ICC G21 Low-Voltage Electrician Exam (2017 NEC) Practice Exam

50 questions 180 minutes 70% to pass 5 topics 3:36 per question Open book 219 questions in pool
Free Cheat Sheet Official Bulletin
Free

Free Practice Exam

$0

Test your knowledge with 10 questions from our pool of 20 free questions.

  • 10 questions per attempt
  • 30 minute time limit
  • Unlimited attempts
  • A new mix each time
  • Instant results
No account required.
Full Exam

Full Practice Exam

$9.95

Complete exam simulation matching the real Pearson VUE test format.

  • 50 questions (same as real exam)
  • 180 minute time limit
  • 5 topic areas covered
  • 219 questions in pool
  • Detailed explanations
Price per attempt. Never the same exam twice: each attempt draws a fresh set of questions.
Not sure which exam you need? Text us: (813) 582-5360
Texts preferred · 9am–9pm Central
Want a guided study plan? Study Course: topic briefs, 5 topic quizzes and this full exam. $59.95/month.
See the study course

ICC G21 Low-Voltage Electrician (2017 NEC) Practice Exam Guide

Built from the official Pearson VUE exam bulletin. View the bulletin

What's on the exam

Questions per topic, out of 50
LV Communications & Sound18
General Knowledge12
LV Remote Control & Alarm Systems11
LV Control Circuits7
Fiber Optical2

This practice exam is laid out like the official content outline for the ICC G21 Low-Voltage Electrician (2017 NEC) exam: General Knowledge, LV Remote Control & Alarm Systems, LV Communications & Sound, LV Control Circuits, Fiber Optical.

Two ways to practice: the free practice exam gives you 10 questions per attempt, as often as you want. The full practice exam gives you 50 questions on a 3 hours clock, with a new draw from our question bank every time.

5 topics

General Knowledge 12 items

Our study plan for this topic: Ohm's Law and power formulas (P, E, I, R relationships); Series, parallel, and combination circuit calculations; AC circuit concepts: impedance, reactance, inductance, and capacitance; Electrical formulas for amperes, kilowatts, kVA, and horsepower (single-phase and three-phase); Grounding and bonding principles and terminology (NEC Article 250); NEC code structure, scope, definitions, and general installation requirements; Power factor, power factor correction, and efficiency calculations; Electrical symbols, field terms vs. NEC terms, and units of measurement/conversion.

LV Remote Control & Alarm Systems 11 items

Our study plan for this topic: Class 1 vs. Class 2 vs. Class 3 circuit classifications and definitions; Power source requirements for Class 2 and Class 3 circuits; Class 1 circuit overcurrent protection and conductor sizing; Separation of Class 2/Class 3 circuits from power and Class 1 conductors; Cable types and substitution hierarchy for Class 2, Class 3, and PLTC cables; Fire alarm circuit classifications: NPLFA vs. PLFA; Power source and branch circuit requirements for fire alarm systems; Fire alarm cable types, listing requirements, and installation by building location.

LV Communications & Sound 18 items

Our study plan for this topic: Communications cable types and listing requirements (CMP, CMR, CMG, CM, CMX, CMUC); Cable installation locations — plenums, risers, and general-purpose spaces (Article 800); Grounding and bonding of communications cables and primary protectors (Article 800); Primary and secondary protectors — application, location, and types; CATV coaxial cable types, installation, and grounding of outer conductive shield (Article 820); Network-powered broadband communications systems — power classifications, cable types, and installation (Article 830); Audio signal processing and reproduction equipment — wiring methods, grounding, and loudspeaker installation (Article 640); Radio and television antenna systems — materials, clearances, discharge units, and bonding conductors (Article 810).

