Idaho Limited Electrical Sign Installer Practice Exam

40 questions 120 minutes 70% to pass 5 topics 3:00 per question Open book 204 questions in pool
Free Cheat Sheet Official Bulletin
Free

Free Practice Exam

$0

Test your knowledge with 10 questions from our pool of 20 free questions.

  • 10 questions per attempt
  • 30 minute time limit
  • Unlimited attempts
  • A new mix each time
  • Instant results
No account required.
Full Exam

Full Practice Exam

$4.95

Complete exam simulation matching the real PSI test format.

  • 40 questions (same as real exam)
  • 120 minute time limit
  • 5 topic areas covered
  • 204 questions in pool
  • Detailed explanations
Price per attempt. Never the same exam twice: each attempt draws a fresh set of questions.
Not sure which exam you need? Text us: (813) 582-5360
Texts preferred · 9am–9pm Central
Want a guided study plan? Study Course: topic briefs, 5 topic quizzes and this full exam. $59.95/month.
See the study course

Idaho Limited Electrical Sign Installer Practice Exam Guide

Built from the official PSI exam bulletin. View the bulletin

What's on the exam

Questions per topic, out of 40
2017 National Electrical Code, NFPA – Chapter 616
2017 National Electrical Code, NFPA – Chapter 211
2017 National Electrical Code, NFPA – Chapter 15
2017 National Electrical Code, NFPA – Chapter 35
2017 National Electrical Code, NFPA – Introduction3

This practice exam is built around the official content outline for the Idaho Limited Electrical Sign Installer exam: 2017 National Electrical Code, NFPA – Introduction, 2017 National Electrical Code, NFPA – Chapter 1, 2017 National Electrical Code, NFPA – Chapter 2, 2017 National Electrical Code, NFPA – Chapter 3, 2017 National Electrical Code, NFPA – Chapter 6.

There are two ways to practice. The free practice exam gives you 10 questions per attempt, and you can take it as many times as you like. The full practice exam gives you 40 questions on a 2 hours clock, with a new draw from our question bank each time.

5 topics

2017 National Electrical Code, NFPA – Introduction 3 items

Our study plan for this topic: Purpose and scope of the NEC (practical safeguarding of persons and property); Installations covered and not covered under NEC scope (90.2); Code arrangement and chapter organization (90.3); Mandatory vs. permissive rules and explanatory material (90.5); Authority having jurisdiction (AHJ) enforcement and special permission (90.4); Equipment examination, listing, and approval for safety (90.7); Wiring planning for future expansion and circuit limitations (90.8); Units of measurement and dual SI/inch-pound system (90.9).

2017 National Electrical Code, NFPA – Chapter 1 5 items

Our study plan for this topic: Key NEC definitions applicable to electrical sign installations (Article 100); Equipment approval, listing, and labeling requirements; Electrical connections, splices, and terminal temperature limitations; Working space and clearance requirements around electrical equipment; Guarding of live parts and enclosure type selection; Equipment marking requirements including arc-flash hazard warnings; Mechanical execution of work and equipment mounting standards; Conductor materials, sizes, and wiring integrity requirements.

2017 National Electrical Code, NFPA – Chapter 2 11 items

Our study plan for this topic: Grounding and bonding requirements (Article 250) — system grounding, grounding electrode systems, and equipment grounding conductors; Branch circuit requirements — ratings, conductor sizing, GFCI and AFCI protection, and required outlets (Article 210); Overcurrent protection — fuses, circuit breakers, standard ratings, and location requirements (Article 240); Branch-circuit, feeder, and service load calculations — lighting loads, demand factors, and dwelling unit optional calculations (Article 220); Outside branch circuits and feeders — conductor clearances, disconnecting means, and wiring methods for exterior installations (Article 225); Identification and use of grounded conductors — color coding, terminal identification, and polarity requirements (Article 200); Bonding methods for services, piping systems, and structural metal (Article 250, Part V); Grounding electrode types, installation, and conductor sizing (Article 250, Parts III and IV).

