Oklahoma HVACR Journeyman Limited
Code edition notice: Oklahoma's PSI candidate bulletin (effective August 31, 2026) allows either the 2018 or the 2024 edition of the International Mechanical Code (IMC) and International Fuel Gas Code (IFGC) on this exam from September 14, 2026 through December 13, 2026. Starting December 14, 2026, only the 2024 editions are permitted.
This practice exam now cites the 2024 edition section numbers. If you are studying from the 2018 book, most section numbers are unchanged; the Chapter 1 administrative sections were renumbered in 2024. If you test on or after December 14, 2026, study from and bring the 2024 books.
Practice at the real exam's pace
Every practice exam shows your time per question against the real exam's clock (3:00 here), and each topic lands in one of these:
What's on the exam
Questions per topic, out of 60Topics
Electrical Knowledge and Controls
Oklahoma HVACR Journeyman Limited
Key Concepts
Ohm's law and Watt's law. Ohm's law: R = E ÷ I, I = E ÷ R, E = I × R (Ch. 13, Basic Electricity, Sec. 13.1.3, p. 256–257). With voltage held constant, current and resistance are inversely related — lowering resistance increases current. Watt's law: P = I × E (Ch. 14, Electrical Power, Sec. 14.1.1, p. 273).
Series circuits. The same current flows through every load (Sec. 13.3.2, p. 261). If any one device opens — a switch, fuse, or safety limit — the circuit is broken and no current flows to any device. The sum of all individual voltage drops equals the total applied voltage (Sec. 13.3.5, p. 264). For series-parallel circuits, start with the farthest combination of loads and work backward (Sec. 13.3.4, p. 263).
Diagrams. Ladder diagrams: the two vertical lines are the power supply (rails); horizontal rungs are individual circuits containing controls and loads (Ch. 18, Sec. 18.2.1, p. 368). Ladder diagrams reflect order of operation — devices near the top energize before devices further down. Pictorial diagrams show the approximate physical location of devices in a unit and may give wire colors (Sec. 18.2.2, p. 369).
Natural Gas
Key Concepts
Sizing the system (IFGC Chapter 4 / Appendix A) - Maximum gas demand is "the sum of the maximum input of the appliances served," using the total connected hourly load and assuming all appliances could operate at full capacity simultaneously; the flow rate must be adjusted for altitude where the installation is above 2,000 feet (Section 402.2). - Piping is sized from the tables in Section 402.4 or from Equations 4-1 (low pressure, less than 1½ psi) and 4-2 (1½ psi and above); pipe length is determined per Section 402.4.1, 402.4.2 or 402.4.3 (Section 402.4). - Table 402.4(2) is Schedule 40 metallic pipe, natural gas, inlet pressure less than 2 psi, 0.5 in. w.c. pressure drop, specific gravity 0.60. Table 402.4(1) is the same pipe at 0.3 in. w.c. drop — read the drop before you read the row. - Longest length method (Section 402.4.1; Appendix A, A.3.1): find the length from the point of delivery to the most remote outlet; pick that row, or the next longer row if the exact length is not listed; "this is the only length used in determining the size of any section of gas piping." - Branch length method (Section 402.4.2; A.3.2): the longest meter-to-most-remote-appliance distance sizes the main sections feeding that appliance; every other branch is sized on its own distance from the outlet of the gas meter to that appliance. -…
Air Distribution Systems
Oklahoma HVACR Journeyman Limited
Key Concepts
Duct system types (Modern Refrigeration and Air Conditioning, 22nd ed., Ch. 30 — Air Distribution, p. 672; 20th ed. p. 755) - Radial duct system — individual branch ducts run directly from the central plenum to each supply outlet, with no trunk line. - Perimeter loop system — used with downflow furnaces in homes without basements; ductwork is laid out in the concrete slab, branch ducts connect to a perimeter duct, and diffusers connect at intervals along the floor. In a downflow furnace, return air enters at the top and supply air exits at the bottom. - SDHV (small duct, high-velocity) — small-diameter ducts, supply air to the inside perimeter of the building, return air originating from the center (p. 666; 20th ed. p. 748). - Also listed: extended plenum and reducing trunk systems. - Basement return branches commonly use the joists and floorboards for three sides of the branch duct (panned joist space) (p. 672).
