How to Pass the Wyoming Low-voltage General Technician (ICC 218, 2023 NEC) Exam
You don't have to guess how to prepare for the Wyoming Low-voltage General Technician (ICC 218, 2023 NEC) exam. This guide lays it out: the key facts from the official bulletin, the topics on the test, the books you need, sample questions with answers, and a study plan you can follow. Pearson VUE gives the exam.
Wyoming Low-voltage General Technician (ICC 218, 2023 NEC) Exam Basics
Here's what the official bulletin says about the exam:
| Questions | 50 questions |
| Time limit | 3 hours |
| Passing score | a minimum score of 75 |
| Books in the exam room | Open book |
| Exam fee | $115 |
On exam day
- The exam uses four-option multiple-choice questions with one correct answer.
- In addition to the NEC, candidates may use Ferm's Fast Finder Index, Ugly's Electrical Reference, the NEC Handbook (hardcover) and Tom Henry's Key Word Index during the exam, with the exam based only on the code provisions.
Scheduling, changes and retakes
- Exams are scheduled through PearsonVUE at www.pearsonvue.com/ICC.
- Candidates must first apply to the Department of Fire Prevention and Electrical Safety and receive approval before scheduling, and should wait 24-48 hours after the approval notice before scheduling.
- Results for examinations taken electronically are available immediately after the exam is completed.
- A failed exam may not be retaken until 10 days have passed.
- After passing, the candidate must contact the licensing jurisdiction for any other requirements needed to become licensed.
Source: Wyoming Electrical Contractor/Trades Examination Information Bulletin, PUBLISHED August 19, 2025. Check the bulletin before test day: fees and rules can change.
What's on the Wyoming Low-voltage General Technician (ICC 218, 2023 NEC) Exam
The official content outline splits the exam into 5 topics:
| Topic | Questions | Share of the exam |
|---|---|---|
| General Knowledge | 12 | 24% |
| Low-voltage Remote Control and Alarm Systems | 11 | 22% |
| Low-voltage Communication and Sound Systems | 18 | 36% |
| Low-voltage Control Circuits | 7 | 14% |
| Fiber Optical Cables and Raceways | 2 | 4% |
Your Wyoming Low-voltage General Technician (ICC 218, 2023 NEC) Study Plan
Your books are your best friend on this exam. It's open book, so the references on the bulletin's list are what you'll use on test day. Get your own copies in the editions the bulletin names.
Get to know them early. Spend time with each book's table of contents and index until you can find any major subject quickly. On an open-book exam, finding answers fast is the skill that counts.
Make the books yours. Highlight the sections you keep coming back to. The exam facts above list the bulletin's rules on tabs and markings, so follow them exactly.
Put your energy where the points are. Low-voltage Communication and Sound Systems and General Knowledge make up 60% of the exam, so start there.
Practice with the clock running. Our timed practice exams help you build the pace the real exam needs: about 3 minutes 36 seconds per question. Every attempt is another rep.
Keep going until you pass practice exams consistently. One good score is a great start. A few passing scores in a row is how you know you're ready.
Books You'll Need for the Wyoming Low-voltage General Technician (ICC 218, 2023 NEC) Exam
Where to get them:
Test Day Tips
Start with a quick pass through the whole exam. Answer every question you're sure about and bookmark the rest. Every exam lets you return to bookmarked questions, so nothing is lost by moving on. One catch: some exams lock the questions you've already seen once you take a break, so clear your bookmarks before any break.
Then come back to your bookmarks and work through them one at a time. Keep an eye on the clock: you have 3 hours for 50 questions, which is about 3 minutes 36 seconds per question. Before you finish, make sure every question has an answer. A blank can't earn a point.
Study Tips
Take this practice exam several times. The goal is to consistently clear your exam's passing score — often around 70–75% — so passing feels routine before you walk into the real test.
Only select answers that directly respond to the question asked—not ones that merely sound correct or seem true. After choosing, verify your answer against the question to confirm you didn't misread it and that your selection genuinely addresses what was asked.
