Tennessee BC-B, C Combined Commercial/Industrial Contractor

100 questions 300 minutes 73% to pass 14 topics 3:00 per question Open book
Try 10 free questions Free Cheat Sheet Official Bulletin

Practice at the real exam's pace

Every practice exam shows your time per question against the real exam's clock (3:00 here), and each topic lands in one of these:

Ready Find it faster Study it Needs both Rushing: slow down

What's on the exam

Questions per topic, out of 100
Estimating, Plan Reading15
General Code12
Sitework6
Footings and Foundations5
Concrete and Concrete Reinforcement16
Masonry10
Carpentry4
Interior Finish2
Structural Steel10
Roofing, Siding, and Insulation6
Plumbing Concepts4
HVAC Concepts2
Electrical Concepts2
OSHA Safety6

Topics

Open a topic to read its key concepts

Estimating, Plan Reading

15 on exam · 155 practice questions

TN BC-B, C Combined Commercial/Industrial Contractor — 15 questions (15%)

Key Concepts

Scales and drawing basics - Dimensions are shown in engineering scale (feet and tenths of a foot) or architectural scale (feet, inches, and fractions of an inch). Plans used in excavation and grading work are likely to use engineering scale (Module 22209, Section 1.0.0, Page 98). - Most utility site plans use two scales — one horizontal, one vertical. Usually the horizontal scale is ten times the vertical; in the text's example, 1" = 40' horizontal and 1" = 10' vertical gives a 4:1 ratio (Pipe & Excavation Contracting, Page 109). - Station numbers show horizontal distance in multiples of 100 feet: left of the plus =…

General Code

12 on exam · 59 practice questions

Key Concepts

Administration. A permit application is deemed abandoned 180 days after the date of filing, unless pursued in good faith or a permit has been issued (IBC 105.3.2).

Occupancy classification. A building or tenant space used for assembly purposes with an occupant load of less than 50 persons is classified as Group B (IBC 303.1.1).

Types of construction. Type III is construction in which the exterior walls are of noncombustible materials and the interior building elements are of any material permitted by the code (IBC 602.3). In Types I and II, wood nailers for parapet flashing and roof cants are permitted combustible materials (IBC 603.1, Item 27).

Sitework

6 on exam · 107 practice questions

Key Concepts

Excavation safety and soil classification (OSHA Subpart P) - Type A = cohesive soil with unconfined compressive strength 1.5 tsf or greater; Type B = greater than 0.5 tsf but less than 1.5 tsf; Type C = 0.5 tsf or less. Soil is not Type A if it is fissured, subject to vibration, or previously disturbed (29 CFR 1926, Subpart P, Appendix A, para. (b)). - Ventilation or other adequate precautions are required so employees are not exposed to a flammable gas concentration in excess of 20 percent of the lower flammable limit (§1926.651(g)(1)(iii)). Atmospheric testing is required before entry into excavations greater than 4 feet deep where oxygen deficiency (below 19.5 percent) or other hazardous atmospheres…

Footings and Foundations

5 on exam · 25 practice questions

Source: 2021 International Building Code, Chapters 16 and 18

Key Concepts

Lateral soil loads (Section 1610.1) - Foundation walls and retaining walls shall be designed to resist lateral soil loads from adjacent soil; Table 1610.1 values are the minimum design lateral soil loads unless determined otherwise by a geotechnical investigation per Section 1803. - Foundation walls and other walls in which horizontal movement is restricted at the top shall be designed for at-rest pressure. - Retaining walls free to move and rotate at the top are permitted to be designed for active pressure. - Exception: foundation walls extending not more than 8 feet below grade and laterally supported at the top by flexible diaphragms are permitted to be designed…

Concrete and Concrete Reinforcement

16 on exam · 198 practice questions

Tennessee BC-B, C Combined Commercial/Industrial Contractor — 16 questions (16%)

Key Concepts

IBC code minimums (plain and structural concrete) - Concrete floor slabs supported directly on the ground: thickness not less than 3½ inches (89 mm) — 2021 IBC §1907.1. A 6-mil polyethylene vapor retarder with joints lapped not less than 6 inches shall be placed between base course/subgrade and slab, or approved equivalent (§1907.1). - Plain concrete footings: for Group R-3 occupancies and buildings of other occupancies less than two stories above grade plane of light-frame construction, the required footing thickness of ACI 318 is permitted to be reduced to 6 inches (152 mm), provided the footing does not extend more than 4 inches (102 mm) on either…