Duct design guidelines (Ch. 30, Section 30.1, p. 696; 20th ed. p. 769) - Never install a duct in the end of a plenum — always install ducts in the sides, because a duct in the end receives too much airflow. Install the blower/air handler in a central location and keep duct runs as short as practical.
Refrigeration and Air Conditioning Systems
Key Concepts
Cycle dividers and components. The compressor is one of the two dividers between the low side and the high side — it draws low-pressure vapor from the evaporator and pushes high-pressure vapor into the high side; the metering device is the other divider at the opposite end of the cycle (Ch. 8, p. 128). In a scroll compressor, vapor pockets shrink as they move inward and are discharged through the port at the center of the scrolls (Ch. 9, p. 141). A screw compressor's slide valve unloader can stick in an unloaded position, bypassing vapor back to suction so the compressor runs without building discharge pressure (Ch. 25, p. 551). A crankcase heater prevents refrigerant from condensing in the compressor during the Off cycle (Ch. 43, p. 1045, Sec. 43.1).
Metering devices. Capillary tube systems do not use a liquid receiver; receivers are found on larger systems with low-side float or expansion valve metering (Ch. 12, p. 243). A system with a static (fanless) condenser needs a capillary tube about 10% longer than one with a fan-cooled condenser (Ch. 9, p. 144). A piston-type metering orifice allows free reverse flow when pressure lifts it off its seat and refrigerant passes through the flutes around the outside plus the center bore (Ch. 9, p. 146). Heat pumps often use two piston orifices: one meters in cooling and free-flows in heating, the…
Heating Systems
Key Concepts
Electric resistance heating. One watt = 3.413 Btu/hr, and 1 kW (1,000 W) = 3,413 Btu/hr (Ch. 35, p. 832; 20th ed. p. 1194). Electrical power is found with Watt's law, P = I × E. A sequencer closes and opens its contacts on a time delay to energize heating elements in sequence, typically about 30 seconds apart, to minimize the furnace's initial current draw and prevent disturbances such as flickering lights (Ch. 35, p. 834). A fusible link opens the circuit when temperature rises too high and cannot be reset — it must be replaced, and the cause investigated.
Baseboard controls. A line-voltage thermostat operates at 120 Vac or 240 Vac, is wired directly to the heater, and requires no step-down transformer; it is used primarily for electric baseboard resistance heaters (Ch. 35, p. 845, Sec. 35.5). A double-pole thermostat opens both legs of the 240 V circuit, reducing risk of grounds or shorts; a single-pole opens only one leg and is used less frequently (Ch. 35, p. 846).
Safety
Key Concepts
Fire hazards and extinguisher use - Electrical equipment fires (wiring, computers, switches, energized equipment) are Class C and require a nonconducting agent. Never use water on an electrical fire due to the high risk of electrical shock; only use a Class C–rated extinguisher — Ch. 2 Safety, p. 20 (Section 2.1.3) (20th ed.: Section 2.2.2 Fire Hazards). - Other classes: A ordinary combustibles (cooling/quenching), B flammable liquids, D combustible metals, K kitchen grease/fat/oil fires (Figure 2-4). - P.A.S.S.: Pull the pin, Aim at the base of the fire (not the flames), Squeeze the lever slowly, Sweep side to side until the fire is out (Ch. 2, "Using a Fire Extinguisher" procedure).
Refrigerant cylinder and pressure safety — p. 21 (20th ed.: Section 2.2.4 Pressure Hazards) - Refillable refrigerant cylinders: fill not more than 80%; liquid expands as temperature rises and can rupture a cylinder without sufficient vapor space. - Refillable cylinders must be inspected every five years; the next inspection date should be stamped on the cylinder. Dented, rusted or damaged cylinders must not be used. - Nitrogen purging of tubing during welding/brazing uses a low pressure of 1–2 psi. Commercial nitrogen cylinders hold approximately 2500 psi at room temperature, so a pressure regulator must always be used.