Oklahoma Refinery Electrical Journeyman Exam Study Guide
This guide covers what you need for the Oklahoma Refinery Electrical Journeyman exam: the key facts from the official bulletin, the topics it tests, the reference books, sample questions with answers, and a plan to prepare. PSI gives the exam.
Oklahoma Refinery Electrical Journeyman Exam at a Glance
Here are the exam's key facts from the official bulletin:
| Questions | 100 questions |
| Time limit | 4 hours |
| Passing score | 70% correct |
| Books in the exam room | Open book |
| Exam fee | $92 |
On exam day
- You must bring one valid, unexpired, signature- and photo-bearing primary ID (state driver's license, state ID card, US passport, US military ID, US alien registration card, or Canadian government ID) matching the name you registered under.
- You should arrive at the examination site at least 30 minutes before your appointment.
- For this examination, NEC Handbooks and spiral-bound copies of the National Electrical Code are not allowed in the test center. References may be highlighted, underlined and indexed before the examination, but may not be written in before or during it. No additional papers may be brought in with the references. Only permanent tabs are allowed; temporary tabs such as Post-It notes must be removed. A reference downloaded from the Internet must be spiral bound, hole-punched in a binder, or stapled in the left-hand corner.
- References may be highlighted, underlined and indexed beforehand but not written in, and only permanent tabs are allowed (Post-It style temporary tabs must be removed).
- A silent, non-printing, non-programmable calculator without an alphabetic keyboard may be used in the examination center.
- Only approved items may be taken into the examination room and all personal belongings, including electronic devices, outerwear, hats, writing devices, food and drinks, must be placed in secure storage.
References you may bring
- NFPA 70 - National Electrical Code (2023 Edition, as revised and adopted by the Oklahoma Uniform Building Code Commission)
- International Residential Code for One-and Two-Family Dwellings (2018 or 2024 edition, with Oklahoma Revisions)
- Code of Federal Regulations - 29 CFR Part 1926 (OSHA) (with latest available amendments)
- Code of Federal Regulations - 29 CFR Part 1926 Selections by PSI (with latest available amendments)
- Ugly's Electrical References (any edition)
- Hazardous Locations (2005)
Scheduling, changes and retakes
- After state approval, you contact PSI to schedule, either online at https://test-takers.psiexams.com/okcontractors or by telephone at (855) 834-8750.
- You must be approved by the State before scheduling with PSI, and your eligibility does not expire.
- If you arrive after the examination start time, miss the appointment, cancel late, or lack proper ID, your registration is invalid and you forfeit the examination fee.
- Results are given immediately on screen, with a diagnostic strengths-and-weaknesses report for candidates who do not pass and an unofficial printed score report at the site.
- After a first failure you must wait 30 days to retest; electrical exam retests continue to require 30 days, while all other exams require 90 days from the second failure onward.
- If you pass the license exam, the Oklahoma State Construction Industries Board will issue your license.
Source: State of Oklahoma Electrical, Mechanical, Roofing, and Plumbing Examinations Candidate Information Bulletin, Effective 12/18/2025. Check the bulletin before test day: fees and rules can change.
What the Oklahoma Refinery Electrical Journeyman Exam Covers
The official content outline has 12 topics:
| Topic | Questions | Share of the exam |
|---|---|---|
| General Electrical Knowledge | 10 | 10% |
| Electrical Installation Requirements | 4 | 4% |
| Services, Feeders, and Branch Circuits | 6 | 6% |
| Overcurrent Protection | 6 | 6% |
| Grounding and Bonding | 10 | 10% |
| Conductors and Cables | 6 | 6% |
| Raceways and Boxes | 6 | 6% |
| Low Voltage, Alarms, Signaling Systems, and Communications | 4 | 4% |
| Lighting and Signs | 4 | 4% |
| Safety | 5 | 5% |
| Motors and Transformers | 4 | 4% |
| Hazardous Locations | 35 | 35% |
General Electrical Knowledge: Permits and Inspections; Preservation of Structural Integrity; Needs Analysis and Estimate; Voltage, Current, and Resistance in Series, Parallel, and Combination Circuits; Power Used in a Circuit; Power lost (called Heat Lost) in Any Circuit; Fundamental AC Theory; Fundamental Three-phase AC Theory.
