South Carolina · PSI

South Carolina - NASCLA-Accredited Trade Examination for Electrical Contractor Practice Exam

100 questions 270 minutes 75% to pass 9 topics 2:42 per question Open book 497 questions in pool
Free Cheat Sheet Official Bulletin
Free

Free Practice Exam

$0

Test your knowledge with 10 questions from our pool of 20 free questions.

  • 10 questions per attempt
  • 30 minute time limit
  • Unlimited attempts
  • A new mix each time
  • Instant results
No account required.
Full Exam

Full Practice Exam

$9.95

Complete exam simulation matching the real PSI test format.

  • 100 questions (same as real exam)
  • 270 minute time limit
  • 9 topic areas covered
  • 497 questions in pool
  • Detailed explanations
Price per attempt. Never the same exam twice: each attempt draws a fresh set of questions.
Not sure which exam you need? Text us: (813) 582-5360
Texts preferred · 9am–9pm Central
Want a guided study plan? Study Course: topic briefs, 9 topic quizzes and this full exam. $59.95/month.
See the study course

South Carolina - NASCLA-Accredited Trade for Electrical Contractor Practice Exam Guide

Built from the official PSI exam bulletin. View the bulletin

What's on the exam

Questions per topic, out of 100
General Code Requirements17
Wiring and Protection17
Wiring Methods & Materials16
General Equipment Use13
Electrical Theory and Principles11
Safety9
Project Design & Management8
Special Occupancies, Special Equipment, and Special Conditions8
Communication Systems1

This practice exam follows the official content outline for the South Carolina - NASCLA-Accredited Trade for Electrical Contractor exam: Project Design & Management, Safety, Electrical Theory and Principles, General Code Requirements, Wiring and Protection, Wiring Methods & Materials, General Equipment Use, Special Occupancies, Special Equipment, and Special Conditions, Communication Systems.

You have two ways to practice. The free practice exam gives you 10 questions per attempt, and you can retake it as often as you like. The full practice exam gives you 100 questions on a 270 minutes clock, with a new draw from our question bank every attempt.

9 topics

Project Design & Management 8 items

Our study plan for this topic: Electrical load calculations and service sizing; Blueprint and schematic reading for electrical systems; Project scheduling and sequencing of electrical work; Material takeoffs and quantity estimation; Electrical system design compliance with NEC requirements; Job cost estimating and bidding; Coordination with other trades and project stakeholders; Permit and inspection processes for electrical projects.

Safety 9 items

Our study plan for this topic: Personal protective equipment (PPE) requirements for electrical work; Lockout/tagout procedures for electrical energy control; Electrical hazard identification and arc flash safety; OSHA regulations applicable to electrical contractors; Safe work practices for energized and de-energized electrical systems; Ladder and scaffold safety for electrical installations; Confined space entry procedures; Fire prevention and extinguisher use on job sites.

Electrical Theory and Principles 11 items

Our study plan for this topic: Ohm's Law and voltage, current, resistance relationships; Series and parallel circuit analysis; Power and energy calculations (watts, kilowatts, horsepower conversions); AC vs DC fundamentals and waveform characteristics; Capacitance and inductance in AC circuits; Power factor and reactive power concepts; Electromagnetism and transformer principles; Three-phase power calculations and configurations.

General Code Requirements 17 items

Our study plan for this topic: NEC Article 90 purpose, scope, enforcement, and arrangement of the Code; Article 100 definitions used across the Code (accessible, readily accessible, approved, listed, labeled, bonding, grounded, etc.); 110.2-110.3 approval, listing, and use of equipment per instructions; 110.4-110.7 voltages, conductor material, insulation integrity; 110.9-110.10 interrupting rating and short-circuit current ratings; 110.11-110.13 deteriorating agents, workmanship, mounting and cooling of equipment; 110.14 electrical connections, terminal temperature ratings, and torque; 110.15-110.16 high-leg marking and arc-flash hazard warning labels.

Wiring and Protection 17 items

Our study plan for this topic: Grounding and bonding requirements for electrical systems; Overcurrent protection sizing and device selection; Branch circuit ratings and conductor ampacity; Ground fault circuit interrupter (GFCI) protection requirements; Arc fault circuit interrupter (AFCI) protection requirements; Surge protection device requirements; Conductor insulation types and wiring methods; Service entrance and feeder protection requirements.