Our practice exam is specifically designed to mimic the testing conditions at all exam centers. While untimed PDF study guides might help with studying, they don’t prepare you for the challenge of managing your time during an actual test.
Give yourself at least three to six weeks. Use your exam's candidate bulletin as your roadmap for what's tested, and spend your time on finding-it-fast skills over rote memorization. In practice, aim for three clean passes at 80% or higher — setting your practice bar above the real cut score gives you a comfortable margin on test day.
Know your way around each book's index and table of contents. Open-book exams reward speed: you need to find specific items quickly.
Try These Wyoming Low-voltage General Technician (ICC 218, 2023 NEC) Practice Questions
Give these a try. They come from our practice question bank, each with its answer and reference.
Sample 1 — Low-voltage Control Circuits
Question: Each motor is normally required to have an individual motor controller. For motors rated 1000 volts or less, under which condition is a single motor controller permitted to serve an entire group of motors?
- A. All motors in the group are supplied by one feeder
- B. The motors are in one room within sight of the controller
- C. All motors in the group are rated 2 hp or less
- D. Each motor in the group has individual overload protection
Correct Answer: B
NEC 2023, Section 430.87 Exception No. 1 permits a single motor controller, rated at not less than the equivalent horsepower of all motors in the group, where the motors drive several parts of a single machine, where the group is protected by one overcurrent device per 430.53(A), or where the group of motors is located in a single room within sight from the motor controller location.
Reference: NEC 2023 Section 430.87 Exception No. 1
Sample 2 — Fiber Optical Cables and Raceways
Question: The design drawings call for Type OFNR optical fiber cable, which the supplier cannot deliver. Which listed cable type is a permitted substitution for OFNR?
- A. OFNP
- B. OFCP
- C. OFNG
- D. OFCR
Correct Answer: A
Per NEC 2023, Table 770.154(b), the only permitted substitution for Type OFNR is Type OFNP. Conductive types (OFCR, OFCP) and general-purpose types (OFNG) may not be substituted for a nonconductive riser cable.
Reference: NEC 2023 Table 770.154(b)
Sample 3 — Low-voltage Communication and Sound Systems
Question: A premises-powered broadband network terminal is served by nonconductive optical fiber cable, and all circuits terminating at the terminal remain entirely inside the building. The coaxial cable shield has been separately grounded by a fixed connection to an equipment grounding conductor. For the connection to the network terminal grounding connection, which method is permitted?
- A. A listed device that retains the ground if the terminal is unplugged
- B. A bonding jumper to the intersystem bonding termination
- C. A grounding electrode conductor run to a driven ground rod
- D. A cord-and-plug connection
Correct Answer: D
NEC 2023, 840.101(C) provides that the network terminal is not required to be grounded unless required by its listing, and where the coaxial cable shield is separately grounded as described in 840.101(A)(1) or (A)(2), the use of a cord and plug for the connection to the network terminal grounding connection is permitted.
Reference: NEC 2023 Section 840.101(C)
Sample 4 — General Knowledge
Question: You are routing low-voltage cable and a small junction box in an exposed area beneath a metal-corrugated sheet roof deck in a warehouse. Measured from the lowest surface of the roof decking to the top of the cable, raceway, or box, what minimum spacing must be maintained?
- A. 3 in.
- B. 1 1/4 in.
- C. 2 in.
- D. 1 1/2 in.
Correct Answer: D
NEC 2023, 300.4(E) requires a cable, raceway, or box installed under metal-corrugated sheet roof decking to be installed and supported so there is not less than 38 mm (1 1/2 in.) measured from the lowest surface of the roof decking to the top of the cable, raceway, or box; installation in concealed locations in such decking is prohibited. The 1 1/4 in. figure applies to bored holes and framing-member clearance in 300.4(A) and (D); the 2 in. figure is the concrete slab thickness in the exception to 300.4(E).
Reference: NEC 2023 Section 300.4(E)
Why Practice Online?
Reading questions in a PDF is a start, but it doesn't prepare you for the clock. Our practice exams are timed and on a screen, so you build speed along with knowledge. Each attempt draws a new set of questions from our bank, and your results show your score by topic so you know where to focus next.
Ready to Start?