EN ES
Study Course

Alabama Roofing and Sheet Metal Contractor

60 questions 150 minutes 70% to pass 5 topics 2:30 per question Open book
Try 10 free questions Free Cheat Sheet Official Bulletin

Practice at the real exam's pace

Every practice exam shows your time per question against the real exam's clock (2:30 here), and each topic lands in one of these:

Ready Find it faster Study it Needs both Rushing: slow down

What's on the exam

Questions per topic, out of 60
Estimating and Plan Reading10
Surface Preparation and Planning8
Steep and Low Slope Roofing, including BUR, Waterproofing27
Roofing Components9
Safety6

Topics

Open a topic to read its key concepts

Estimating and Plan Reading

10 on exam · 254 practice questions

Topic: Estimating and Plan Reading

Key Concepts

  • Measure before you price. Measure the roof and calculate total area, then find the lengths of eaves, gables (rakes), ridges, hips and valleys. Use a 100-foot flexible tape with a grout hook; tapes highlighted at 5-inch intervals match the exposure of most composition shingles. Always make a sketch showing dimensions, slopes and penetrations. Errors in length and width matter far more than errors in ridge, hip or valley length (Ch. 1, Page 6).
  • Positive vs. negative method. The positive method divides an irregular roof into rectangles and adds their areas; the negative method extends the roof lines to form one large rectangle, then subtracts the areas lying outside the actual roof. Both give identical results — use whichever requires fewer calculations (Ch. 1, Pages 7–8, Examples 1-1 and 1-2).
  • Slope is rise in inches per 12 inches of run. A "6 in 12" roof rises 6 inches for every 12 inches of horizontal run (Page 10, Figure 1-9).
  • Pitch is Total Rise ÷ Total Span, where span is the horizontal distance from one eave to the other; Slope = 2 × Pitch (Page 11, Equations 1-5 and 1-6).
  • Roof slope can be read in degrees from the conversion table, Figure 1-12 (Page 12).
  • Plan lengths of eaves and ridges are actual lengths because they run horizontally; sloping members must be converted with slope factors (Page 18).
  • A roofing square is 100 square feet. Net roof area is the deck area to be covered; gross area adds starter courses, hip and ridge units, extra underlayment at ridges/hips/valleys, and cutting allowances at rakes, hips and valleys…

Surface Preparation and Planning

8 on exam · 85 practice questions

Alabama Roofing and Sheet Metal Contractor · 8 questions (13%)

Key Concepts

Roof deck slope - NRCA recommends roof deck slopes for asphalt shingle roof systems be specified at 4:12 or greater (NRCA Steep Slope, Section 2—Roof Decks). - Minimum slope for standard clay tile is 3 in 12; the underlayment spec calls for triple coverage with 30 lb felt followed by two plies of Type IV fiberglass at 3/12 and steeper (Underlayment on Sloping Roofs, Ch. 3).

Wood panel decks - Plywood for roof sheathing should meet or exceed PS 1, "Construction and Industrial Plywood" (NRCA Steep Slope, Section 2.1—Wood Panels). - NRCA minimums: four-ply, nominal ⅝-inch (actual 19/32") plywood at 16-inch rafter spacing; four-ply, nominal ¾-inch (actual 23/32") at 24-inch rafter spacing (Section 2.1). - Panel edge clips are recommended when panel sheathing of ½-inch nominal (actual 15/32") or less is installed over supports at 24 inches on center (Section 2.1). - Wood structural panel roof sheathing shall be manufactured with exterior glue (Exposure 1 or Exterior) (IBC 2304.8.2). Panels permanently exposed outdoors must be exterior type, except roof sheathing exposed on the underside, which may be Exposure 1 (IBC 2303.1.5). - APA recommends a minimum plywood grade of C-D Interior-and-Exterior Glue, or another equally durable exterior grade (Roof Sheathing, Decking and Loading, Ch. 2). - For OSB roof sheathing: "use a minimum ½ inch (nominal) panel" (Roofing Construction & Estimating, Ch. 2, p. 31).

Steep and Low Slope Roofing, including BUR, Waterproofing

27 on exam · 223 practice questions

Note: The SOURCE covers steep-slope systems, underlayments, and fire/wind classification. It does not address BUR composition, single-ply attachment methods, or roof insulation R-values, so those subtopics are not covered here.

Key Concepts

Material standards (IBC 2021) - Clay roof tile shall comply with ASTM C1167 (Section 1507.3.4); concrete roof tile shall comply with ASTM C1492 (Section 1507.3.5); slate shingles shall comply with ASTM C406 (Section 1507.7.5). - Asphalt shingles made from glass felt and surfaced with mineral granules: ASTM D3462, which addresses tear strength, fastener pull-through resistance, and pliability. NRCA recommends designers specify fiberglass-reinforced shingles complying with ASTM D3462 (NRCA Steep Slope, Section 4.1—Asphalt Shingle Standards). - Galvanized steel metal roof covering: minimum ASTM A653 G90 zinc-coated (IBC Table 1507.4.3(2)). Zinc roof covering minimum thickness 0.027 inch (IBC Table 1507.4.3(1)). - Wood shakes of naturally durable wood: minimum Grade 1 (IBC Table 1507.9.6). Wood shingles of naturally durable wood: Grade 1, 2, or 3, graded under CSSB rules (IBC Table 1507.8.5).

