Exam Cheat Sheet · Quick Reference

California C-39 Roofing Contractor Exam

California  ·  PSI Services Contractor

Verified, not estimated. Every figure below is drawn from the official exam structure we maintain — question counts, passing standard and topic weighting. Practice questions are grounded in the source law with statute citations. We omit any figure we can't verify rather than guess at it.
Total questions
115
Passing score
72%
Exam time
210 min
Administered by
PSI Services Contractor
Format
Closed-book

California State Portion 115 questions

Planning and Estimating 25 Q · 22%
Planning roof projectsEstimating roof projectsMeasuring and calculating roof area (level and sloped surfaces, slope factor, net vs. gross area)Estimating material quantities by roof type (shingles, tile, membrane, metal panels, slate, wood shake)Labor unit pricing and production rate calculationsStructural and design load considerations (dead loads, live loads, wind uplift, snow loads, seismic)Building code compliance requirements for roof assemblies (CBC, CRC, fire classification, wind resistance testing)California Energy Code requirements affecting roof assemblies (solar reflectance, thermal emittance, insulation R-values)Wildland-Urban Interface and fire hazard zone requirements for roofing materialsClimatic and geographic design criteria affecting roof project planning (climate zones, ice barriers, wind speed maps)
Job Site Preparation for Roof Projects 15 Q · 13%
Protecting surroundingsCorrecting problemsTearing off existing roofingPre-job roof system evaluation and documentation reviewRoof deck inspection and assessment of surface conditionIdentifying and managing asbestos-containing roofing materials (Cal/OSHA requirements)Identifying hidden conditions (buried conduit, piping) in roof assembliesRoof deck types and substrate suitability for new roof systemsTemporary roof systems and weather protection during constructionUtility shutdown and hazardous material survey before demolition
Low-Slope Roof Projects 20 Q · 17%
Installing flashings, ventilation, and underlaymentInstalling various low-slope roof systemsRepairing low-slope roof systemsRigid board insulation types, R-values, and thermal performance requirementsAir and vapor retarders in low-slope roof assembliesRoof slope, drainage design, and ponding water criteriaMembrane surfacings including aggregate, coatings, and cool roof requirementsRoof accessories including equipment curbs, expansion joints, and penetration clearances
Steep-Slope Roof Projects 30 Q · 26%
Installing flashings, ventilation, and underlaymentInstalling various steep-slope roof systemsRepairing steep-slope roof systemsMinimum slope requirements for each steep-slope roofing materialFasteners, nailing patterns, and attachment methods for steep-slope coveringsFire classification requirements for roof coverings under CBC/CRC (Class A, B, C)Wind resistance and uplift requirements for steep-slope roof coveringsCondensation control, attic ventilation, and vapor retarder requirements for steep-slope assemblies
Safety 25 Q · 22%
Personnel safetyJob site safetyFall protectionInjury and Illness Prevention Program (IIPP) requirementsScaffolding requirements and safe useLadder selection, inspection, and safe usePersonal protective equipment (PPE) selection and useHazard communication and Safety Data Sheets (SDS)Heat illness prevention in outdoor constructionFire protection and flammable/combustible liquid storage on job sites

Key Distinctions

Metal roof panelvsMetal roof shingle

CBC 2022 Section 202 defines a metal roof panel as an interlocking metal sheet with a minimum installed weather exposure of 3 square feet per sheet, while a metal roof shingle is an interlocking metal sheet with installed weather exposure of less than 3 square feet per sheet.

California Building Code 2022, Section 202 (Metal Roof Panel; Metal Roof Shingle)
Roof expansion jointvsRoof area divider

Expansion joints are required where the deck material type changes (e.g., precast concrete abutting steel deck), at structural expansion joints, changes in framing/deck direction, separate wings of 'L,' 'U' or 'T' plans, additions, and junctions where interior heating conditions change; area dividers (raised curbs attached to the structural deck, flashed a minimum of 8 inches above the roof surface) are used where insulation thickness differs or new work abuts existing work with no change in deck type.

NRCA Roofing Manual: Membrane Roof Systems (2023), Section 2.1—Guidelines Applicable to All Roof Deck Types (Roof Expansion Joints; Roof Area Dividers)
Air intrusionvsAir leakage

ASTM D7586 defines air intrusion as indoor air entering a roof assembly but not escaping to the exterior (shown by a billowing mechanically attached membrane), whereas air leakage is air movement through the building envelope driven by positive (infiltration) or negative (exfiltration) pressure.