LV Control Circuits 7 items

Our study plan for this topic: Motor control circuit overcurrent protection and conductor sizing (NEC 430.72); Electrical arrangement and grounding of control circuits (NEC 430.74); Disconnection of motor control circuits from all power sources (NEC 430.75); Class 1 vs. Class 2 vs. Class 3 remote-control circuit classifications and power source requirements; Three-wire stop-start station wiring and seal-in contact operation; Multiple stop-start stations and hand-off-automatic (HOA) control circuit configurations; Jogging circuits and control relay wiring for inching operations; Control circuit transformer protection and reduced-voltage control wiring methods.

Fiber Optical 2 items

Our study plan for this topic: Optical fiber cable types and listing requirements (OFNP, OFCP, OFNR, OFCR, OFNG, OFCG, OFN, OFC); Installation locations within buildings (plenums, risers, general spaces, cable trays); Grounding and bonding of metallic members of optical fiber cables; Separation requirements when installed with electrical conductors; Overhead and underground optical fiber cables entering buildings; Cable substitution hierarchy for optical fiber cable types; Abandoned optical fiber cable requirements and fire spread prevention; Unlisted optical fiber cables entering buildings (50 ft rule, raceway requirements).

3 questions

Sample 1 — LV Communications & Sound

Question: You are installing Type CMX communications cable less than 6 mm (0.25 in.) in diameter in a multifamily apartment building, in building locations other than ducts, plenums, risers, cable trays, and distributing frames. Where is this cable permitted?

  • A. In concealed spaces behind finished walls
  • B. In plenum cable routing assemblies
  • C. In nonconcealed spaces
  • D. In riser shafts penetrating floors

Correct Answer: C

NEC 800.113(K)(2) permits Type CMX cables less than 6 mm (0.25 in.) in diameter in multifamily dwellings only in nonconcealed spaces. Risers, plenum assemblies, and concealed spaces require higher-rated cable types such as CM, CMG, CMR, or CMP.

Reference: NEC 2017 Section 800.113(K)

Sample 2 — General Knowledge

Question: What is the minimum burial depth (cover) required for rigid metal conduit installed underground in most locations?

  • A. 6 inches
  • B. 12 inches
  • C. 18 inches
  • D. 24 inches

Correct Answer: A

Per NEC Table 300.5, rigid metal conduit requires a minimum cover of 6 inches for most locations. This is less than direct burial cables (24 inches) or rigid nonmetallic conduit without concrete encasement (18 inches).

Reference: NEC 2017 Section 300.5

Sample 3 — LV Remote Control & Alarm Systems

Question: Which cable type is a permitted substitution for Type FPL power-limited fire alarm cable?

  • A. CL3P
  • B. PLTC
  • C. NPLF
  • D. FPLR

Correct Answer: D

Table 760.154(A) permits Types CMP, FPLP, CMR, FPLR, CMG, and CM as substitutions for Type FPL. Non–power-limited (NPLF), power-limited tray cable (PLTC), and Class 3 plenum (CL3P) cables are not listed substitutions for fire alarm FPL cable.

Reference: NEC 2017 Table 760.154(A)

Your first attempt is an inspection, not a final grade. The results page breaks your score down by outline topic, so you can see which areas need work. Compare it with the real exam's passing score, 70% correct, and keep practicing until you pass consistently.

  • Answer what you know first and bookmark the rest. Our practice exams let you bookmark and come back.
  • Work your bookmarks on the second pass.
  • Keep your pace. The real exam works out to about 3 minutes 36 seconds per question.
  • After each attempt, look up each missed question's reference in your book and read the section.

Questions 50 questions
Time limit 3 hours
Passing score 70% correct
Books in the exam room Open book
Exam fee $120
  • Results for examinations taken electronically are available immediately after the examination is completed.
  • You must wait 10 days before retaking a failed exam.

Source: National Contractor/Trades Examination Information Bulletin, PUBLISHED June 30, 2026; ICC Exam Catalog, checked September 27, 2026. Check the bulletin before test day: fees and rules can change.

Reference books

2 books on the bulletin
As an Amazon Associate we earn from qualifying purchases.
10 free questions30 min · no account