Kansas Master Plumber with Gas (ICC KGF, 2018 IPC/IFGC) Practice Exam Guide
What's on the exam
Questions per topic, out of 100This practice exam is laid out like the official content outline for the Kansas Master Plumber with Gas (ICC KGF, 2018 IPC/IFGC) exam: Administration General Regulations, Plumbing Fixtures, Water Supply and Distribution, Sanitary Drainage, Plumbing Vent Requirements, Traps, Interceptors, and Separators, Storm Drainage, Gas Piping.
Two ways to practice: the free practice exam gives you 10 questions per attempt, as often as you want. The full practice exam gives you 100 questions on a 4 hours clock, with a new draw from our question bank every time.
Administration General Regulations 36 items
Our study plan for this topic: General Installation Requirements; Code Definitions and Terms; Plan Reading; Testing; Materials; Permits and permit applications; Inspections and inspection types; Code official authority and duties.
Plumbing Fixtures 13 items
Our study plan for this topic: Water Heaters; Water Closets and Urinals; Specialty Fixtures; Bathtubs, Showers, Sinks, and Lavatories; Minimum Number of Required Plumbing Fixtures by Occupancy; Fixture Installation Requirements and Clearances; Faucets, Fixture Fittings, and Shower Valve Standards; Flushing Devices for Water Closets and Urinals.
Water Supply and Distribution 9 items
Our study plan for this topic: Service Distribution and Piping; Water Supply and Pressure; Protection of Potable Water Supply; Pipe Materials and Approved Standards for Water Service and Distribution; Joining Methods and Connection Requirements by Pipe Material; Fixture Supply Pipe Sizing and Flow Rate Requirements; Hot Water Supply System Requirements and Temperature Controls; Valve Installation Requirements and Locations.
Sanitary Drainage 8 items
Our study plan for this topic: Building Sanitary Drainage; Sumps and Ejectors; Indirect and Special Waste Systems; Drainage pipe materials and applicable standards (above-ground, underground, and building sewer); Pipe joints and connection methods by material type; Slope, sizing, and fixture unit load calculations for drainage systems; Cleanout requirements, placement, spacing, and access; Drainage fittings, changes in direction, and prohibited connections.
Plumbing Vent Requirements 6 items
Our study plan for this topic: Vent Connections and Grades; Vent Terminals; Vent Pipe Sizing and Developed Length; Types of Venting Methods (Individual, Common, Wet, Circuit, Combination, Island, Single-Stack); Air Admittance Valves; Trap Seal Protection and Fixture Trap Distance from Vent; Vent Stack and Stack Vent Requirements; Relief Vents for Multi-Story Stacks.
Traps, Interceptors, and Separators 5 items
Our study plan for this topic: Installation of Traps; Interceptors and Separators; Trap seal depth requirements and protection methods; Prohibited trap types; Trap sizing and dimensional limits; Grease interceptor sizing and capacity requirements; Oil separator design and capacity requirements; Sand interceptors and specialty interceptors (clothes washers, bottling, slaughterhouses).
Storm Drainage 2 items
Our study plan for this topic: Storm Drainage; Sizing of vertical conductors, leaders, and horizontal storm drains using 100-year rainfall rate tables; Primary and secondary (emergency overflow) roof drain requirements and scupper sizing; Prohibited connections and disposal requirements for storm water; Approved materials for inside conductors, underground storm drain pipe, building storm sewer pipe, and subsoil drain pipe; Roof drain installation requirements and flow rate calculations for system sizing; Storm drain traps: when required, sizing, material, and cleanout requirements; Siphonic roof drainage system design standards.
Gas Piping 21 items
Our study plan for this topic: Gas Piping for Service & Distribution Piping; Gas Piping Requirements, Specific Appliances Equipment; Source of Combustion Air & Duct Openings; Fuel-burning Appliance, Vent, Connector; CSST bonding and grounding requirements; Pipe sizing methods and sizing tables (longest length, branch length, hybrid pressure); Permitted piping materials, tubing standards, and fitting types; Pressure testing procedures, test medium, duration, and leak detection.
Sample 1 — Administration General Regulations
Question: There is insufficient evidence that a proposed piping product conforms to the plumbing code, so the code official requires tests as evidence of compliance. Such tests shall be performed by:
- A. A registered design professional
- B. The code official or a deputy
- C. The permit holder
- D. An approved agency
Correct Answer: D
Per IPC 105.3.2, tests required under 105.3 shall be performed by an approved agency, and under 105.3 they are made at no expense to the jurisdiction. The permit holder makes the plumbing system tests required by 312/107.4, which is a different requirement.
Reference: IPC 2018 Chapter 1 — Sections 105.3 and 105.3.2 Required Testing/Testing Agency
Sample 2 — Gas Piping
Question: On a residential project you run a single underground branch that serves only a permanently piped outdoor grill and outdoor gas lights. The route is approved by the code official and is in a location not susceptible to physical damage. What is the minimum depth below finished grade for this line?
- A. 12 inches
- B. 24 inches
- C. 18 inches
- D. 8 inches
Correct Answer: D
IFGC 404.12 sets a general minimum burial depth of 12 inches for underground piping, but 404.12.1 permits individual lines to outdoor lights, grills and similar appliances to be installed not less than 8 inches below finished grade where the installation is approved and is in a location not susceptible to physical damage.
Reference: IFGC 2018 Sections 404.12 and 404.12.1
Sample 3 — Plumbing Fixtures
Question: A school toilet room is served by a circular group wash-up fixture providing 60 inches of usable rim space. For purposes of meeting the minimum required number of fixtures, how many lavatories does this group wash-up fixture represent?
- A. 5
- B. 4
- C. 3
- D. 2
Correct Answer: C
Per IPC 2018 Section 419.1, every 20 inches of rim space is considered as one lavatory. 60 inches ÷ 20 inches = 3 lavatories. Group wash-up equipment must also conform to the material requirements of Section 402.
Reference: IPC 2018 Chapter 4, Section 419.1 (Lavatories — Approval/Rim Space)
Your first attempt is an inspection, not a final grade. The results page breaks your score down by outline topic, so you can see which areas need work. Compare it with the real exam's passing score, a minimum score of 75, and keep practicing until you pass consistently.
- Answer what you know first and bookmark the rest. Our practice exams let you bookmark and come back.
- Work your bookmarks on the second pass.
- Keep your pace. The real exam works out to about 2 minutes 24 seconds per question.
- After each attempt, look up each missed question's reference in your book and read the section.
| Questions | 100 questions |
| Time limit | 4 hours |
| Passing score | a minimum score of 75 |
| Books in the exam room | Open book |
| Exam fee | $115 |
- Results for examinations taken electronically are available immediately after completion of the examination.
- You must wait 10 days before retaking a failed exam.
Source: State of Kansas Contractor/Trades Examination Information Bulletin, PUBLISHED August 20, 2026 (page headers read "December 9, 2025"). Check the bulletin before test day: fees and rules can change.