Services, Feeders, and Branch Circuits: Services; Voltage Drop for Branch Circuits or Feeders; Services in Excess of 600 volts; Feeders; Outside Branch Circuits and Feeders; Branch Circuits; Space-heating, Snow-melting, and Pipe-heating Circuits; Air-conditioning and Refrigeration Equipment.
Conductors and Cables: Underground Conductors and Cables; Vertical Installations; Selecting Conductors; Armored Cable, Type AC; Metal-clad Cable, Type MC; Nonmetallic-sheathed Cable, Types NM, NMC, NMS; Service Entrance Cables, Types SE and USE; Underground Feeder and Branch Circuit Cable, Type UF.
Raceways and Boxes: General Raceway Requirements; General Box Requirements; Pull Boxes; Conduit Fittings; Type RMC (Rigid Metal Conduit); Type EMT (Electric Metallic Conduit); Type IMC (Intermediate Metal Conduit); Type RNC (Rigid Nonmetallic Conduit).
Low Voltage, Alarms, Signaling Systems, and Communications: Remote Control or Signaling Circuits; Communication Circuits; Equipment Operating at 50 volts or Less; Fiber Optics; Photovoltaics; Remote Controls; Fire Alarms; Circuit Wiring for an Emergency System.
Lighting and Signs: Fixture Installation; Fixture Grounding; Fixture Wiring; Fluorescent Fixtures; Fixture Construction Requirements; Recessed Fixtures; Lighting Systems that Operate at Less Than 30 volts; Neon Lighting and Electric Signs.
Safety: Job Site Sanitation; Responsibility for Providing Personal Protective Equipment; Excavation Safety; Emergency Action Plans; Safety Training Requirements; Ventilation; First Aid Kit Requirements; Use of Personal Protective Equipment.
Hazardous Locations: Hazardous Location Classifications; Hazardous Materials; Equipment used in Hazardous Locations; Ventilation and Seals; Underground Wiring; Fuel Dispensing Location Requirements.
How to Prepare for the Oklahoma Refinery Electrical Journeyman Exam
Start with the books. This is an open-book exam, so the references on the bulletin's list are your main study tool. Get the editions the bulletin names.
Learn where things are. Read the table of contents and the index of each book until you know where every major subject lives. On test day, finding an answer fast matters more than memorizing it.
Highlight the sections you use most. The exam facts above list the bulletin's rules on tabs and markings, so follow them exactly.
Take timed practice exams. The clock trains you to find answers at the pace the real exam needs: about 2 minutes 24 seconds per question.
Aim to pass more than once. One passing score can be luck. Several in a row means you're ready.
Reference Books for the Oklahoma Refinery Electrical Journeyman Exam
The references allowed in the examination center for this exam are the 2023 NEC (NFPA 70), the International Residential Code for One- and Two-Family Dwellings, 2018 or 2024 edition, with Oklahoma Revisions (the 2024 edition can be used starting 9/14/2026, and the 2018 edition is no longer allowed as of 12/14/2026), 29 CFR Part 1926 (OSHA) or the PSI selections version, Ugly's Electrical References (any edition), and Hazardous Locations, 2005.
Where to get them:
- NEC 2023
- OSHA 29 CFR 1926
- Ugly's Electrical References 2020
- IRC 2024
- Hazardous Locations
On Test Day
- Go through the whole exam first. Answer every question you know and bookmark the ones you don't. Every exam lets you come back to bookmarked questions, but some lock the questions you've seen once you take a break, so work your bookmarks before any break.
- Then go back to your bookmarks and work them out.
- Don't let one question eat your time. You have 4 hours for 100 questions, which is about 2 minutes 24 seconds per question.
- Before you finish, answer anything you skipped. A blank can't earn a point.
Study Tips
Take this practice exam several times. The goal is to consistently clear your exam's passing score — often around 70–75% — so passing feels routine before you walk into the real test.