Wiring Methods & Materials 16 items

Our study plan for this topic: Cable and conduit types and their permitted uses; Conduit fill calculations and conductor allowances; Installation requirements for NM, MC, and AC cable; Raceway installation and support requirements; Wiring methods in specific occupancies and environments; Conductor sizing, insulation types, and temperature ratings; Protection requirements for wiring methods (physical damage, wet locations); Boxes, fittings, and enclosure requirements for wiring systems.

General Equipment Use 13 items

Our study plan for this topic: Safe use and handling of electrical tools and equipment; Equipment ratings and selection for electrical applications; Grounding and bonding of electrical equipment; Overcurrent protection requirements for equipment; Equipment installation and mounting requirements; Disconnecting means for electrical equipment; Equipment listing and labeling requirements; Working clearances and access around electrical equipment.

Special Occupancies, Special Equipment, and Special Conditions 8 items

Our study plan for this topic: Hazardous locations classification (Class I, II, III; Divisions 1 and 2); Wiring methods and equipment permitted in hazardous locations; Health care facilities electrical requirements (hospitals, nursing homes); Places of assembly occupancy wiring requirements; Agricultural buildings and structures electrical installations; Electric signs, outline lighting, and associated wiring; Swimming pools, fountains, and similar installations; Temporary installations and construction site wiring requirements.

Communication Systems 1 item

Our study plan for this topic: Installation requirements for communication wiring and cables; Article 800 telephone and telegraph systems; Coaxial cable installation and grounding; Network-powered broadband communications systems; Optical fiber cables and raceways; Bonding and grounding of communication systems; Separation from power conductors; Communication circuit protectors and surge protection.

3 questions

Sample 1 — General Code Requirements

Question: A worker stands in the working space between two 480-volt switchboards that face each other, and both have exposed live parts. What is the minimum depth of working space required?

  • A. 3 ft
  • B. 4 ft
  • C. 5 ft
  • D. 6 ft

Correct Answer: B

Exposed live parts on both sides of the working space = Condition 3. Table 110.26(A)(1), 151-600 volts nominal to ground, Condition 3 = 4 ft (1.2 m).

Reference: NEC 2023 Table 110.26(A)(1)

Sample 2 — Wiring and Protection

Question: You are called to a commercial facility where a new HVAC system is being installed. The air-conditioning equipment includes a hermetic refrigerant motor-compressor. According to the NEC, which article's Part IV should you reference for determining the conductor sizing requirements for this air-conditioning load on the feeder?

  • A. Article 440, Part IV
  • B. Article 210, Part IV
  • C. Article 430, Part IV
  • D. Article 424, Part IV

Correct Answer: A

Per NEC 220.50(B), the conductor sizing requirements specified in Part IV of Article 440 shall be used to determine air-conditioning loads for hermetic refrigerant motor-compressors.

Reference: NEC 2023 Section 220.50(B)

Sample 3 — Wiring Methods & Materials

Question: At what minimum distance from each outlet box, junction box, or conduit termination must FMC (Flexible Metal Conduit) be securely fastened?

  • A. 6 inches
  • B. 12 inches
  • C. 18 inches
  • D. 36 inches

Correct Answer: B

Per NEC 348.30(A), FMC shall be securely fastened in place by an approved means within 300 mm (12 in.) of each box, cabinet, conduit body, or other conduit termination.

Reference: NEC 2023 Section 348.30(A)

Treat your first attempt as a checkup, not a verdict. After every attempt, the results page breaks your score down by outline topic, so you can see which topics need work. Compare your score with the real exam's passing score, 75 correct answers out of 100 scored questions, and keep practicing until you pass consistently.

  • Answer what you know first. Go through every question once, answer the ones you know, and bookmark the rest. Our practice exams let you bookmark and come back.
  • Come back to your bookmarks. Work them out on your second pass.
  • Watch your pace. The real exam works out to about 2 minutes 27 seconds per question.
  • Look up every miss. After each attempt, find each missed question's reference in your book and read the section.

Questions 100 scored questions plus up to 10 unscored experimental questions that count against your time
Time limit 270 minutes
Passing score 75 correct answers out of 100 scored questions
Books in the exam room Open book
Exam fee $116
  • Results are given immediately on screen, with a performance summary for passers and a printed diagnostic report for those who fail.
  • Each classification examination (except Burglar and Fire Alarm) may be taken only twice in a 12-month period and thereafter only once in six months, and a passed exam may not be retaken.

Source: Commercial Contractor Candidate Information Bulletin, Updated 9/15/2026. Check the bulletin before test day: fees and rules can change.

10 free questions30 min · no account