South Carolina · PSI

South Carolina Water and Sewer Plants Practice Exam

50 questions 180 minutes 70% to pass 6 topics 3:36 per question Open book 290 questions in pool
Free Cheat Sheet Official Bulletin
Free

Free Practice Exam

$0

Test your knowledge with 10 questions from our pool of 20 free questions.

  • 10 questions per attempt
  • 30 minute time limit
  • Unlimited attempts
  • A new mix each time
  • Instant results
No account required.
Full Exam

Full Practice Exam

$9.95

Complete exam simulation matching the real PSI test format.

  • 50 questions (same as real exam)
  • 180 minute time limit
  • 6 topic areas covered
  • 290 questions in pool
  • Detailed explanations
Price per attempt. Never the same exam twice: each attempt draws a fresh set of questions.
Not sure which exam you need? Text us: (813) 582-5360
Texts preferred · 9am–9pm Central
Want a guided study plan? Study Course: topic briefs, 6 topic quizzes and this full exam. $59.95/month.
See the study course

South Carolina Water and Sewer Plants Practice Exam Guide

Built from the official PSI exam bulletin. View the bulletin

What's on the exam

Questions per topic, out of 50
General Plant Construction20
Excavating and Grading8
Concrete6
Concrete - Reinforcing Steel6
Miscellaneous Engineering - Design Elevations6
Safety - Code of Federal Regulations4

This practice exam is built around the official content outline for the South Carolina Water and Sewer Plants exam: Safety - Code of Federal Regulations, General Plant Construction, Concrete, Concrete - Reinforcing Steel, Excavating and Grading, Miscellaneous Engineering - Design Elevations.

There are two ways to practice. The free practice exam gives you 10 questions per attempt, and you can take it as many times as you like. The full practice exam gives you 50 questions on a 3 hours clock, with a new draw from our question bank each time.

6 topics

Safety - Code of Federal Regulations 4 items

Our study plan for this topic: Excavation and trench safety requirements (cave-in protection, sloping, shoring, and shields); Confined space entry procedures and permit-required confined space programs; Fall protection systems (guardrail systems, personal fall arrest systems, and safety nets); Fire protection and prevention on construction sites (extinguisher ratings, flammable liquid storage, and ignition hazard controls); Electrical safety (ground-fault protection, grounding, wiring design, and working clearances); Occupational health and environmental controls (permissible exposure limits, noise, ventilation, and medical/first aid services); Underground construction safety (air monitoring, ventilation, gassy operations, and emergency provisions); Personal protective equipment selection, use, and employer payment requirements.

General Plant Construction 20 items

Our study plan for this topic: Trench excavation methods, equipment selection, and soil conditions; Pipe bedding requirements and laying conditions (Types 1–5); Ductile iron pipe joint assembly (push-on, mechanical, and flanged joints); Backfill procedures, compaction standards, and material requirements; Hydrostatic pressure testing and leakage allowances for water mains; Pipeline disinfection methods (tablet, continuous-feed, and slug); Thrust restraint methods (thrust blocks, restrained joints, and tie rods); Manhole construction, barrel setting, and vacuum testing.

Concrete 6 items

Our study plan for this topic: Concrete mixture design and proportioning (w/cm ratio, strength requirements, exposure categories); Properties of fresh concrete (workability, consistency, bleeding, air entrainment); Concrete durability (freeze-thaw resistance, sulfate attack, permeability, abrasion/erosion); Placing, finishing, and consolidation of concrete (subgrade preparation, formwork, depositing methods); Curing methods and materials (wet curing, curing compounds, duration, temperature requirements); Portland and blended cements and supplementary cementitious materials (types, properties, SCMs); Concrete imperfections and volume changes (cracking types, drying shrinkage, plastic shrinkage, remedies); Hot and cold weather concreting (temperature effects, precautions, strength development).

Concrete - Reinforcing Steel 6 items

Our study plan for this topic: Purpose of reinforcing steel in concrete (tension, compression, shear resistance); Reinforcing bar sizes, grades, and ASTM specifications; Deformed bar identification markings and grade marks; Standard hooks, bend shapes, and fabrication tolerances; Concrete cover requirements and placement tolerances; Types of splices: lap, mechanical, and welded; Bar supports: types, selection, and placement; Unloading, storing, handling, and hoisting reinforcing bars at the jobsite.

Excavating and Grading 8 items

Our study plan for this topic: Reading and interpreting survey stakes (cut, fill, slope stakes); Plan reading (grading plans, profile sheets, cross sections, contour lines, station numbers); Grade setting procedures (boots, hubs, swedes, string lines, eye levels); Laser levels and GPS equipment for grade control; SC 811 underground utility locate requirements and procedures; Trench safety (shoring, shields, sloping, depth requirements); Soil compaction methods, testing, and standards; Trenching and pipe laying (water and sewer lines, bedding, backfill).

