = 13 in.; 4 in. + 2 in. entries → (6 × 4) + 2 = 26 in. governs (the 2-in. entry yields (6 × 2) + 4 = 16 in.).
Optional dwelling unit general calculated load (NEC 220.82(B); applies where served by a single 120/240-V or 208Y/120-V 3-wire set of service or feeder conductors with ampacity of 100 or greater)General load = 100% of the first 10 kVA + 40% of the remainder of the listed loads (not less than).
Existing dwelling unit calculation where no additional air-conditioning or electric space-heating equipment is installed (NEC 220.83(A))Load = 100% of the first 8 kVA of existing and new load + 40% of the remainder.
Optional method heating/air-conditioning selection (NEC 2020, 220.82(C))Include the largest of the listed selections; with four or more separately controlled electric space-heating units, 220.82(C)(5) permits 40% of nameplate. Worked example: 20 kVA × 0.40 = 8 kVA heating vs. 100% of 5 kVA A/C → include 8 kVA. (65% applies only where there are fewer than four separately controlled units.)
Service conductor ampacity for a one-family dwelling, service rated 100 through 400 amperes, single-phase 120/240 V (NEC 310.12(A))Conductors are permitted to have an ampacity not less than 83% of the service rating. Worked example: 200 A × 0.83 = 166 A.
Minimum feeder conductor ampacity (NEC 2020, 215.2(A)(1)(a); assembly not listed for 100% operation)Ampacity ≥ noncontinuous load + 125% of continuous load. Worked example: 28 A + (36 A × 1.25 = 45 A) = 73 A.
Motor overload device sizing for 'all other motors' (no marked service factor of 1.15 or greater; temperature rise over 40°C)Initial size = 115% of nameplate FLC (430.32(A)(1)); if that will not start the motor or carry the load, 430.32(C) permits a larger device whose trip current shall not exceed 130% of nameplate FLC. Worked example: 28 A × 1.15 = 32.2 A initial; maximum 28 A × 1.30 = 36.4 A.
Conductor ampacity between controller and a wye-start, delta-run motor (NEC 430.22(C))Ampacity ≥ 72% of the motor full-load current rating (58% carried by individual conductors × 1.25 = 72%).
Branch-circuit overcurrent protection for a single non-motor-operated appliance rated over 13.3 A with no marked protective device rating (NEC 422.11(E)(3))OCPD shall not exceed 150% of the appliance rated current; where 150% does not correspond to a standard rating, the next higher standard rating from 240.6(A) is permitted. Worked example: 22 A × 1.50 = 33 A → 35 A.