Georgia Master Plumber Class II (Unrestricted) Exam Practice Exam
Free Practice Exam
Test your knowledge with 10 questions from our pool of 20 free questions.
- 10 questions per attempt
- 30 minute time limit
- Unlimited attempts
- A new mix each time
- Instant results
Full Practice Exam
Complete exam simulation matching the real PSI test format.
- 140 questions (same as real exam)
- 420 minute time limit
- 12 topic areas covered
- 692 questions in pool
- Detailed explanations
Georgia Master Plumber Class II (Unrestricted) — Practice Exam
What's on the exam
Questions per topic, out of 140The real Georgia Master Plumber Class II exam has 140 questions. You get 420 minutes — 7 hours — to finish. Passing is a scaled score of 70 — the number of correct answers that converts to 70 varies by exam form.
This practice exam comes in two versions:
Free practice exam: 10 questions per attempt, drawn from a limited pool. You can retake it as many times as you want. It gives you a feel for question style and difficulty before you commit to anything.
Full practice exam (paid): 140 questions, 420-minute time limit — a mirror of the real test. Questions are pulled from a pool of 693+ items, so each attempt is different. You won't see the same exam twice. Questions are built around the exact topic areas from the official test provider. If you're serious about passing, this is where you prep.
Start with the free exam to calibrate. Then move to the full exam for real preparation.
The exam covers 12 topic areas. Here's what each one actually demands.
Comply with General Laws — 5 items. Know how the Georgia Construction Industry Licensing Board (GCILB) works: complaint procedures, license renewal, and what the board is authorized to do. You'll also need to know Georgia 811 underground utility location law — specifically when you must call, how far in advance, and what happens if you don't. ADA and ANSI accessibility questions test specific measurements, not general concepts. State water conservation law and ADA employment rules (reasonable accommodation, undue hardship, essential functions) round this out.
Comply with Regulations — 15 items. This is code-heavy. Know the Georgia State Plumbing Code and the Georgia State Amendments to the 2024 IPC and IFGC. Expect questions on OSHA 29 CFR 1926 — particularly confined space, trenching, and fall protection regulations. Understand Georgia's State Boiler Code requirements and when permits and inspections are required. The State Trenching Law gets its own subtopic, so treat it separately from OSHA trenching rules.
Work Planning/Organizing — 7 items. You must be able to read a drawing and compile a bill of materials — know what a quantity take-off is and how it works. Interpret nameplate data on pumps, water heaters, backflow preventers, and lift stations. Read and draw isometric diagrams for waste and water systems. Understand bar charts and critical path method (CPM) scheduling. Know the hierarchy of codes, manufacturer instructions, and regulations when they conflict.
Perform Pipe Cutting and Joining Activities — 10 items. Know the right tool for each pipe type: snap-type chain cutter and hydraulic cutters for cast iron, tubing cutters for copper, scissor cutters for plastic, hand or power pipe cutters for steel. Know joining methods — lead and oakum, rubber-type seals, and no-hub connectors for cast-iron soil pipe. Expect questions on rubber gasket specs (ASTM C564) and solvent cement specs (ASTM F656, ASTM B813).
Perform Plumbing Systems Installation Activities — 21 items. This is the largest section. Sizing and installing water supply and drainage systems will require you to read tables, apply grade requirements, and size pipe correctly. Gas pipe sizing from IFGC Table 402.4(2) using the longest-length and branch-length methods appears here. Know how to locate and mark penetrations in walls, ceilings, and floors. Fixture and fitting assembly questions test your ability to read and apply manufacturer instructions.
Perform System Testing Activities — 7 items. Know the correct test for each system: air, water, hydrostatic for water distribution; water, smoke, air, and peppermint for sanitary systems; air for gas lines. Know pressure requirements and gauge increments. Backflow preventer certification and potable water sterilization procedures are also tested — including how to obtain certification after sterilization.
Perform Maintenance and Repair Activities — 15 items. Gas leak detection using soapy water or a gas detector. Servicing gas appliances — burner adjustment, valve checks, venting. Electric water heater element replacement and controls. Locating and removing drain obstructions. Cleaning backwater valves. Repairing leaking faucets and valves. These questions are hands-on and procedural — know the steps.
Safety-Related Issues — 15 items. Relief valve sizing, pressure ratings, routing, and termination for water heaters and pressure vessels. Gas piping testing and support requirements. Backflow prevention identification. OSHA personal protective equipment rules, fall protection systems (guardrail, safety net, personal fall arrest), and hazard control for poisonous gases and trenching. Know 29 CFR 1926 sections on fall protection (§1926.502) cold.
Calculations — 5 items. You'll calculate pipe offsets using 45° constants, volume of cylinders and rectangular solids, water pressure and head (psi-to-feet conversion), grade and drop for drainage piping, and pipe capacity in gallons per foot. Bring a calculator and know your formulas — these are not estimation questions.
Comply with Business Laws — 15 items. Workers' compensation requirements, unemployment insurance, FUTA tax from Circular E (Pub. 15), sales and use tax, business licensing, and I-9 completion. Know the Circular E rules on who counts as an employee vs. a statutory employee or nonemployee.
