Alabama · Prov

Alabama NASCLA Journey-level Electrician Exam Practice Exam

100 questions 300 minutes 75% to pass 10 topics 3:00 per question Open book 493 questions in pool
Free Cheat Sheet Official Bulletin
Free

Free Practice Exam

$0

Test your knowledge with 10 questions from our pool of 20 free questions.

  • 10 questions per attempt
  • 30 minute time limit
  • Unlimited attempts
  • A new mix each time
  • Instant results
No account required.
Full Exam

Full Practice Exam

$9.95

Complete exam simulation matching the real Prov test format.

  • 100 questions (same as real exam)
  • 300 minute time limit
  • 10 topic areas covered
  • 493 questions in pool
  • Detailed explanations
Price per attempt. Never the same exam twice: each attempt draws a fresh set of questions.
Not sure which exam you need? Text us: (813) 582-5360
Texts preferred · 9am–9pm Central
Want a guided study plan? Study Course: topic briefs, 10 topic quizzes and this full exam. $59.95/month.
See the study course

Alabama NASCLA Journey-level Electrician Practice Exam Guide

Built from the official Prov exam bulletin. View the bulletin

What's on the exam

Questions per topic, out of 100
Wiring and Protection18
Selects and Installs Cabinets, Boxes, Fittings, Conduit16
General Code Requirements15
Electrical Theory and Principles10
Equipment for General Use10
Basic Electrical Safety8
Special Occupancies and Special Equipment8
Testing and Troubleshooting7
Interpreting Plans & Specifications6
Special Conditions and Communication Systems2

This practice exam is laid out like the official content outline for the Alabama NASCLA Journey-level Electrician exam: Interpreting Plans & Specifications, Basic Electrical Safety, Electrical Theory and Principles, Testing and Troubleshooting, General Code Requirements, Wiring and Protection, Selects and Installs Cabinets, Boxes, Fittings, Conduit, Equipment for General Use, Special Occupancies and Special Equipment, Special Conditions and Communication Systems.

Two ways to practice: the free practice exam gives you 10 questions per attempt, as often as you want. The full practice exam gives you 100 questions on a 5 hours clock, with a new draw from our question bank every time.

10 topics

Interpreting Plans & Specifications 6 items

Our study plan for this topic: Electrical symbols for outlets, switches, and lighting fixtures; Electrical symbols for wiring, connections, and panel components; NEMA configuration wiring diagrams and receptacle identification; Miscellaneous wiring diagrams for three-way and four-way switch circuits; Metric designator and trade sizes for conduit; U.S. and metric unit conversions for linear, area, and weight measurements; Decimal and fraction equivalents for measurements; Electrical Symbols.

Basic Electrical Safety 8 items

Our study plan for this topic: Electrical hazards: shock, electrocution, arc flash, and arc blast; Lockout/tagout procedures and establishing an electrically safe work condition; Arc flash risk assessment and shock risk assessment; Shock protection boundaries: limited approach and restricted approach; Personal protective equipment selection and arc flash PPE categories; Energized electrical work permits; Employer and employee responsibilities for electrical safety; Arc flash equipment labels and incident energy information.

Electrical Theory and Principles 10 items

Our study plan for this topic: Ohm's Law and Watt's Law formulas and calculations; Series, parallel, and combination circuit analysis; Alternating current fundamentals: sine waves, frequency, and waveform values (peak, RMS, instantaneous); Power factor, true power, and apparent power (VA) calculations; Inductance, capacitance, inductive reactance, and capacitive reactance; Impedance calculations in AC circuits; Atomic structure, electron theory, conductors, semiconductors, and insulators; Electrical power calculations: kilowatts, kVA, horsepower, and efficiency.

Testing and Troubleshooting 7 items

Our study plan for this topic: Selecting and using test instruments (multimeters, clamp-on ammeters, non-contact voltage testers); Test instrument safety ratings and overvoltage categories (CAT I–IV); Verifying absence of voltage and operation verification procedures (NFPA 70E 110.6, 120.6); Wire resistance and voltage drop calculations using Ohm's Law and NEC Chapter 9 tables; Continuity, insulation-resistance, and voltage testing with the appropriate test instrument; Selecting and Using Test Instruments; General Requirements for Electrical Safety-Related Work Practices; Establishing an Electrically Safe Work Condition.

General Code Requirements 15 items

Our study plan for this topic: Purpose and scope of the NEC (practical safeguarding, what is and is not covered); Authority having jurisdiction (AHJ) roles, approval, listing, and labeling of equipment; Key NEC definitions and field terms versus NEC terms (Article 100 terminology); Working space and clearance requirements around electrical equipment (depth, width, height, conditions 1-2-3); Guarding of live parts and minimum clearance of live parts (elevation, enclosure types, warning signs); Electrical connections, conductor materials, splices, terminals, and temperature limitations; Equipment markings, arc-flash hazard warnings, and identification of disconnecting means; Requirements for Electrical Installations.

Wiring and Protection 18 items

Our study plan for this topic: Branch circuit ratings, conductor sizing, and load limits (Article 210); Feeder conductor sizing and overcurrent protection requirements (Article 215); Service conductor requirements, clearances, and wiring methods (Article 230); Grounding electrode system types, installation, and sizing (Article 250 Part III); Equipment grounding conductors and bonding jumper sizing and methods (Article 250 Parts IV-V); Overcurrent protective device types, ratings, and locations (Article 240); GFCI, AFCI, and ground-fault protection of equipment requirements; Surge-protective devices (SPDs) and surge arrester installation and ratings (Article 242).