NRCA Roofing Manual: Architectural Metal Flashing, Condensation and Air Leakage Control, and Reroofing (2022), Condensation and Air Leakage Control, Chapter 4—Air Intrusion vs. Air Leakage
ASTM D4811 (non-vulcanized EPDM)vsASTM D4637 (cured EPDM)

ASTM D4811 is the standard for uncured (non-vulcanized) rubber sheet used as roof flashing, typically for field-fabricated flashing configurations, while ASTM D4637 covers the cured EPDM sheet used as the single-ply field membrane (ASTM D4434 is PVC and ASTM D6878 is TPO).

NRCA Roofing Manual: Membrane Roof Systems (2023), Section 5.4—Single-ply Roof Membranes (EPDM sheet flashings)
Architectural metal panel roof systemvsStructural metal panel roof system

Architectural panels are water-shedding rather than weatherproof and NRCA states they perform well on slopes of 3:12 or greater (lower slopes require careful evaluation and may need seam sealant or sealant tape), whereas 1/2:12 is the structural metal panel recommendation.

NRCA Roofing Manual: Metal Panel and SPF Roof Systems (2024), Metal Panel Roof Systems, Chapter 5, Section 5.1
Cricket flashingvsBacker flashing

NRCA recommends sloped cricket flashing on the upslope side of curbs more than 24 inches wide to promote drainage, while flat backer flashing does not redirect runoff and is limited to narrower units (24 inches wide or less).

NRCA Roofing Manual: Steep-slope Roof Systems (2025), Asphalt Shingle Roof Systems, Chapter 5—Roof Accessories, Section 5.1
Wood shake roof assemblyvsWood shingle roof assembly

Wood shakes require one course of interlayment felt for every course of shake to complete three layers of water-shedding coverage, while wood shingles achieve three-layer coverage by exposure alone and use no interlayment.

NRCA Roofing Manual: Steep-slope Roof Systems (2025), Wood Shake and Wood Shingle Roof Systems, Chapter 1—Roof Assembly Configurations
Safety factor 1.67 (steel deck with steel or aluminum metal panel roof system)vsSafety factor 2.0 (low-slope membrane roof systems)

Per AISI S100 and the Aluminum Design Manual, a 1.67 safety factor is applied to the ASD design wind load for a steel deck with a steel or aluminum metal panel roof system, while 2.0 is the safety factor used for low-slope membrane roof systems.

NRCA Roofing Manual: Membrane Roof Systems (2023), Appendix 1—Wind Uplift
Battens fastened with 8d nailsvsBattens fastened with staples

Nominal 1" x 2" battens attached with minimum 8d corrosion-resistant nails are spaced a minimum of 24 inches on center, but attachment with minimum 1-1/2" long, 7/16" crown, No. 16 gauge corrosion-resistant staples requires 12 inches on center (with 3/4" penetration into the deck or minimum 1/4" protrusion through the sheathing, whichever is less).

Concrete and Clay Roof Tile Installation Manual, Appendix A, MC-04 Layout Options—Battens, Note 4
Free-standing rolling scaffold, no ridersvsRolling scaffold moved with employees riding

Under §1646(a) a free-standing tower or rolling scaffold normally needs a base dimension of at least 1/3 its height, but §1646(i)(2) requires a minimum base dimension of at least 1/2 the height, when ready for rolling, where employees ride the scaffold as others move it (10 feet for a 20-foot-high scaffold).

Cal/OSHA Title 8 Construction Safety Orders, §1646(i)(2)
SPF in the field of the roof (40 psi)vsHigher-density SPF walkway (55 psi)

40 psi is the general minimum compressive strength recommended for SPF in the field of the roof, while higher-density SPF forming a traffic path or walkway should have a minimum compressive strength of 55 psi (25 psi corresponds to ASTM C1029 Type II).

NRCA Roofing Manual: Metal Panel and SPF Roof Systems (2024), SPF Roof Systems, Section 5.1—Walkways
Asbestos-containing material (ACM), >1 percentvsAsbestos-containing construction material, 0.1 percent

Under §1529(b) ACM is any material containing more than one percent asbestos, while the one-tenth of 1 percent figure applies to the separate definition of 'asbestos-containing construction material' used for consultant certification and asbestos-related work registration.