Masonry

10 on exam · 101 practice questions

Key Concepts

Materials and standards - Building brick grades: Grade SW is highly resistant to frost action, for brick exposed to freezing weather such as foundation courses or retaining walls; MW for exposure below freezing where the brick is not likely to be permeated with water (face of a wall aboveground); NW for interior backup masonry (Modern Masonry 9th ed., p. 116). - A solid masonry unit is "one whose cross-sectional area in every plane parallel to the bearing surface is 75% or more of its gross cross-sectional area"; a hollow unit has less than 75% solid in any plane (p. 123). - Green bricks are bricks that have not been fired; they contain 5% to 30% moisture as…

Carpentry

4 on exam · 36 practice questions

Key Concepts

Dimensions - Where lumber dimensions are specified in Chapter 23, they are nominal dimensions unless specifically designated as actual (IBC 2301.2). - Computations to determine required member sizes shall be based on net dimensions (actual sizes), not nominal (IBC 2304.2).

Conventional light-frame limits (Section 2308.2) - Floor-to-floor height shall not exceed 11 feet, 7 inches; exterior bearing wall and interior braced wall heights shall not exceed a stud height of 10 feet (2308.2.2). - Average dead loads shall not exceed 15 psf for combined roof and ceiling, exterior walls, floors and partitions; floor live loads shall not exceed 40 psf; ground snow loads shall not exceed 50 psf (2308.2.3, Items 1–3). - Ceiling joist and rafter framing…

Interior Finish

2 on exam · 13 practice questions

Key Concepts

Gypsum board fastening — special ceiling cases - Type-X gypsum board on a garage ceiling beneath a habitable room: install perpendicular to the ceiling framing, fastened at a maximum 6 inches on center with minimum 1-5/8 inch 6d coated nails or equivalent drywall screws (IBC 2021, Chapter 25, Table 25.06.1). - Where a water-based texture is applied over framing at 24 inches on center, minimum board thickness increases from 1/2 inch to 5/8 inch; alternatively 1/2-inch sag-resistant gypsum ceiling board may be used, applied perpendicular to framing (IBC 2021, Chapter 25, Table 25.06.1 notes).

Structural Steel

10 on exam · 89 practice questions

Key Concepts

Site readiness before erection. The steel erector must receive written notification that concrete or mortar in footings, piers and walls has attained 75 percent of the intended minimum compressive design strength (based on an appropriate ASTM field-cured sample test) or sufficient strength to support the loads imposed during steel erection — 29 CFR 1926, Subpart R, §1926.752(a)(1) and (b).

Pre-erection planning. The owner's designated representative for design (ODRD) is responsible for job planning and works with the owner's designated representative for construction (ODRC), who answers to the owner for overall construction, quality and completion (Study Guide, Structural Ironworking Two, §2.3.1). Members must be identified and a competent person must determine the erection sequence before pick lists (also…

Roofing, Siding, and Insulation

6 on exam · 46 practice questions

Key Concepts

Roof covering slope and fire classification - Asphalt shingles shall only be used on roof slopes of 2 units vertical in 12 units horizontal (2:12) or greater. Slopes from 2:12 to less than 4:12 require double underlayment. (IBC 2021, Section 1507.2.2) - Type IIA construction requires a minimum Class B roof covering classification. (IBC 2021, Section 1505.1, Table 1505.1)

Flashing - Valley flashing for wood shingles shall extend not less than 11 inches from the centerline each way and shall have a splash diverter rib not less than 1 inch high at the flow line. (IBC 2021, Section 1507.8.8) - Flashing shall be installed at wall and roof intersections, at gutters, wherever there is a change in…

Plumbing Concepts

4 on exam · 20 practice questions

(Tennessee BC-B, C Combined Commercial/Industrial Contractor — 4 questions, 4% of exam)

The source material for this topic is IBC 2021 Chapter 29, Sections 2901–2903 (Minimum Plumbing Facilities and Installation of Fixtures). Everything below is drawn from that chapter; subtopics not addressed there are not covered here.