Selects and Installs Cabinets, Boxes, Fittings, Conduit 16 items

Our study plan for this topic: Conduit fill calculations and conductor count limits (NEC Chapter 9 Table 1 percentages); Box fill calculations and volume requirements per conductor (NEC 314.16); Cabinet and cutout box installation requirements including wire-bending space and gutter width; Conduit bending methods — 90° stubs, offsets, saddle bends, back-to-back, and multi-shot bends; Securing and supporting requirements for conduit types (RMC, IMC, EMT, PVC, FMC, LFMC, LFNC); Selection of conduit type by application — permitted and not permitted uses for metallic and nonmetallic raceways; Underground installation requirements including minimum cover depths by wiring method; Cable wiring methods — permitted uses, securing intervals, and fitting requirements for NM, MC, AC, SE, UF, and other cable types.

Equipment for General Use 10 items

Our study plan for this topic: Motor branch-circuit conductor sizing and ampacity requirements; Motor overload protection selection and ratings; Motor branch-circuit short-circuit and ground-fault protective device maximum ratings; Motor controllers: marking, ratings, and disconnecting means; Transformer overcurrent protection, sizing, and calculations; Luminaire installation requirements and location restrictions; Receptacle ratings, grounding types, and replacement requirements; Switchboards, switchgear, and panelboard installation and labeling.

Special Occupancies and Special Equipment 8 items

Our study plan for this topic: Hazardous location classification — Class I, II, and III Divisions and Zone systems; Wiring methods and sealing requirements for hazardous (classified) locations; Health care facility wiring, grounding, and essential electrical systems; Swimming pools, fountains, spas, and similar installations — GFCI protection, bonding, and equipotential planes; Solar PV systems, wind electric systems, and fuel cell systems installation requirements; Elevators, escalators, cranes, hoists, and similar lifting equipment electrical requirements; Mobile homes, manufactured homes, recreational vehicles, and park trailers electrical supply and wiring; Special occupancy installations — marinas, agricultural buildings, theaters, assembly occupancies, motor fuel dispensing facilities, and temporary installations.

Special Conditions and Communication Systems 2 items

Our study plan for this topic: Fire alarm system wiring methods — NPLFA and PLFA circuits (NEC Article 760); Fire alarm cable types, listings, and substitution hierarchy (FPLP, FPLR, FPL, NPLFP, NPLFR, NPLF); Fire alarm system power sources, branch circuit requirements, and overcurrent protection; NFPA 72 initiating devices — heat detectors, smoke detectors, and manual fire alarm boxes (selection, spacing, and location); NFPA 72 notification appliances — audible and visual requirements, public and private mode, sleeping area; Emergency communications systems (ECS) — one-way and two-way systems, in-building EVACS, mass notification, and area of refuge; Supervising station alarm systems — central station service, signal disposition, and record keeping (NFPA 72 Ch. 26); Emergency and legally required standby system wiring, transfer equipment, and testing requirements (NEC Articles 700 and 701).

3 questions

Sample 1 — Wiring and Protection

Question: You are a journeyman electrician installing service-entrance cables on the exterior of a building. At what maximum interval must the cables be supported by straps or other approved means?

  • A. 450 mm (18 in.)
  • B. 600 mm (24 in.)
  • C. 750 mm (30 in.)
  • D. 300 mm (12 in.)

Correct Answer: C

Per NEC 230.51(A), service-entrance cables shall be supported by straps or other approved means within 300 mm (12 in.) of every service head, gooseneck, or connection to a raceway or enclosure and at intervals not exceeding 750 mm (30 in.).

Reference: NEC 2023 Section 230.51(A)

Sample 2 — Selects and Installs Cabinets, Boxes, Fittings, Conduit

Question: What is the minimum conductor size for Type MV cable rated 8001–15,000 volts?

  • A. 8 AWG
  • B. 6 AWG
  • C. 2 AWG
  • D. 1 AWG

Correct Answer: C

Per NEC Table 315.12(A), the minimum conductor size for conductors rated 8001–15,000 volts is 2 AWG for copper, aluminum, or copper-clad aluminum. The table lists minimum sizes as: 2001-5000V = 8 AWG, 5001-8000V = 6 AWG, 8001-15,000V = 2 AWG, 15,001-28,000V = 1 AWG, and 28,001-35,000V = 1/0 AWG.

Reference: NEC 2023 Table 315.12(A)

Sample 3 — General Code Requirements

Question: A worker stands in the working space between two 480-volt switchboards that face each other, and both have exposed live parts. What is the minimum depth of working space required?

  • A. 3 ft
  • B. 4 ft
  • C. 5 ft
  • D. 6 ft

Correct Answer: B

Exposed live parts on both sides of the working space = Condition 3. Table 110.26(A)(1), 151-600 volts nominal to ground, Condition 3 = 4 ft (1.2 m).

Reference: NEC 2023 Table 110.26(A)(1)

Your first attempt is an inspection, not a final grade. The results page breaks your score down by outline topic, so you can see which areas need work. Compare it with the real exam's passing score, 75% correct, and keep practicing until you pass consistently.

  • Answer what you know first and bookmark the rest. Our practice exams let you bookmark and come back.
  • Work your bookmarks on the second pass.
  • Keep your pace. The real exam works out to about 2 minutes 44 seconds per question.
  • After each attempt, look up each missed question's reference in your book and read the section.

Questions 110 questions (100 scored, 10 unscored)
Time limit 5 hours
Passing score 75% correct
Books in the exam room Open book
Exam fee The exam fee for this exam is paid to the State.
  • Exams are graded immediately upon completion and results are automatically forwarded to the licensing authority.

Source: State of Alabama Electrical Contractors Board — Candidate Information Bulletin, AL CIB 2026.10.26 (Version 1.0, effective October 26, 2026). Check the bulletin before test day: fees and rules can change.