Minimum slopes (IBC 2021) - Slate: 4:12 or greater (Section 1507.7.2). Clay and concrete tile: 2½:12 (Section 1507.3.2). Metal roof shingles: not below 3:12 (Section 1507.5.2). NRCA recommends 4:12 minimum for slate and for metal shingle roof decks (NRCA Chapter 2—Roof Decks).

Fire classification (IBC 2021) - Class A = severe fire-test exposure (1505.2); Class B = moderate (1505.3); Class C = light (1505.4). Testing per ASTM E108 or UL 790 (1505.1). - Class A exceptions: minimum 16 oz/sq ft copper sheets over combustible decks (1505.2, Exc. 3); slate over ASTM D226 Type II underlayment over combustible decks (1505.2, Exc. 4). - Fire-retardant-treated wood shakes/shingles: impregnated by the full-cell vacuum-pressure process, per AWPA C1 (1505.6).

Roofing Components

9 on exam · 45 practice questions

Key Concepts

Roof deck and sheathing - Boards 1x4 through 1x12 may be used for solid sheathing, but nothing wider than 1 x 6 is recommended — wider boards swell and shrink excessively after installation (Roofing Handbook, Ch. 2). - Plywood under a built-up roof must have a panel span index of not less than 32/16 (unsanded) or Group 1 (sanded) — 32 inches between rafters, 16 inches between floor joists (Roofing Handbook, Ch. 2, Plywood Sheathing). - With spaced sheathing, solid sheathing runs from the eaves up to 12 to 24 inches beyond the interior face of the exterior wall line; some codes specify 36 inches on slopes less than 4 in 12 (Roofing Handbook, Ch. 2, Spaced Board Sheathing).

Underlayment - Fiberglass felts cost about 65 percent more than organic felts of the same weight, but don't rot or absorb water and are fire resistant (Roofing Handbook, Ch. 3). - Eaves flashing (ice shield) on slopes 4 in 12 and steeper extends at least 12 inches beyond the interior face of the exterior wall line (some codes require 24 inches); on slopes less than 4 in 12 the requirement is 24 inches (Roofing Handbook, Ch. 3, Eaves Flashing). - NRCA's preferred eave detail with water and ice-dam protection membrane — used for tile (TILE(IL)-3), wood shake (WOOD SHK(S)-3) and slate (SLATE-3) — starts with a self-adhering stripping ply applied directly to the deck and turned down the fascia a minimum of 1 inch, then drip edge metal, then the membrane over the drip edge flange.

Safety

6 on exam · 30 practice questions

Key Concepts

Fall protection — roof slope drives the answer - Low-slope roofs (slope ≤ 4 in 12) with unprotected sides/edges 6 feet or more above lower levels: guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and safety monitoring system — §1926.501(b)(10). - Safety monitoring system alone (no warning line) is permitted only on low-slope roofs 50 feet (15.25 m) or less in width — §1926.501(b)(10); App. A to Subpart M explains width is the lesser of the two primary dimensions. - Steep roofs (slope greater than 4 in 12), 6 feet or more: guardrail systems with toeboards, safety net systems, or personal fall arrest systems only — §1926.501(b)(11). Warning lines and safety monitors are not options.

Warning line systems — §1926.502(f) - Erected around all sides of the roof work area. - No mechanical equipment: not less than 6 feet (1.8 m) from the roof edge — (f)(1)(i). - Mechanical equipment in use: 6 feet from the edge parallel to equipment operation, 10 feet (3.1 m) from the edge perpendicular to it — (f)(1)(ii). - Flagged at not more than 6-foot intervals; lowest point (including sag) no less than 34 inches, highest point no more than 39 inches; stanchions resist 16 pounds applied horizontally 30 inches above the surface; rope/wire/chain minimum tensile strength 500 pounds — (f)(2).

Final Practice Exam
60 questions · 150 min · timed simulation of the real exam
Never the same exam twice. Every attempt is drawn fresh from 637 questions, about 10 full exams' worth, and questions you haven't seen come first.
Business and Law exam included
11 topics · 50 questions · 120 min

Required Books

Open-book exam
OSHA Standards for the Construction Industry
Buy on Amazon
2021 Edition
International Building Code 2021
Buy on Amazon
1995 (13th printing 2022)
Roofing Construction and Estimating
Buy on Amazon
2025 Edition
NRCA Roofing Manual: Steep Slope Roof Systems
Buy on Amazon
2023 Edition
NRCA Roofing Manual: Membrane Roofing Systems
Buy on Amazon
3rd Edition
NASCLA Contractors Guide to Business Law and Project Management, Alabama General
Buy on Amazon
As an Amazon Associate we earn from qualifying purchases.
$59.95/monthCancel anytime. Instant access.