North Carolina Electrical Contractor - Fire Alarm/Low Voltage (SP-FA/LV)

North Carolina Electrical Contractor - Fire Alarm/Low Voltage (SP-FA/LV) exam study guide: the bulletin's key facts, the official outline, the reference books and sample questions with answers.

50 questions 180 minutes 70% to pass 7 topics 3:36 per question Open book 268 questions in pool Bulletin: July 2026
Full practice exam $9.95
  • 50 questions on a 180-minute clock, like the real exam
  • Every answer explained; code questions cite the book and section so you can find it in your own copy
  • A fresh draw from 268 questions each attempt
Try 10 free questions
Study Course $59.95/month
  • Unlimited full exams, topic quizzes and study briefs
  • Cancel anytime
See the study course
Not sure which exam you need? Text us: (813) 582-5360
Texts preferred · 9am–9pm Central
On this page

North Carolina Electrical Contractor - Fire Alarm/Low Voltage (SP-FA/LV) Exam Study Guide

This guide covers what you need for the North Carolina Electrical Contractor - Fire Alarm/Low Voltage (SP-FA/LV) exam: the key facts from the official bulletin, the topics it tests, the reference books, sample questions with answers, and a plan to prepare. PSI gives the exam.

North Carolina Electrical Contractor - Fire Alarm/Low Voltage (SP-FA/LV) Exam at a Glance

Here are the exam's key facts from the official bulletin:

Questions 50 questions
Time limit 3 hours
Passing score 70% correct
Books in the exam room Open book
Exam fee $125

On exam day

  • Questions are multiple choice with four suggested answers and only one correct answer.
  • Two valid, non-expired signature-bearing IDs are required, one with a photograph, matching the name under which the candidate registered.
  • Candidates should arrive 30 minutes before the appointment time.
  • References must be softbound, spiral, or hardbound with no loose-leaf or partial books, must be candidate-supplied, may not be written in during the exam, and may not contain additional papers.
  • Highlighting, underlining and handwritten notes made before the exam are allowed (pencil notes must be highlighted), and only permanent tabs may be used.
  • Calculators are provided at the test center.
  • Scratch paper, pencils and calculators are provided, while notes, briefcases, backpacks, hats, cell phones, pagers and children are prohibited in the examination area.

References you may bring

  • National Electrical Code (2020 edition)
  • National Fire Alarm Code (2013 edition)
  • NASCLA Contractors Guide to Business, Law and Project Management: North Carolina Electrical Contractors' Edition (current edition)

Study references listed in the bulletin (not allowed in the exam room)

  • Electrical Contractors Licensing Law (General Statutes Chapter 87, Article 4)
  • The Board's Rules for the Implementation of the Electrical Contractors Licensing Law (Title 21, North Carolina Administrative Code, Chapter 18B)

Scheduling, changes and retakes

  • Candidates register for the examination by calling PSI at (855) 746-8173 or online at https://test-takers.psiexams.com/ncbeec.
  • Board approval is required before scheduling, and the approval allows one examination attempt within a 90-day authorization period.
  • Candidates who miss the appointment or arrive after the examination start time lose their examination fees and may be refused admission.
  • Results are given immediately at the test center, with a diagnostic report of strengths and weaknesses for candidates who do not pass.
  • A candidate who fails must wait 3 months before retaking the same classification and must re-apply to the Board for each attempt.
  • A passing candidate must complete a License Application with the Board to obtain and activate the license.

Source: NCBEEC Examination Information Handbook (North Carolina Board of Examiners of Electrical Contractors), July 2026. Check the bulletin before test day: fees and rules can change.

What the North Carolina Electrical Contractor - Fire Alarm/Low Voltage (SP-FA/LV) Exam Covers

The official content outline has 7 topics:

Topic Questions Share of the exam
Bonding and Grounding 4 8%
Wiring Methods and Terminations 9 18%
Boxes and Fittings 3 6%
Motors and Control Wiring 3 6%
Load Calculations 4 8%
General 6 12%
Laws, Rules, Basic Business Practices, and Practical Applications 21 42%

Bonding and Grounding: Systems and equipment requiring grounding and ground-fault protection; Location of connection and required interconnections; Conductor identification and color coding; Bonding jumpers; Equipment grounding conductors; Low-voltage specifications; Bonding conductor connections; Termination.
Wiring Methods and Terminations: Permitted applications and usages; Characteristics; Conduit and wireway fill; Permitted applications and usages; Characteristics; Protection from damage; Traveling cables and controls; Permitted usages and ampacity ratings.
Boxes and Fittings: General information; Sizing requirements.
Motors and Control Wiring: General information; Separation of conductors.
Load Calculations: Conductor ampacity requirements; Low-voltage.
General: Definitions; Installation requirements.
Laws, Rules, Basic Business Practices, and Practical Applications: Electrical Contractors Licensing Law (General Statutes Chapter 87, Article 4); Board’s Rules for the Implementation of the Electrical Contractors Licensing Law (Title 21, North Carolina Administrative Code, Chapter 18B); NASCLA Contractors’ Guide to Business, Law and Project Management - North Carolina Electrical Edition; National Fire Alarm Code.

