Kansas City, MO Master Gas Pipe Fitter (ICC G33, 2018 IFGC) Practice Exam Guide
What's on the exam
Questions per topic, out of 75This practice exam follows the official content outline for the Kansas City, MO Master Gas Pipe Fitter (ICC G33, 2018 IFGC) exam: General Requirements, Water Heaters, Appliances and Equipment, Fuel Supply System Sizing, Combustion Air, Chimneys and Vents.
You have two ways to practice. The free practice exam gives you 10 questions per attempt, and you can retake it as often as you like. The full practice exam gives you 75 questions on a 3 hours clock, with a new draw from our question bank every attempt.
General Requirements 37 items
Our study plan for this topic: General Installation Requirements; Code Definitions and Terms; Plan Reading; Testing; Materials; Appliance Listing and Labeling Requirements; Permits and Permit Application Procedures; Inspection Types and Procedures.
Water Heaters 4 items
Our study plan for this topic: Installation of Water Heaters; Testing and listing standards for water heaters (ANSI Z21.10.1/CSA 4.1 and ANSI Z21.10.3/CSA 4.3); Water heaters used for combined potable water and space heating applications.
Appliances and Equipment 11 items
Our study plan for this topic: Requirements for Specific Appliances & Equipment; Clothes dryer exhaust duct installation and length limitations; Unvented room heater restrictions and oxygen-depletion safety systems; Vented wall furnace and floor furnace placement and clearance requirements; Cooking appliance clearances and prohibited locations; Water heater installation and dual-use (space heating) requirements; Gas-fired air-conditioning appliance clearances and refrigeration coil installation; Direct-fired industrial air heater (recirculating and nonrecirculating) location and air supply requirements.
Fuel Supply System Sizing 4 items
Our study plan for this topic: Service Distribution Pipe Sizing; Maximum gas demand calculation and total connected load; Allowable pressure drop and minimum appliance supply pressure; Sizing methods: longest length, branch length, and hybrid pressure; Low-pressure and high-pressure sizing tables for natural gas and LP-gas; Pipe sizing for CSST using equivalent hydraulic diameter (EHD); Gravity factor adjustments for specific gravity other than 0.60; Equivalent length allowances for fittings and valves.
Combustion Air 10 items
Our study plan for this topic: Combustion Air Source, Size of Ducts/Openings; Indoor combustion air volume requirements (standard method and known air-infiltration-rate method); Combining indoor spaces for combustion air (same story and different stories); Outdoor combustion air methods (two-permanent-openings and one-permanent-opening); Combination indoor and outdoor combustion air calculations; Mechanical combustion air supply requirements and appliance interlock; Louvers, grilles, and screens — net free area calculations and motorized louver interlock; Combustion air duct installation requirements.
Chimneys and Vents 9 items
Our study plan for this topic: Venting, Vent Connector, and Chimneys; Appliance venting categories and vent type selection (Table 503.4); Vent and chimney termination location requirements; Vent connector materials, sizing, slope, and clearances; Sizing of Category I appliance venting systems using Tables 504.2 and 504.3; Gas vent types (Type B, B-W, L) construction and installation requirements; Single-wall metal pipe vent requirements and limitations; Draft hoods, draft controls, and vent dampers.
Sample 1 — General Requirements
Question: As the master overseeing commissioning of a self-service LP-gas motor vehicle fuel-dispensing system (card lock type), you must verify the placement of the required emergency shutoff switch. Where must that switch be located relative to the dispensers?
- A. Within 100 feet, but not less than 25 feet
- B. Within 100 feet, but not less than 20 feet
- C. Within 75 feet, but not less than 20 feet
- D. Within 75 feet, but not less than 25 feet
Correct Answer: B
Per IFGC 2018 Section 412.9, Item 2, a self-service LP-gas dispensing system shall be provided with an emergency shutoff switch located within 100 feet (30 480 mm) of, but not less than 20 feet (6096 mm) from, the dispensers. The 75-foot/25-foot combination is the requirement for the emergency shutdown device at CNG motor fuel-dispensing facilities (Section 413.8) and is a common point of confusion.
Reference: IFGC 2018 Section 412.9, Item 2
Sample 2 — Appliances and Equipment
Question: What minimum clearance is required at the sides and bottom of a suspended-type unit heater to combustible materials when the unit has an internal draft hood?
- A. 12 inches at the sides, 6 inches at the bottom, and 1 inch above
- B. 18 inches at the sides, 12 inches at the bottom, and 6 inches above
- C. 6 inches at the sides, 12 inches at the bottom, and 18 inches above
- D. 24 inches at the sides, 18 inches at the bottom, and 12 inches above
Correct Answer: B
Per IFGC Section 620.4, suspended-type unit heaters shall be installed with clearances to combustible materials of not less than 18 inches at the sides, 12 inches at the bottom, and 6 inches above the top where the unit heater has an internal draft hood.
Reference: IFGC 2018 Section 620.4
Sample 3 — Combustion Air
Question: When using the Longest Length Method to size a residential gas piping system, what single measurement is used to determine the pipe size for EVERY section of the system?
- A. The length of each individual branch segment being sized
- B. The total combined length of all pipe segments in the system
- C. The length from the regulator to the nearest connected appliance
- D. The length from the point of delivery to the most remote outlet
Correct Answer: D
Per IFGC Appendix A, Section A.3.1, Step (4): 'Determine the length of piping from the point of delivery to the most remote outlet in the building/piping system.' Step (5) then states: 'This is the only length used in determining the size of any section of gas piping.' This single longest length is applied to every segment in the system, making the method conservative.
Reference: IFGC 2018 Appendix A, Section A.3.1
Treat your first attempt as a checkup, not a verdict. After every attempt, the results page breaks your score down by outline topic, so you can see which topics need work. Compare your score with the real exam's passing score, a minimum score of 70, and keep practicing until you pass consistently.
- Answer what you know first. Go through every question once, answer the ones you know, and bookmark the rest. Our practice exams let you bookmark and come back.
- Come back to your bookmarks. Work them out on your second pass.
- Watch your pace. The real exam works out to about 2 minutes 24 seconds per question.
- Look up every miss. After each attempt, find each missed question's reference in your book and read the section.
| Questions | 75 questions |
| Time limit | 3 hours |
| Passing score | a minimum score of 70 |
| Books in the exam room | Open book |
| Exam fee | $115 |
- Results for electronically administered examinations are available immediately after the exam is completed.
- You must wait 10 days before retaking a failed exam.
Source: Kansas City, Missouri Examination Information Bulletin (ICC Contractor/Trades), PUBLISHED November 10, 2025. Check the bulletin before test day: fees and rules can change.