Miscellaneous Engineering - Design Elevations 6 items

Our study plan for this topic: Reading and interpreting grading plans, contour lines, and lot pad elevations; Reading profile sheets and plan-and-profile drawings for underground utilities and pipe elevations; Reading road survey stakes (cut stakes, fill stakes, slope stakes) and surveyor notation; Interpreting street cross-section drawings including subgrade, aggregate base, and pavement elevations; Setting grade stakes and hubs using cut/fill calculations from surveyor information; Using laser levels and direct-reading rods to establish and verify design elevations; Reading and staking contour plans for finished grade elevations; GPS-based grade control and design elevation monitoring on grading equipment.

3 questions

Sample 1 — General Plant Construction

Question: Before installation, valves are checked for direction of opening, freedom of operation, cleanliness of ports and seating surfaces, and tightness of all bolts and nuts. Which fasteners are excepted from the tightness check and adjusted only on the manufacturer's recommendation?

  • A. Bonnet bolts on gate valves
  • B. Seat-adjusting bolts in butterfly valves
  • C. Flange bolts at valve end connections
  • D. Packing gland nuts on gate valves

Correct Answer: B

Per the DIPRA Installation Guide, Section 4.1, all bolts and nuts should be checked for proper tightness 'with the exception of seat-adjusting bolts or screws in butterfly valves, which should be adjusted only on the manufacturer's recommendation.' Adjusting these fasteners in the field can destroy the factory seat setting.

Reference: DIPRA Installation Guide for Ductile Iron Pipe, Page 64 (Section 4.1 Inspecting Valves)

Sample 2 — Excavating and Grading

Question: You are rough excavating a highway cut section that has dirt shoulders standing higher than the road subgrade. The cut has reached the shoulder grade, and your operators have moved inside the shoulders to continue cutting down to road subgrade. How should the vertical choker face be left until the subgrade is fine trimmed?

  • A. Undercut 0.05 foot for base material
  • B. Trimmed to final line and compacted
  • C. Left full by a couple of tenths
  • D. Cut on a 1:1 batter down to subgrade

Correct Answer: C

Per the Excavation and Grading Handbook, Chapter 11 (Chokers), once the highest grade in a cut area (the shoulder grade) is reached, equipment moves inside the shoulders and cuts to road subgrade, but the choker face must be left full by a couple of tenths until the subgrade is fine trimmed; then the choker face is fine trimmed. An overcut choker wastes expensive base material filling it back.

Reference: Excavation and Grading Handbook, Page 211 (Chapter 11 — Chokers section)

Sample 3 — Concrete

Question: You are the contractor placing a slab on ground inside a sewer plant building. The slab is lightly reinforced with welded-wire reinforcement, and your crew plans to consolidate it using a truss-type vibratory screed as the only means of consolidation. Beyond what slab thickness must you stop relying on surface vibration alone and add internal vibration?

  • A. 300 mm (12 in.)
  • B. 250 mm (10 in.)
  • C. 200 mm (8 in.)
  • D. 150 mm (6 in.)

Correct Answer: B

Per Design and Control of Concrete Mixtures, Chapter 15 (Consolidation — External Vibration), vibratory screeds are used for consolidating slabs up to 250 mm (10 in.) thick, provided those slabs are unreinforced or only lightly reinforced (welded-wire fabric). For thicker or conventionally reinforced slabs, internal vibration or a combination of internal and surface vibration is recommended. The text also notes surface vibration is least effective along edges, so an internal vibrator should be used along edge forms immediately before the vibratory screed is applied.

Reference: Design and Control of Concrete Mixtures (17th ed.), Chapter 15 — External Vibration section, Page 328

Your first score is just a starting point. After every attempt, the results page shows how you did on each outline topic, so you can see what to work on next. Compare your score with the real exam's passing score, 35 correct answers out of 50 scored questions, and keep at it until you pass consistently.

  • Start with the questions you know. Go through the whole exam once and bookmark anything you're unsure about. Our practice exams let you bookmark and come back.
  • Circle back to your bookmarks on the second pass.
  • Keep an eye on your pace. The real exam works out to about 3 minutes per question.
  • Turn every miss into a lesson. After each attempt, look up each missed question's reference in your book and read the section.

Questions 50 scored questions plus up to 10 unscored experimental questions that count against your time
Time limit 3 hours
Passing score 35 correct answers out of 50 scored questions
Books in the exam room Open book
Exam fee $78
  • Results are given immediately on screen, with a performance summary for passers and a printed diagnostic report for those who fail.
  • Each classification examination (except Burglar and Fire Alarm) may be taken only twice in a 12-month period and thereafter only once in six months, and a passed exam may not be retaken.

Source: Commercial Contractor Candidate Information Bulletin, Updated 9/15/2026. Check the bulletin before test day: fees and rules can change.

10 free questions30 min · no account