Key Concepts

Fixture counts and calculations - Plumbing fixtures shall be provided in the minimum number shown in Table 2902.1, based on the actual use of the building or space; uses not shown are considered individually by the code official (Section 2902.1). - To determine the occupant load of each sex, the total occupant load shall be divided in half; ratios are then applied per Table 2902.1. Fractional numbers shall be **rounded…

HVAC Concepts

2 on exam · 10 practice questions

Scope note: The verified questions and reference text supplied for this topic all come from one place — Chapter 28, Mechanical Systems, of the 2021 International Building Code, specifically Section 2801.1 Scope (pages 652–653). Chapter 28 does not itself spell out combustion air sizing, pipe sizing, vent types, duct insulation, condensate drains, relief valves or exhaust requirements; the IBC User note for Chapter 28 explains that the chapter "regulates such systems by linking to the International Mechanical Code® and International Fuel Gas Code®, where details of mechanical system requirements are provided." Your job on these questions is to know which code governs which activity — that is what every verified question asks.

Key Concepts

Electrical Concepts

2 on exam · 9 practice questions

The source material for this topic is IBC 2021, Chapter 27 (Electrical), Sections 2701 and 2702. All verified questions draw from Section 2702, Emergency and Standby Power Systems. Cover that material thoroughly.

Key Concepts

Scope (Section 2701.1). This chapter and NFPA 70 govern the design, construction, erection and installation of electrical components, appliances, equipment and systems. The International Fire Code, the International Property Maintenance Code and NFPA 70 govern use and maintenance. The International Existing Building Code and NFPA 70 govern alteration, repair, relocation, replacement and addition.

Stationary generators (2702.1.1). Stationary emergency and standby power generators required by the code shall be listed in accordance with UL 2200.

OSHA Safety

6 on exam · 39 practice questions

Key Concepts

Fall protection (Subpart M) - Each employee on a walking/working surface with an unprotected side or edge 6 feet or more above a lower level must be protected by guardrail, safety net, or personal fall arrest systems — §1926.501(b)(1). - Residential construction activities 6 feet or more above lower levels: guardrail systems, scaffolding, safety net system, or personal fall arrest system — §1926.501(b)(13). - Guardrail top rail must withstand, without failure, a force of at least 200 pounds (890 N) applied within 2 inches of the top edge in any outward or downward direction, at any point along the top edge — §1926.502(b)(3). Midrails and intermediate members: 150 pounds — §1926.502(b)(5). Top rail height 39–45 inches (1926.502).…

Final Practice Exam
100 questions · 300 min · timed simulation of the real exam
Never the same exam twice. Every attempt is drawn fresh from 907 questions, about 9 full exams' worth, and questions you haven't seen come first.
Business and Law exam included
11 topics · 50 questions · 150 min

Required Books

Open-book exam
OSHA Standards for the Construction Industry
Buy on Amazon
2021 Edition
International Building Code 2021
Buy on Amazon
2024 Edition
Study Guide for Commercial Building Contractor
Official source
2012 Edition
Study Guide for Structural Steel
Buy on Amazon
4th Edition
NASCLA Contractors Guide to Business, Law and Project Management – Tennessee
Buy on Amazon
9th Edition
Modern Masonry - Brick, Block, Stone
Buy on Amazon
Revised
Pipe and Excavation Contracting
Buy on Amazon
4th Edition
Technical Digest No. 9 – Handling and Erection of Steel Joists and Joist Girders
Buy on Amazon
SDI Manual of Construction with Steel Deck
Buy on Amazon
17th Edition
Design and Control of Concrete Mixtures
Buy on Amazon
Training and Certification of Field Personnel for Unbonded Post-Tensioning - Level 1 Field Fundamentals
Buy on Amazon
2nd (MNL-127-99, 1999)
Erectors' Manual – Standards and Guidelines for the Erection of PreCast Concrete Products
Buy on Amazon
ACI 530/530.1-11 or ACI 530/530.1-13 (2011 or 2013): Building Code Requirements and Specification for Masonry Structures
Buy on Amazon
ACI 318-11 or ACI 318-14: Building Code Requirements for Structural Concrete and Commentary
Buy on Amazon
10th (2022)
Placing Reinforcing Bars, Recommended Practices
Buy on Amazon
Carpentry and Building Construction
Buy on Amazon
As an Amazon Associate we earn from qualifying purchases.
$59.95/monthCancel anytime. Instant access.