Cal/OSHA Title 8 Construction Safety Orders, §1529(b)

Key Terms

Metal roof panel California Building Code 2022, Section 202 (Metal Roof Panel; Metal Roof Shingle)
Per CBC 2022 Section 202, an interlocking metal sheet having a minimum installed weather exposure of 3 square feet per sheet.
Metal roof shingle California Building Code 2022, Section 202 (Metal Roof Panel; Metal Roof Shingle)
Per CBC 2022 Section 202, an interlocking metal sheet having an installed weather exposure of less than 3 square feet per sheet.
Air intrusion NRCA Roofing Manual: Architectural Metal Flashing, Condensation and Air Leakage Control, and Reroofing (2022), Condensation and Air Leakage Control, Chapter 4—Air Intrusion vs. Air Leakage
Per ASTM D7586, the mechanism by which indoor air enters into a roof assembly but does not escape to the exterior environment.
Air leakage NRCA Roofing Manual: Architectural Metal Flashing, Condensation and Air Leakage Control, and Reroofing (2022), Condensation and Air Leakage Control, Chapter 4—Air Intrusion vs. Air Leakage
Movement of air through the building envelope driven by positive pressure (infiltration) or negative pressure (exfiltration).
Roof expansion joint NRCA Roofing Manual: Membrane Roof Systems (2023), Section 2.1—Guidelines Applicable to All Roof Deck Types (Roof Expansion Joints; Roof Area Dividers)
A joint required where the deck material type changes, at structural expansion joints, at changes in framing or deck direction, at separate wings of 'L,' 'U' or 'T' configurations, at additions to existing buildings, and at junctions where interior heating conditions change.
Roof area divider NRCA Roofing Manual: Membrane Roof Systems (2023), Section 2.1—Guidelines Applicable to All Roof Deck Types (Roof Expansion Joints; Roof Area Dividers)
A raised curb attached to the structural deck and flashed a minimum of 8 inches above the roof surface, used where insulation thicknesses differ or where new work abuts existing work with no change in deck type.
ASTM D4811 NRCA Roofing Manual: Membrane Roof Systems (2023), Section 5.4—Single-ply Roof Membranes (EPDM sheet flashings)
'Standard Specification for Non-Vulcanized Rubber Sheet Used as Roof Flashing' — the U.S. product standard for uncured (non-vulcanized) EPDM used in field-fabricated flashing applications.
Standard Weight Rooftile Concrete and Clay Roof Tile Installation Manual, Appendix C, Glossary of Terms (Standard Weight Rooftile)
Roof tile with a mass/unit area of 9 lbs/ft² or greater installed weight, excluding all other roofing components such as underlayment, battens and fasteners.
Re-covering NRCA Roofing Manual: Steep-slope Roof Systems (2025), Chapter 6—Reroofing, Section 6.1—Definitions
Installing an additional roof covering over a prepared existing roof covering without removing it; it is one form of reroofing, which is defined as re-covering, or tearing off and replacing, an existing roof covering.
Asbestos-containing material (ACM) Cal/OSHA Title 8 Construction Safety Orders, §1529(b)
Under the construction asbestos standard §1529(b), any material containing more than one percent asbestos.
Lead permissible exposure limit (PEL) Cal/OSHA Title 8 Construction Safety Orders, §1532.1(c)(1)
Under §1532.1(c)(1), 10 micrograms per cubic meter of airborne lead as an 8-hour time-weighted average, except for the temporary abrasive-blasting limit of 25 µg/m³ allowed until January 1, 2030 (2 µg/m³ is the action level).
Heating-degree days (HDD65) NRCA Roofing Manual: Architectural Metal Flashing, Condensation and Air Leakage Control, and Reroofing (2022), Condensation and Air Leakage Control, Chapter 1, Section 1.3—Climate Conditions
The difference between 65 F and the outdoor mean temperature for days when the mean is less than 65 F, summed annually to help set the climate zone number (0 through 8).
Cooling-degree days (CDD50) NRCA Roofing Manual: Architectural Metal Flashing, Condensation and Air Leakage Control, and Reroofing (2022), Condensation and Air Leakage Control, Chapter 1, Section 1.3—Climate Conditions
The difference between 50 F and the outdoor mean temperature for days when the mean exceeds 50 F, summed annually to help set the climate zone number (0 through 8).
Ridge rafter Roofing Construction and Estimating, Chapter 1, Rafters (Figure 1-16)
A common rafter that runs parallel to the ridge board (as distinct from a hip rafter running diagonally from an outside corner to the ridge, a hip jack, or a valley jack).
Sheet lead (roof flashing) NRCA Roofing Manual: Architectural Metal Flashing, Condensation and Air Leakage Control, and Reroofing (2022), Architectural Metal Flashing, Chapter 1 (Lead) and Appendix 2
Flashing material designated by weight rather than gauge, typically specified at 2 to 4 pounds per square foot for roof system applications, with heavier weights desirable where soldering is necessary.
Trailing letter in NRCA detail numbers (e.g., ASPH-3A) NRCA Roofing Manual: Steep-slope Roof Systems (2025), Asphalt Shingle Roof Systems, Chapter 7—Construction Details, Introduction
The letter following the roof system delineation and detail number identifies NRCA's order of preference, with the lettered versions being alternatives NRCA also considers acceptable within stated limitations.