2017 National Electrical Code, NFPA – Chapter 3 5 items

Our study plan for this topic: General wiring installation requirements (Article 300); Conductor ampacity tables and temperature correction/adjustment factors (Article 310); Conductor types, insulation designations, and permitted uses by location; Conductors in parallel — requirements and restrictions; Outlet, device, pull, and junction box sizing and fill calculations (Article 314); Cabinets, cutout boxes, and wire-bending space requirements (Article 312); Conduit types — uses permitted, securing, supporting, and bending requirements (EMT, RMC, IMC, FMC, LFMC, PVC, LFNC); Cable assembly types — uses permitted and installation requirements (NM, MC, SE, USE, UF).

2017 National Electrical Code, NFPA – Chapter 6 16 items

Our study plan for this topic: Branch circuit requirements for electric signs and outline lighting systems; Disconnecting means location and lockout requirements for signs; Grounding and bonding of sign equipment and metal parts; Listing, marking, and labeling requirements for signs and retrofit kits; Enclosure construction requirements for signs and outline lighting; Neon secondary-circuit wiring over 1000 volts (GTO cable, conduit, spacing, and length limits); Ballasts, transformers, electronic power supplies, and Class 2 power source installation requirements; Electrode connections and neon tubing support requirements.

3 questions

Sample 1 — 2017 National Electrical Code, NFPA – Chapter 6

Question: You are laying out the electrical rough-in for a new single-story strip retail building that is accessible to pedestrians. The building contains three tenant spaces, and each tenant space has two separate pedestrian entrances. What is the minimum number of sign/outline lighting outlets that must be provided for this building?

  • A. 1
  • B. 6
  • C. 3
  • D. 2

Correct Answer: B

NEC 2017, Section 600.5(A) requires at least one outlet in an accessible location at EACH entrance to EACH tenant space for sign or outline lighting system use. With three tenant spaces having two entrances each, a minimum of six outlets is required. Each such outlet must be supplied by a branch circuit rated at least 20 amperes that supplies no other load.

Reference: NEC 2017 Section 600.5(A)

Sample 2 — 2017 National Electrical Code, NFPA – Chapter 2

Question: According to NEC 240.6(B), what is the ampere rating of an adjustable-trip circuit breaker that has external means for adjusting the current setting but does NOT have restricted access?

  • A. The minimum setting possible
  • B. The nominal rating printed on the breaker label
  • C. The setting at the time of installation
  • D. The maximum setting possible

Correct Answer: D

According to the National Electrical Code Handbook (Page 151), Section 240.6(B), the rating of adjustable-trip circuit breakers having external means for adjusting the current setting (long-time pickup setting), not meeting the requirements of 240.6(C) for restricted access, shall be the maximum setting possible.

Reference: NEC 2017

Sample 3 — 2017 National Electrical Code, NFPA – Chapter 1

Question: In a copper-clad aluminum conductor, the copper must form a minimum of what percentage of the cross-sectional area of a solid conductor or of each strand of a stranded conductor?

  • A. 25 percent
  • B. 5 percent
  • C. 15 percent
  • D. 10 percent

Correct Answer: D

NEC 2017, Article 100 defines Copper-Clad Aluminum Conductors as conductors drawn from a copper-clad aluminum rod in which the copper forms a minimum of 10 percent of the cross-sectional area of a solid conductor or each strand of a stranded conductor.

Reference: NEC 2017 Article 100 (Definition: Copper-Clad Aluminum Conductors)

Your first score is just a starting point. After every attempt, the results page shows how you did on each outline topic, so you can see what to work on next. Compare your score with the real exam's passing score, a minimum score of 70, and keep at it until you pass consistently.

  • Start with the questions you know. Go through the whole exam once and bookmark anything you're unsure about. Our practice exams let you bookmark and come back.
  • Circle back to your bookmarks on the second pass.
  • Keep an eye on your pace. The real exam works out to about 3 minutes per question.
  • Turn every miss into a lesson. After each attempt, look up each missed question's reference in your book and read the section.

Questions 40 questions
Time limit 2 hours
Passing score a minimum score of 70
Books in the exam room Open book
Exam fee $75
  • Your score is shown on screen at the end of the exam and a score report is provided, with a diagnostic report of strengths and weaknesses if you fail.
  • If you do not pass, you may retake the exam as many times as needed, paying an examination fee for each attempt.

Source: Examination Scheduling Procedures / Examination Guide (Idaho PSI Candidate Bulletin), Effective 7/9/2026. Check the bulletin before test day: fees and rules can change.

Reference books

4 books on the bulletin
As an Amazon Associate we earn from qualifying purchases.
10 free questions30 min · no account