How to Prepare for the North Carolina Electrical Contractor - Fire Alarm/Low Voltage (SP-FA/LV) Exam

Start with the books. This is an open-book exam, so the references on the bulletin's list are your main study tool. Get the editions the bulletin names.

Learn where things are. Read the table of contents and the index of each book until you know where every major subject lives. On test day, finding an answer fast matters more than memorizing it.

Highlight the sections you use most. The exam facts above list the bulletin's rules on tabs and markings, so follow them exactly.

Spend most of your time on the biggest topics. Laws, Rules, Basic Business Practices, and Practical Applications and Wiring Methods and Terminations make up 60% of the exam.

Take timed practice exams. The clock trains you to find answers at the pace the real exam needs: about 3 minutes 36 seconds per question.

Aim to pass more than once. One passing score can be luck. Several in a row means you're ready.

Reference Books for the North Carolina Electrical Contractor - Fire Alarm/Low Voltage (SP-FA/LV) Exam

SP-FA/LV candidates must bring the 2020 National Electrical Code, the 2013 National Fire Alarm Code and the current NASCLA Contractors Guide, and the exam also covers the Licensing Law and the Board's Rules as study material.

Where to get them:

On Test Day

  • Go through the whole exam first. Answer every question you know and bookmark the ones you don't. Every exam lets you come back to bookmarked questions.
  • Then go back to your bookmarks and work them out.
  • Don't let one question eat your time. You have 3 hours for 50 questions, which is about 3 minutes 36 seconds per question.
  • Before you finish, answer anything you skipped. A blank can't earn a point.

Study Tips

On an open-book exam, the winners aren't the smartest people in the room — they're the fastest at finding answers. Buy the required book, practice with it open, and tab and highlight each section the first time a question sends you there. Learn the index and table of contents until you can land on any topic in seconds. That speed is what separates a pass from a fail.

On an open-book exam, work through every question once: answer the ones you know and skip the ones you don't. Then go back to the ones you flagged. You can bookmark questions for later review, just like on our exams — and don't sink too much time into any single question. The clock is still running.

Give yourself at least three to six weeks. Use your exam's candidate bulletin as your roadmap for what's tested, and spend your time on finding-it-fast skills over rote memorization. In practice, aim for three clean passes at 80% or higher — setting your practice bar above the real cut score gives you a comfortable margin on test day.

Practicing against a ticking clock is the best way to beat exam-clock anxiety. Use these timed tests to build your pacing, so you learn to move steadily and never burn too long on a single question. By test day, the format feels routine.

Sample North Carolina Electrical Contractor - Fire Alarm/Low Voltage (SP-FA/LV) Practice Questions

These questions come from our practice question bank, each with its answer and reference.

Sample 1 — Bonding and Grounding

Question: A metal underground water pipe must be in direct contact with the earth for what minimum distance to qualify as a grounding electrode?

  • A. 5 ft
  • B. 20 ft
  • C. 8 ft
  • D. 10 ft

Correct Answer: D

Per NEC 250.52(A)(1), a metal underground water pipe in direct contact with the earth for 10 ft or more (including any metal well casing bonded to the pipe) is permitted as a grounding electrode.

Reference: NEC 2020 Section 250.52(A)(1)

Sample 2 — Load Calculations

Question: You are installing a conduit run on a rooftop for a commercial HVAC system. The conduit is mounted directly on the roof surface with less than 23 mm (7/8 in.) clearance above the roof. The outdoor temperature is 40°C (104°F). What ambient temperature must you use to apply correction factors from the ampacity tables?

  • A. 40°C (104°F)
  • B. 53°C (127°F)
  • C. 63°C (145°F)
  • D. 73°C (164°F)

Correct Answer: D

Per NEC 310.15(B)(2), for raceways or cables exposed to direct sunlight on or above rooftops where the distance above the roof is less than 23 mm (7/8 in.), a temperature adder of 33°C (60°F) shall be added to the outdoor temperature. 40°C + 33°C = 73°C (104°F + 60°F = 164°F).

Reference: NEC 2020 Section 310.15(B)(2)

Sample 3 — Boxes and Fittings

Question: When boxes and conduit bodies are installed in damp or wet locations, what size range of drainage openings is permitted to be installed in the field?