Comply with Administrative Requirements — 15 items. Bonding types, liquidated damages clauses, insurance (liability, property damage, auto), cash flow and financing, bookkeeping, job cost estimating, bidding procedures, and contracts and purchase orders. These questions test business knowledge, not plumbing knowledge.
Plumbing System Design — 10 items. Select appropriately sized water heaters and boilers. Choose sump reservoirs. Identify specialty fixtures for hospitals, restaurants, prisons, and medical facilities. Select industrial and specialty piping — medical gas, compressed air, vacuum systems.
Question 1 — Gas piping outlet stub depth through finished wall
When locating a gas piping outlet stub in a finished wall, the unthreaded portion of the piping outlet must extend through the finished wall surface not less than:
- A. 1/2 inch
- B. 2 inches
- C. 1 1/2 inches
- D. 1 inch
Correct answer: D — 1 inch.
IFGC 2024 Section 404.16 states that unthreaded piping outlets must extend not less than 1 inch through finished ceilings and walls, and not less than 2 inches above floors, outdoor patios, and slabs. The "2 inches" answer (B) is the floor/slab requirement — candidates who mix those two numbers get this wrong. The outlet must also be secured, must not be placed behind doors, and must be in the room where the appliance is installed.
Source: International Fuel Gas Code 2024, Section 404.16
Question 2 — Ductless mini-split condensate drain requirement
A ductless mini-split system that produces condensation is being connected to a condensate drain line. In addition to trapping as required by the equipment manufacturer, what does the code specifically require for this type of equipment?
- A. A water-level detection device in the primary drain pan
- B. A cleanout fitting at the drain pan connection
- C. An in-line check valve in the drain line or a trap
- D. An auxiliary drain pan with a separate drain line
Correct answer: C — an in-line check valve in the drain line or a trap.
IPC 2024 Section 314.2.4.1 adds a requirement specific to ductless mini-split equipment: an in-line check valve in the drain line or a trap. Options A and D describe secondary/auxiliary protection measures under Section 314.2.3 — they apply to different equipment configurations, not to the mini-split-specific rule. Don't let the word "auxiliary" on option D mislead you.
Source: International Plumbing Code 2024, Sections 314.2.4 and 314.2.4.1
Question 3 — Trap-to-fixture vertical distance limit
During a remodel repair you must relower a lavatory trap that was reset too far below the fixture. Measured from the fixture outlet to the trap weir, the vertical distance shall not exceed:
- A. 30 inches
- B. 24 inches
- C. 36 inches
- D. 18 inches
Correct answer: B — 24 inches.
IPC 2024 Section 1002.1 sets two limits: vertical distance from fixture outlet to trap weir — not more than 24 inches; horizontal distance from fixture outlet centerline to trap inlet centerline — not more than 30 inches. Answer A (30 inches) is the horizontal limit. Swapping those two numbers is one of the most common mistakes on trap installation questions.
Source: International Plumbing Code 2024, Section 1002.1
Passing requires a scaled score of 70 (the raw cut varies by exam form).
Your first practice score is a diagnostic. If you score 60%, that tells you which topics to attack, not that you're going to fail. Look at performance by topic, not just total score. The exam has 15 items each in Regulations, Maintenance and Repair, Safety, Business Laws, and Administrative Requirements. A weak score in any one of those costs you points fast.
Scoring 70–74% on a practice exam isn't a comfortable margin. The real exam has time pressure, unfamiliar question phrasing, and no feedback. If you're hitting 70% on practice, you need more work — aim for 80%+ before you sit for the real thing.
Use the topic breakdown after each full practice attempt: find your two weakest areas, study those specifically, then retake. Repeat until your weak topics are no longer dragging your total score down.
Gas pipe sizing tables. IFGC Table 402.4(2) questions require you to pick the right column and row. Candidates use the wrong inlet pressure or confuse longest-length with branch-length method. Know both methods from IFGC Section 402.4.1 and 402.4.2 before exam day.
Mixing up code limits. The 24-inch vertical vs. 30-inch horizontal trap rule. The 1-inch wall vs. 2-inch floor gas outlet extension rule. The exam is built around these paired numbers. Read every question for which dimension is being asked.
OSHA 29 CFR 1926 specifics. Candidates know the concepts but miss the exact thresholds. Fall protection triggers at 6 feet in construction under §1926.502. Guardrail, safety net, and personal fall arrest systems each have distinct requirements — know them separately.
Business and administrative sections. Plumbers often underestimate these 30 combined items. Workers' comp, FUTA, Circular E employee classification rules, and bond types are straightforward — but only if you study them. Ignoring these sections costs you the exam.
Running out of time on calculations. Five calculation items doesn't sound like much, but candidates who can't quickly apply 45° offset constants or convert psi to feet of head burn time they need elsewhere. Practice the formulas from Mathematics for Plumbers and Pipefitters until they're automatic.
| Detail | Information |
|---|---|
| Total questions | 140 |
| Time limit | 420 minutes (7 hours) |
| Passing score | Scaled score of 70 |
| Number of topic areas | 12 |
| Free practice exam | 10 questions per attempt |
| Full practice exam pool | 692 questions |