Our practice exam is specifically designed to mimic the testing conditions at all exam centers. While untimed PDF study guides might help with studying, they don’t prepare you for the challenge of managing your time during an actual test.
If you've actually studied, an option full of unfamiliar terms is usually a distractor. A choice you don't recognize at all is rarely the correct one.
On an open-book exam, the winners aren't the smartest people in the room — they're the fastest at finding answers. Buy the required book, practice with it open, and tab and highlight each section the first time a question sends you there. Learn the index and table of contents until you can land on any topic in seconds. That speed is what separates a pass from a fail.
Before reading the answer choices, try to predict the correct answer based solely on the question. Your thinking is sharpest at this moment, before distractors cloud your judgment. Then scan the choices for your prediction—if it's there, you're likely right. A quick check of the remaining options is still worthwhile, but trust your instinct.
Sample Oklahoma Refinery Electrical Journeyman Practice Questions
These questions come from our practice question bank, each with its answer and reference.
Sample 1 — Services, Feeders, and Branch Circuits
Question: A building or other structure served shall be supplied by only ______ service(s) unless otherwise permitted by special conditions, occupancies, capacity requirements, or different characteristics.
- A. one
- B. two
- C. three
- D. four
Correct Answer: A
NEC 230.24 (NEC 2023: 230.2) states that a building or other structure served shall be supplied by only one service unless permitted in 230.24(A) through (D) (NEC 2023: 230.2(A) through (D)), which cover special conditions such as fire pumps, emergency systems, special occupancies, capacity requirements exceeding 2000 amperes, or different voltage/frequency/phase characteristics.
Reference: NEC 2023 Section 230.2
Sample 2 — Overcurrent Protection
Question: An adjustable-trip circuit breaker has external means for adjusting the current setting but does NOT have restricted access to the adjusting means. What is the ampere rating of this circuit breaker?
- A. The midpoint of the available adjustment range
- B. The nominal current rating printed on the frame
- C. The maximum setting possible on the adjustment
- D. The lowest setting possible on the adjustment range
Correct Answer: C
Per NEC 240.6(B), the rating of adjustable-trip circuit breakers having external means for adjusting the current setting (long-time pickup setting), not meeting the requirements of 240.6(C) for restricted access, shall be the maximum setting possible.
Reference: NEC 2023 Section 240.6(B)
Sample 3 — Conductors and Cables
Question: When conductors are installed in parallel, which of the following is NOT required for each paralleled conductor in the set?
- A. Same manufacturer and same production lot
- B. Same insulation type and same termination method
- C. Same size in circular mil area
- D. Same length and same conductor material
Correct Answer: A
Per NEC 310.10(G)(2), paralleled conductors must be the same length, same conductor material, same size in circular mil area, have the same insulation type, and be terminated in the same manner. There is no requirement that they be from the same manufacturer or production lot.
Reference: NEC 2023 Section 310.10(G)(2)
Sample 4 — Raceways and Boxes
Question: For device fill calculation in boxes, each yoke or strap containing one or more devices requires what volume allowance?
- A. Single volume allowance
- B. Double volume allowance
- C. Triple volume allowance
- D. No volume allowance
Correct Answer: B
Per NEC 314.16(B)(4), for each yoke or strap containing one or more devices or equipment, a double volume allowance in accordance with Table 314.16(B)(1) shall be made for each yoke or strap based on the largest conductor connected to a device(s) or equipment supported by that yoke or strap.
Reference: NEC 2023 Section 314.16(B)(4)
Why Practice Online Instead of With a PDF
A PDF shows you questions. It doesn't show you the clock. Our practice exams are timed and on a screen, so you practice finding answers under time pressure, not just reading them. Each attempt draws a new set of questions from our bank, and your results break the score down by outline topic so you know what to study next.
Start Practicing
Take the free Oklahoma Refinery Electrical Journeyman practice exam to see where you stand, then work through the topics that need attention. For the official rules, read the exam bulletin, and see the licensing board's website.