Formulas to Know

Net (actual) roof area in squaresNet roof area = roof plan area × roof-slope factor; squares = sq ft ÷ 100. Example: (34 × 24) × 1.158 = 945 sq ft = 9.45 squares; (36 × 24) × 1.414 = 1,222 sq ft = 12.22 squares; (48 × 20) × 1.118 = 1,073 sq ft = 10.73 squares. Separate-slope areas (e.g., a porch) are taken off separately with their own factor: 20 × 10 × 1.031 = 206 sq ft.
Common rafter (sloped) length, eave to ridgeRun = half the roof width; rafter length = run × common-rafter factor (e.g., 10 × 1.414 = 14.14 ft; 12 × 1.250 = 15.00 ft). Equivalently rafter = sqrt(run² + rise²) (e.g., sqrt(28² + 14²) = 31.30 ft; sqrt(31.50² + 21.00²) = 37.86 ft). A porch that is a single plane uses its full depth as the run (10 × 1.031 = 10.31 ft).
Hip length (actual, for hip-cap material)Run of each hip = half the roof width; actual hip length = run × hip-or-valley factor; four hips = 4 × that length (e.g., 12 × 1.530 = 18.36 ft, ×4 = 73.4 lin ft; 12 × 1.732 = 20.78 ft, ×4 = 83.1 lin ft). True hip from components: sqrt(plan run² + plan run² + rise²) = sqrt(18² + 18² + 9²) = 27.00 ft.
Ridge length on a rectangular hip roof with equal slopesRidge = Length − Width (hips rise at 45° in plan, so each hip end sits half the width in from the end wall): 34 − 24 = 10 ft; 48 − 20 = 28 ft; 60 − 36 = 24 ft.
Total rise above the eave line and ridge elevationRise = (slope ÷ 12) × run, where run = half the span (e.g., (6 ÷ 12) × 28 = 14.00 ft; (5 ÷ 12) × 10 = 4.17 ft = 4'-2"; (8 ÷ 12) × 31.50 = 21.00 ft). Ridge elevation = top-of-wall elevation + rise (9.00 + 14.00 = 23.00 ft; 12.00 + 21.00 = 33.00 ft).
Pieces or courses at a given exposure (Equation 4-3)Units = (length in feet × 12) ÷ exposure in inches, rounded up. Hip and ridge cap at 5-in exposure: (10 ft ridge + 73.4 ft hips) = 83.4 ft × 12 ÷ 5 = 200.3 → 201 units. Shingle courses per side: 15.05 ft × 12 ÷ 5 = 36.1 → 37 courses. Step flashing at 5-in exposure: 42 ft × 12 ÷ 5 = 100.8 → 101 pieces (add waste before rounding if specified: 204 × 1.10 = 224.4 → 225 pieces).
Bundles of 3-tab asphalt shinglesBundles = net area in squares × waste factor × 3 bundles per square, rounded up (9.45 × 1.05 × 3 = 29.8 → 30 bundles at 5% waste; 12.22 × 1.10 × 3 = 40.3 → 41 bundles at 10% waste; 25.33 × 3 × 1.10 = 83.6 → 84 bundles).
Rolls of 15-lb saturated feltRolls = squares × 1.05 (laps and waste) ÷ 4 squares per roll, rounded up (13.57 × 1.05 = 14.25 ÷ 4 = 3.56 → 4 rolls; 6.50 × 1.05 = 6.82 ÷ 4 = 1.71 → 2 rolls).
Material allowance factor (Equation 1-12)Allowance factor = area covered including allowances ÷ net roof area (19.2 ÷ 16 = 1.20, a 20 percent material allowance); gross area is always the larger figure you buy material for, net area is only the deck actually covered.
Minimum recommended design uplift-resistance capacityDesign uplift-resistance capacity = ASD design wind load × safety factor (1.67 for steel deck with steel or aluminum metal panel roof system; 2.0 for low-slope membrane roof systems). Example: 60 psf × 1.67 ≈ 100 psf.