Idaho Limited Electrical Limited Energy Installer Exam: A Practical Study Guide
The Idaho Limited Electrical Limited Energy Installer exam tests the rules and the reference books behind the work. This guide lays out the job: the key facts from the official bulletin, what the exam covers, the books you need, sample questions with answers, and how to get ready. PSI gives the exam.
The Idaho Limited Electrical Limited Energy Installer Exam at a Glance
Here's the rundown from the official bulletin:
| Questions | 40 questions |
| Time limit | 2 hours |
| Passing score | a minimum score of 70 |
| Books in the exam room | Open book |
| Exam fee | $75 |
On exam day
- You must present one current, government-issued photo and signature ID (such as a driver's license, state ID card, passport, military ID, or alien registration card) to be admitted.
- Arrive 15 minutes before your appointment time.
- Candidates must bring their own reference materials, and anyone caught writing in references or holding unauthorized materials has the binder seized and is reported to the Division.
- Highlighting, underlining and permanent indexing done before the exam are permitted, while writing during the session and temporary markers such as Post-its are prohibited.
- Only approved items may be brought into the exam room; all other personal belongings, including electronics, writing devices, bags, food and drinks, must be placed in secure storage.
References you may bring
- NFPA 70 – National Electrical Code (2017)
- Ferm's Fast Finder Index (2017)
- Key Word Index by Tom Henry (2017)
- Ugly's Electrical References
Scheduling, changes and retakes
- You may schedule online through PSI's registration website or by calling PSI at 855-340-3713.
- You may cancel and reschedule without forfeiting your fee if PSI receives your cancellation notice 2 days before the scheduled examination date, done by website or by phone (not voicemail or email).
- If you miss your appointment, arrive after the examination start time, cancel late, or lack proper ID, your registration is invalid and you forfeit your examination fee.
- Your score is shown on screen at the end of the exam and a score report is provided, with a diagnostic report of strengths and weaknesses if you fail.
- If you do not pass, you may retake the exam as many times as needed, paying an examination fee for each attempt.
Source: Examination Scheduling Procedures / Examination Guide (Idaho PSI Candidate Bulletin), Effective 7/9/2026. Check the bulletin before test day: fees and rules can change.
What the Idaho Limited Electrical Limited Energy Installer Exam Covers
The official content outline breaks the exam into 6 topics:
| Topic | Questions | Share of the exam |
|---|---|---|
| 2017 National Electrical Code, NFPA – Introduction | 6 | 15% |
| 2017 National Electrical Code, NFPA – Chapter 1 | 4 | 10% |
| 2017 National Electrical Code, NFPA – Chapter 2 | 3 | 8% |
| 2017 National Electrical Code, NFPA – Chapter 3 | 8 | 20% |
| 2017 National Electrical Code, NFPA – Chapter 7 | 18 | 45% |
| 2017 National Electrical Code, NFPA Calculations – Chapter 2 | 1 | 2% |
How to Get Ready for the Idaho Limited Electrical Limited Energy Installer Exam
Treat your reference books like your tools. On an open-book exam you don't need every rule memorized. You need to know which book holds it and where to find it.
Buy the books the bulletin lists, in the editions it names. An older or newer edition can put the answer on a different page, or change it.
Learn your way around each book before you study anything else. The table of contents and the index are your layout.
Highlight what you look up most. The exam facts above list the bulletin's rules on tabs and markings, so follow them exactly.
Do the big jobs first. 2017 National Electrical Code, NFPA – Chapter 7 and 2017 National Electrical Code, NFPA – Chapter 3 make up 65% of the exam.
Put in the reps with timed practice exams. The clock trains you to find answers at the pace the real exam needs: about 3 minutes per question.
Measure twice. When you miss a practice question, find the section in your book, read it and mark it. Keep at it until you pass practice exams consistently.
The Books for the Idaho Limited Electrical Limited Energy Installer Exam
The 2017 NFPA 70 National Electrical Code is the allowed reference, and the 2017 Ferm's Fast Finder Index, 2017 Key Word Index by Tom Henry and Ugly's Electrical References may also be used as optional references not used to develop the exam.
Where to get them:
Working the Exam on Test Day
Work the exam in two passes. On the first pass, answer everything you know and bookmark the rest. Every exam lets you come back to bookmarked questions, though some lock the ones you've seen once you take a break. On the second pass, go back to your bookmarks and take them one at a time.