  • A. Not smaller than 10 mm (3/8 in.) and not larger than 16 mm (5/8 in.)
  • B. Not smaller than 1 mm (1/32 in.) and not larger than 3 mm (1/8 in.)
  • C. Not smaller than 6 mm (1/4 in.) and not larger than 13 mm (1/2 in.)
  • D. Not smaller than 3 mm (1/8 in.) and not larger than 6 mm (1/4 in.)

Correct Answer: D

Per NEC 314.15, approved drainage openings not smaller than 3 mm (1/8 in.) and not larger than 6 mm (1/4 in.) in diameter shall be permitted to be installed in the field in boxes or conduit bodies listed for use in damp or wet locations.

Reference: NEC 2020 Section 314.15

Sample 4 — Motors and Control Wiring

Question: According to the NEC, the accessible portion of abandoned Class 2, Class 3, and ______ cables shall be removed.

  • A. NM
  • B. MC
  • C. PLTC
  • D. THHN

Correct Answer: C

Per NEC 725.25, the accessible portion of abandoned Class 2, Class 3, and PLTC cables shall be removed. Where cables are identified for future use with a tag, the tag shall be of sufficient durability to withstand the environment involved. This requirement helps prevent the accumulation of combustible cable material in building spaces, which is an important fire safety consideration.

Reference: NEC 2020 Section 725.25

Why Practice Online Instead of With a PDF

A PDF shows you questions. It doesn't show you the clock. Our practice exams are timed and on a screen, so you practice finding answers under time pressure, not just reading them. Each attempt draws a new set of questions from our bank, and your results break the score down by outline topic so you know what to study next.

Start Practicing

Take the free North Carolina Electrical Contractor - Fire Alarm/Low Voltage (SP-FA/LV) practice exam to see where you stand, then work through the topics that need attention. For the official rules, read the exam bulletin, and see the licensing board's website.

Frequently Asked Questions

How many questions are on the SP-FA/LV exam and how long do I have?
The Fire Alarm/Low Voltage (SP-FA/LV) exam consists of 50 multiple-choice questions, and you have a maximum of 3 hours to complete it.
What score do I need to pass the SP-FA/LV exam?
You must correctly answer at least 70% of the questions to pass. The passing score applies to all license classifications administered by the Board.
What is the exam fee for the SP-FA/LV license, and how do I pay?
The exam application and fee is $125, paid to the Board (NCBEEC) when you submit your application. Payment may be made by check, money order, or credit card made payable to NCBEEC.
What reference books can I bring to the SP-FA/LV exam?
You must bring three references: the 2020 National Electrical Code, the 2013 National Fire Alarm Code (NFPA 72), and the NASCLA Contractors Guide to Business, Law and Project Management (current edition). Those three are the only references allowed in the testing center; no other books or materials are permitted.
Is the SP-FA/LV exam open book?
Yes, the exam is open book. You bring your own copies of the approved references—the 2020 NEC, the 2013 NFPA 72, and the NASCLA Contractors Guide—and may use them during the exam. No other references are allowed.
How do I register for the SP-FA/LV exam after getting approved?
After the Board approves your application, PSI will email your Test Taker ID within 48–72 hours of the start of the authorization period listed on your approval letter. You can then schedule your exam online at the PSI website or by calling PSI at (855) 746-8173. You must take the exam within 90 days of approval.
What happens if I fail the SP-FA/LV exam? When can I retake it?
If you fail, you must wait 3 months from the date of the failed exam before you are eligible to take it again in the same classification. Each new attempt requires a new application and a new $125 exam fee submitted to the Board.
Can I review my failed SP-FA/LV exam, and is there a fee?
Yes, you may review your failed exam once. You submit an Examination Review Request Form to the Board along with a $25 review fee. Reviews are supervised by the Board or staff and are held in group sessions (approximately 4 hours) or individually if needed.
What experience do I need to qualify for the SP-FA/LV exam?
You must have at least 3,000 total hours of experience, of which at least 2,000 hours must be primary experience. Time actually spent installing or maintaining fire alarm/low voltage systems counts as primary experience, and FA/LV applicants may also receive credit for experience in any Rule .0202 capacity gained in the low voltage field.
What work is a holder of the SP-FA/LV license authorized to perform, and is there a project dollar limit?
The SP-FA/LV license authorizes installation, maintenance, or repair of low voltage wiring and directly related wiring: systems of 50 volts or less, Class 2 and Class 3 power-limited systems, paging systems not over 70 volts, fire alarm and burglar alarm systems, and certain line-voltage wiring not over 300 volts to ground starting at the load side of a disconnect or junction box installed by others (not in hazardous locations). There is no dollar limit on projects for special restricted licensees—the project value caps that apply to Limited and Intermediate licenses do not apply to the SP-FA/LV license.