Don't get hung up on one question. You have 2 hours for 40 questions, which is about 3 minutes per question. Before you finish, make sure nothing is left blank.
Study Tips
On an open-book exam, the winners aren't the smartest people in the room — they're the fastest at finding answers. Buy the required book, practice with it open, and tab and highlight each section the first time a question sends you there. Learn the index and table of contents until you can land on any topic in seconds. That speed is what separates a pass from a fail.
On an open-book exam, work through every question once: answer the ones you know and skip the ones you don't. Then go back to the ones you flagged. You can bookmark questions for later review, just like on our exams — and don't sink too much time into any single question. The clock is still running.
Give yourself at least three to six weeks. Use your exam's candidate bulletin as your roadmap for what's tested, and spend your time on finding-it-fast skills over rote memorization. In practice, aim for three clean passes at 80% or higher — setting your practice bar above the real cut score gives you a comfortable margin on test day.
Practicing against a ticking clock is the best way to beat exam-clock anxiety. Use these timed tests to build your pacing, so you learn to move steadily and never burn too long on a single question. By test day, the format feels routine.
Sample Idaho Limited Electrical Limited Energy Installer Questions
These come from our practice question bank, each with its answer and the reference behind it.
Sample 1 — 2017 National Electrical Code, NFPA – Chapter 1
Question: You are placing equipment operating at less than 1000 volts to ground above a lay-in ceiling, where installation instructions require it to be located in a space with limited access. What is the minimum size of the ceiling opening that must be provided?
- A. 22 in. × 22 in. (559 mm × 559 mm)
- B. 20 in. × 20 in. (508 mm × 508 mm)
- C. 22 in. × 30 in. (559 mm × 762 mm)
- D. 24 in. × 24 in. (610 mm × 610 mm)
Correct Answer: A
NEC 2017, Section 110.26(A)(4)(a) requires an opening not smaller than 559 mm × 559 mm (22 in. × 22 in.) where equipment is installed above a lay-in ceiling; the 22 in. × 30 in. dimension applies to an accessible opening in a crawl space.
Reference: NEC 2017 Section 110.26(A)(4)(a)
Sample 2 — 2017 National Electrical Code, NFPA – Chapter 2
Question: You are installing an intersystem bonding termination (IBT) on the exterior of a service equipment enclosure so that telephone, CATV, and future low-voltage systems can be bonded. The terminal device you select must provide capacity for the connection of not less than how many intersystem bonding conductors?
- A. Three
- B. Four
- C. Two
- D. Six
Correct Answer: A
NEC 2017, 250.94(A)(2) requires the intersystem bonding termination to consist of a set of terminals with the capacity for connection of not less than three intersystem bonding conductors. It must also be accessible and not interfere with opening the enclosure.
Reference: NEC 2017 Section 250.94(A)(2)
Sample 3 — 2017 National Electrical Code, NFPA Calculations – Chapter 2
Question: While calculating the service load for a single-family dwelling, you find the installed household electric clothes dryer has a nameplate rating of 4500 watts. What value must be used for the dryer in the feeder and service load calculation before any demand factor is applied?
- A. 4500 volt-amperes
- B. 5000 volt-amperes
- C. 3000 volt-amperes
- D. 5625 volt-amperes
Correct Answer: B
Per NEC 2017, 220.54, the load for a household electric clothes dryer in a dwelling unit shall be either 5000 watts (volt-amperes) or the nameplate rating, whichever is larger, for each dryer served. Since the nameplate is only 4500 VA, the 5000 VA minimum governs. The 5625 VA figure is simply 125 percent of nameplate, which this section does not require.
Reference: NEC 2017 Section 220.54
Sample 4 — 2017 National Electrical Code, NFPA – Chapter 7
Question: Which listed cable type is designated as limited-use, suitable for use in dwellings and in raceways, and listed as resistant to flame spread?
- A. Type CL2
- B. Type PLTC
- C. Type CL2R
- D. Type CL2X
Correct Answer: D
NEC 725.179(D) states that Types CL2X and CL3X limited-use cables shall be marked as such and listed as suitable for use in dwellings and raceways and as resistant to flame spread. Types CL2/CL3 are general-purpose (725.179(C)) and CL2R/CL3R are riser cables (725.179(B)).
Reference: NEC 2017 Section 725.179(D)